Get complete information related to latest Pan Balance Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pan Balance Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pan Balance Tenders.
Tender For design, supply, erection, installation, testing, commissioning of pilot scale milk and milk product equipments on turnkey basis for research and development laboratory, products dairy
Tender For corrigendum : open tender document for e-procurement of laboratory equipment (soil, aggregates, cement, reinforcing bar, concrete test equipment, water, geo-textile and geogrid) for material testing laboratory of iahe - soil, unconfined compressive strengthcompression device with digital load frame: hydraulic proving ring, dial gauge vernier callipers, timer, oven, weighing balance, shear strength vane shear apparatus, grain size analysis as per is:2720 (part- iv)pipette apparatus (i) sampling pipette (ii) glass sedimentation tubes (iii) weighing bottles (iv) deleted (v) stirring apparatus (vi) sieves -2mm, 425umm , 75umm is sieves (vii) deleted, specific gravityhydrometer apparatus: two 1000 ml graduated cylinders, dispersing agent solution containing sodiumhexa-metaphosphate, dessicator and centimetre scale., shrinkage limit testfull set of equipments 1.) evaporating dish of porcelain, 2.) spatula and straight edge, 3.) balance-sensitive to 0.01 g minimum.4.) shrinkage dish. circular, porcelain or non-corroding metal dish, 5.) glass cup. 50-55 mm in diameter and 25 mm in height,6.) glass plates. two, 75x75 mm one plate of plain glass and the other prongs, 7.) thermostatically controlled oven,8.) wash bottle containing distilled water, 9.) graduate-glass, with capacity of 25 ml. 10.) mercury., sand equivalent value(i) graduated cylinder (ii) irrigator tube (iii) siphon assembly (iv) weighted foot assembly (v) measuring can (vi) sieve -4.75mm (vii) funnel (viii) 4- litre bottle (ix) flat pan (x) timing device (xi) sand equivalent shaker, ph test -electronic method(i) ph meter (ii) digital balance 300 gm capacity-sensitive 0.001gm (iii) 100ml glass beaker -3nos. (iv) volumetric flask-500ml -nos. (v) wash bottle-100 ml (vi) mortar with rubber covered pestle, aggregates, polished stone value (i) accelerated polish machine mounted on firm ,level and non resilient base of stone or concrete (ii) road wheel (iii) means for rotating road wheel (iv) means for bringing the surface of a rubber-tyred wheel of 20 cm diameter and 5 cm breadth to bear on the stone surface of the road wheel with a total load of 40 kg. (v) means to feed the sand and water at a uniform rate (vi ) means to feed the emery powder and water at uniform rate (vii) friction tester: is: 2386 part 4 as per specification of rrl uk (viii) 25 kg hard siliceous sand (ix) emery powder 5 kg, alkali aggregate reactivitymortar bar method: scales, weights, sieves, glass graduates, specimen moulds, mixing bowl, tamper, trowel, containers, length comparator, alkali aggregate reactivity chemical method:1. electronic balance2. pulveriser3. reaction container, reagents, glassware, petrographic examination 1. geological hammer2. petrographic microscope3. screen confirming to is sieve4. digital balance5. portable handheld cutting machine6. hand lens7. glass sides etc., deleterious material & organic impuritiessedimentation pipette: a watertight screw-topped glass jar, 1000 ml measuring cylinder, chemicals, containers, sieves, cement, soundness (autoclave apparatus)graduated glass cylinders, moulds, autoclave, length comparator, compaction (mortar cube vibrator), fineness (blaine air permeability apparatus), ph meter ( 2 in nos.), reinforcing bar (steel), reinforcing bar (steel) universal testing machine,to determine unit weight, yield strength,, proof stress, ultimate tensile strength, % elongation, bend and re-bend test, concrete test equipment, vibrating table 1mx1m(full set of equipments), needle vibrator ( 2 in nos.), permeability, dry shrinkage (shrinkage apparatus) ( 2 in nos.)(full set of equipments), air content (air entrainment meter apparatus)(full set of equipments), durability (rapid chloride ion permissibility apparatus), depth of penetration (water permeability apparatus) ( 2 in nos.)(full set of equipments), water, physical analysis of water, geo textile and geogrid, pull-out resistance of geotextile /geogrid
Tender For protection work at mata mansa devi corridor 5d, mdc, panchkula (balance work) (ch. to. re-development of mata mansa devi temple campus including water atm, entry hall, main gate, shakti chowk, retaining wall, stair case, corridor for temple and upasa
Tender For rectification works to meenachil river protecting the eroded right bank upstream of mutholi bridge ward 5 of mutholi panchayath balance work dsr 2016
Tender For supply of impact testing machine , crushing value testing machine , los angeles abrasion testing machine , flakiness index test gauges , elongation index test gauges , aggregate water absorption test set up , pycnometer as per requirement , is sieves for coarse aggregate gi sieves dia 300 mm , is sieves for fine aggregate brass sieves dia 200 mm , automatic sieve shaker 18 inch , bitumen extractor machine , vicat apparatus with deskpot , le-chatlier flasks , le-chatlier moulds , burette as per requirement , measuring cylinders , trowel small , trowel big , trays , sampling scoop , steel buckets as per requirement , cement cube moulds , automatic manual mortar mixer as per requirement , vibrating machine as per requirement , curing tank with controlled temperature , atterberg limits set-up liquid limit , atterberg limits set-up plastic limit , shrinkage limit apparatus with mercury , hydrometer analysis set-up range , free swell index apparatus , proctor testing equipment , core cutter test set up for in-situ density min. 6 mould with 01 hammer , sand replacement test set up for in-situ density , moisture container for omc by conventional method , hot air oven digital , physical balance electronic , rapid moisture meter , thermometer for measurement of room temperature , thermometer for measurement of temperature of bitumen, concrete , digital compression testing machine 2000 kn capacity semi automatic , digital compression testing machine 500 kn capacity , measuring tape 3m , measuring tape 10m , measuring tape 30m , measuring tape 50m , concrete cube moulds , concrete mixer 0.5 cum capacity electrically operated , concrete workability test by compaction factor test , ph meter , paint thickness meter elcometer ultrasonic digital , dial callipers , vernier callipers , digital micrometre , outside micrometres , depth gauge , density pot , density basket , slump test apparatus , electric platform balance 150 kg , electric panbalance 10 kg 1gm , precision balance 600 gm 0.1 gm , measuring flask , upv ultrasonic pulse velocity tester , rebound hammer , core falltering machine , flexural test appratus for beam , core cutting setup for conceret , rebar detector to locate reinforcement before core cutting
Tender For corrigendum : empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20