Tender For miscellaneous items for hpb and liver transplant surgery ot - radiopaque gauze :-should be sterile gauze & made up of 100% cotton gauze fabric type ep 17- x ray detachable should be weaved x ray 100% barium sulphate or metal it should be lint free, non irritating, latex free, and tissue size:- 10*10 cm*12 ply lint free non pack size 1*4 pc., vircyl sutupac 1, 1-0, 2-0 ,3-0 ,4-0, cautery pincil size 9 , electro surgical cautery tip cleaner, micro suction tip canula, liver biopsy gun, c. arm camera cover, usg prob cabel and camera cover, trolley covers, mayo trolley covers, pounch- opsite drap pouch drape:- 2 incise film provides continuous broad-spectrum antimicrobial activity to help reduce the risk of surgical site contamination incise drape adheres to the operative site, creating a sterile surface at the beginning of surgery 360-degree pouch provides optimal fluid collection to minimize contact with fluid and helps reduce the risk of contamination to or team pouch allows for easy clean-up and saves time comes with tube and cord organizers. a clear, plastic, 360-degree fluid collection pouch with tube and cord organizers. size 30*30 cm, steridrip (basic surgical pack), inj. methylene blue 1.0% 10ml ampoule, inj. albumin 5% (100ml), inj. calcium chloride (100 mg/ml), inj. diltiazem (5 mg/1ml, inj. phenylephrine (10mg/1ml) in ampoule size, inj. dns 500ml (double layered sterile plastic polybag), inj. dns 500 ml ( in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 500 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), inj. ns 1000 ml (in sterile double layered sterile plastic polybag), 0.33 ns (double layered sterile plastic polybag), 0.33 dns (double layered sterile plastic polybag), 3% ns (double layered sterile plastic polybag), inj gelofusion 500ml, single arterial & cvp pressure transducer ( compatible with edwards continuous cardiac output monitor ) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 2 three way stopcocks it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern. it should have a flow rate of 3 +/- 1 ml/hr under 300 mm hg iv bag pressure. should be usfda approved., arterial catheter 3fr-l-8cm usfda approved, gamjee roll, ky jelly, l-70 for fluid warmer set, d1-100 tubings for rapid fluid transfusion, hd catheter (size : 11.5 | 8.5 | 9 | 9.5 |10 | 10.5 ), et tube with suction port (size : 7 | 7.5 | 8 | 8.5), single pressure transducer with closed blood sampling system adult(vamp kit) one disposable pressure transducer having gold plated connector tip for best signal quality with flush device & vent stopcock, iv set, 1 shutoff valve, 60 patient pressure tubing along with inbuilt inline 12 cc reservoir & 2 self-sealing z-site sampling ports located 13 and 55 from patient for closed blood sampling; pole mountable. it should have special hood to reduce contamination risk. gold-plated connector wires for high-fidelity signal transmission. available with a snap-tab flush device that can be easily gripped and stretched 360 to quickly and easily flush the system and generate a square-wave test pattern, patient dress anti-bacterial ,anti-virus and anti-fungi :- fabric should be effective against bacteria , viruses, fungi, absorbency factor of less than 1 sec as per aatcc-79.has moisture wicking factor of 5 sec as per aatcc 197, fabric made up of 94% polyester ,6% spandex and 180 gsm +/-5% , free from toxin substances , breathable , skin friendly, antiseptic property ,should be iso 13485, cdsco & ce approved. size :- small to xl, pressure
Tender For corrigendum : procurement of spares for mig-29 upg aircraft - air hq/cpf-842/hqmc/mig-29upg/25-26/r25105/pur - signal transducer, control relay box kpcy 80 d, dc relay box (30e), ac relay box (81e), signal processor "baget-55-04. 07", lighting control unit, unit, system warning devices of m number
Tender For corrigendum : tender for supply of vao card , door hatch sensor , vdmc , serial expension card , vrtu fan chassis , 12v power supply for vrtu , 5v power supply for vrtu , 16 slot vme chassis system , serial card rs232+rs485 tab 5 , marine isolator , battery pack for ups , ruggedized , 2.4kw dc ups power unit , keyboard , rugged panel mount 2 in trackball , gauge 48 mm 0 to 10 bar , gauge 48mm 0 to 150 c , gauge 48mm 0 to 750 c , gauge 72mm 0 to 10 bar , gauge 72mm 0 to 1250 rpm , gauge 72mm 0 to 1250 rpm with backlit , gauge 96 mm 0 to 250 rpm , gauge 96 mm 0 to 250 rpm with backlit , gauge 96 mm 20 to 40deg , top mount level transmitter normal temp , side mount leval transmitter normal temp , top leval transmitter high temp for bilge , top leval transmitter ht ss316 , side leval transmitter high temp , flood switch , totaliser for flowmeter , pressure transducer (0-6 bar) , pressure transducer (0-10bar) , pressure transducer (0-250 bar) , portable operating unit , heat detector , lonisation smoke detector , optical smoke detector , marine mounting base , i.s lonisation smoke detector , i.s optical smoke detector , addressable base for is type sensors , i.s galvanic barrier , eeot - dial type for engine room , eeot gong for engine room , eeot- push button type for ops , vrtu power redundancy diode , rugged panel mount 20 1 in lcd monitor , network switch , sfp module for network switch , cctv external camera , trigger pcb transciver , modulator 25 kw transceiver , data interface & processing unit type 2 , vrtu console signal splitter (2 pole relay)
Tender For supply, installation and testing of electronic equipments - supply -ece lab equipments, single output regulated dcvariable power supply- input voltage: 230v / 50hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., dual output regulated dc variable power supply- input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator - frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v, digital ic trainer kit with breadboard - +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie- points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulseper press)., dc voltmeter(digital) - dc digital voltmeter - 3 digit led/lcd display, measurement range: 0 20 v dc,accuracy: class 0.5( 0.5 % full-scale), dc ammeter - dc ammeter digital - 3 digit led/lcd display, measurement range: 0 5 a dc,accuracy: class 0.5 ( 0.5 % full-scale), lvdttrainer kit - ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain gauge trainer kit - ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. instrumentation amplifiers with 3 digit display for strain / output voltage. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual., ask modulation and demodulation kit - message signal1:8-bit variable data,amplitude 5v. message signal 2:debounced data, amplitude low (0) and high (5 v). message signal 3:fixed data 25 khz, 12.5 khz, 6.25 khz, 3.12 khz,amplitude 5 v. carrier signal: sine wave, frequency 200 khz, amplitude 5 v. supply voltage (board): +12 v, +5 v dc. input voltage: 230 v ac, 50 hz. interface connectors: 2 mm banana socket., fpga trainer kit - must use industry-standard mid-range fpga device usb-jtag programmable, compatible with vivado ise (webpack). power supply: 5 v dc through usb or external adapter. on-board peripherals: leds, switches, push buttons, 7-segment display,clock source, gpio / pmod expansion ports, uart, vga / hdmi, usb- uart bridge, usb cable. user manual., measurement scale: a vertical steel meter scale, usually with (1mm) graduations, for precise deflection measurement., accessories: includes a set of slotted weights (e.g., (6times 50g) or similar sets) for incremental loading.
Tender For purchase of non-consumables for ece department - purchase, dual output regulated dc variable power supply input voltage: 230v/50 hz ac. output voltage: (0 30)v dc. output current: (0 2)a dc. protection circuit: over voltage, over current, and short-circuit protection. high efficiency: greater than 85%. low ripple and noise: less than 50 mv. digital display., function generator frequency range: 0.1 hz to 5 mhz. display: 4 to 6 digit led display. output waveforms: sine, triangle, square, pulse, ramp. amplitude: 0 20 vpp. rise time: 100 ns. distortion: 1% within specified frequency range. power supply: 230 v ac 10%, 50 60 hz. output amplifier protection: short-circuit and 15 v overload protection. dc offset: 0 to 10 v adjustable. attenuation: 0 to 60 db., dso (digital storage oscilloscope) bandwidth: 50 100 mhz. sampling rate: 1 gs/s. channels: 2 (minimum). power supply: 100 240 v ac, 50 60 hz. automatic measurements: vpp, vavg, vrms, frequency, period, vmax, vmin, rise time, fall time, +width, width, +duty, duty, etc. horizontal scale: 5 ns/div 50 s/div or equivalent. vertical resolution: 8 bits (2 channelssimultaneously). vertical sensitivity: 1 mv/div 10 v/div (at input). waveform math: +, , , , invert, fft, etc. waveform storage: 16 waveforms or equivalent. communication interface: usb host and usb interface. display: 7-inch color display or equivalent. input impedance: 1 m 2% || 20 pf. accessories: 2 passive probes (1x/10x)., digital ic trainer kit with breadboard +5 v dc, 1 a regulated power supply. 12 v dc / 15 v dc, 200 ma regulated power supply. solderless breadboard with minimum 840 tie points,power distribution buses. zif (zero insertion force) ic sockets to accommodate 8 or 16 pin ics. logic input and output leds for output monitoring. 16 buffered led outputs. 16 debounced switch inputs. variable clock generator: 0.5 hz to 50 hz. single pulse output: 100 ms (buffered, positive and negative outputs). one seven-segment display with 4 bcd inputs. built-in logic switches. manual clock: debounced push-button (one pulse per press)., lvdt trainer kit ac mains power supply: 230 v 10%, 50 hz. fixed regulated dc power supply: +5 v, 12 v / 500 ma. transducer: lvdt. lvdt displacement: 20 mm (40 mm total). displacement scale: linear 20 mm. displacement display: red color 3 digit led display. excitation frequency: 4 khz. excitation voltage: ac variable excitation voltage up to 5 v., strain guage trainer kit ac mains power supply: 230 v 10%, 50 hz metal foil strain gauge mounted on beam/cantilever. strain measurement under applied load. wheatstone bridge arrangement. signal conditioning and amplification circuit. instrumentation amplifiers with 3 digit display for strain / output voltage. zero and gain adjustment controls. provision for applying calibrated loads. table-top trainer with labelled panel. test points for signal measurement. built-in dc power supplies and wooden closed cabinet. supplied with patch cords and user manual.