Tender For supply of dental and medical expendables - impression tray plastic assorted for upper and lower jaw , fox plane plastic , pmt set gdc , h2o2 , ss ivory band no 8 , ss ivory band no 1 , brush bristle polishing for contra angle handpiece , diamond round burs for air rotor , povidone iodine mouthwash 2 percent , mta , inter dental brush ns , patients bib , hexidine mouthwash , airrotor round bur carbide log shank , open coil spring , 019x 025 ss upper orthodontic archwire , 019x 025 ss lower orthodontic archwire , 021x 025 ss upper orthodontic archwire , 021x 025 ss lower orthodontic archwire , 016x 22 tma pkt of 10 upper , 016x 22 tma pkt of 10 lower , ortho separators , ortho modules , orthodontic adhesive , orthodontic bracket 022 mbt with 022 mbt molar tube , orthodontic mini implants , 016 niti rcos wire upper , 016 niti rcos wire lower , 016 x 22 niti rcos wire upper , 016 x 22 niti rcos wire lower , orthodontic study model box , ortho cal , orthodontic distal bender wire cincher , orthodontic wire sleeves , self ligating brackets with sequential wire set with compatible molar tubes damon type , skeleton anchorage system with screw and screw driver , irrigation needle pkt of 100 , gp solvent , sodium hypo chloride , edta gel , could mould seal , petroleum jelly , tungsten carbide fissure bur , sandpaper , dentine base opaque powder , metal finishing kit , polishing cake acrylic blue and brown , ceramic finishing kit , articulating paper , polishing buff metal , ceramic build up brush , cotton napkin , biostar sheets soft 2 mm , biostar sheets soft 1 point 5 mm , biostar sheets 1 mm hard , biostar sheets 0 point 5 mm pkt of 10 hard , cheek retractor with wings , ipr bur , teflon coated filling instrument set for composite filling bid number/ ( ( ) ): gem/2024/b/5662253 dated/* : 10-12-2024 bid document/ 1 1 / 41
Tender For supply ,installation &commissioning valve regulated lead acid stationary battery of 48v/ 200ah duly charged confirming to irs specification no.irs:s:93/96a with latest amendment.. the batte ry bank shall be supplied with stackable single cell of 2 volt-200ah and shall housed in metal tray to fac ilitate the required battery bank of 48volt i.e. each cell consist of 24 nos of stackable single of 2v-200a h along with necessary cell consisting links , nuts ,bolts,float insulation etc.make amraraja, hbl, exite, microtex or similar. warranty period : upto 30 months from the date of supply. [ warranty period: 3 0 months after the date of delivery ]
Tender For supply ,installation &commissioning valve regulated lead acid stationary battery of 48v/ 200ah duly charged confirming to irs specification no.irs:s:93/96a with latest amendment.. the batte ry bank shall be supplied with stackable single cell of 2 volt-200ah and shall housed in metal tray to fac ilitate the required battery bank of 48volt i.e. each cell consist of 24 nos of stackable single of 2v-200a h along with necessary cell consisting links , nuts ,bolts,float insulation etc.make amraraja, hbl, exite, microtex or similar. warranty period : upto 30 months from the date of supply. [ warranty period: 3 0 months after the date of delivery ]
Tender For the supply of veterinary equipments/machineries and instruments to the department of animal husbandry, govt. of up - name of equipment/instruments & specifications, automatic vaccinator bottle and vial attachment, pressure dose adjustment from 0.5ml to 5ml, luer lock needle nozzle with spare service kit., california mastitis test kit complete kit made of polypropylene with 4 mixing chambers and full grip handle including reagent, reagent dispenser and test colour standard chart, cattle crush tubular, made of g.i. pipe with outside diameter 60mm, height of front & back pillar 1980 mm, length & breadth of cattle crush be 1830 x 877 mm respectively. all four pillars should be provided holes at 75mm distance from bottom and be provided with round bars of 12mm diameter & 300 mm long, side pillars be joined by 2 tubular beams having 60 mm outside diameter, the insided distance between the two beams being 477 mm. the two sides of beams should be supported by two g.i. pipers of 48 mm diameter. lower side beam at 1223 mm height and upper side beam at 1700 mm height. circular 1 inch painted marking on all four pillars at the height of 450mm from below to indicate ground fill / fixation. cattle crush should also be provided with an adjustable gate to open sides. gate should consist one sliding g.i. pipe on two horizontal pipe of 60mm outer diameter to secure the neck of animal. two extra g.i. pipe 1.2 mtr. long of 60mm outer diameter should be provided for the backsides. two metalic loops on each side vertical rear pillar to control cattle from backside be provided. all the g.i. pipes used should be of isi mark a class with visible isi mark on every meter of pipe. all the joints should be electrically welded. (note-weight of the cattle crush should comply with the norms of the isi mark, a class gi pipe standard of specified diameters with variable maximum/minimum permissible limits)., chuck with key (orthopaedic) s.s. -304, 20cm, dehorning saw with detachable blades 45 cm, dog muzzels -standard, dressing forceps (s.s.-304) 25cm, dressing forceps (s.s.-304) 15cm, electric dehorner 30 cm length, portable electric sterilizer (ss 304), 30cmx15cmx20cm-1500 watt, enema pump (veterinary) reedis standard, firing iron set (conical,line,pin), forceps s.s. -304 15cm, forceps s.s. -304 17.5cm, forceps s.s. -304 20cm, formalin chamber with 100 formalin tablets non corrosive,standard, 20"x 8"x 8", gerlach/ buhner vulva suture instrument ss -304,18 cm, grays mouth gags for dogs ss-304, 11cm, grays mouth gags for dogs ss-304, 14cm, grays mouth gags for dogs ss-304, 16cm, haver sac bag 18"ht. x18"length x6" width, hog catcher standard, instrument tray s.s. -304with lid 250mmx300mm, instrument tray s.s. -304with lid 350mmx300mm, intra medullary bone pins assorted size, long forcep (ss-304) 45 cm, metal catheter for bitch standard, mouth gag for cattle standard, ointment slab porcelain 20 cmx20 cm, operation table for small animals-1- operation table for small animals suitable for general surgery ss hydraulic o.t. table, five section ss top and heavy base and column. all sections covered with mattresses. height adjustable range ( in mm ): 75mm to 1000mm, trendelenburg: 30 degree, max. load 120 kg , table lenght 1830mm, table width 497mm, height adjustable, back rest up 80 degree/dowm 25 degree, lateral tilt 20/20 degree , head rest up 20 degree/down 60 degree, trendelenburg reverse 25 degree, orthopedic saw, (ss-304) 30 cm with adjustable blades, otoscope and opthalmoscope set otoscope and opthalmoscope set of good quality and for veterinary use. it should be batteries operated and easy to handle, otoscope head with 4x magnification, 3 specula of size 80mmx6mm, 58mmx5mm, 80mmx4mm with one spare bulb, one opthalmoscope head., plaster cutting saw s.s. 4cm wide 20 cm., post mortem kit for poultry-scissors mayos ss, 20cm-2, scissors mayos ss, 15cm-2, long forceps ss 20cm-2, magnifying glass, 6cm dia-2, bone cutter ss, 20cm-1, b.p. handle ss, no
Tender For supply of work station for office - no of work station 6 members ceatable supply and fixing , supply and fixing of 25mm thick prelaminated board table top , supply and fixing of 25mm thick prelaminated board vertical support 18 nos , metal keyboard tray , metal cpu trolly , mobile drayer unit , supply of chair , supply and fixing of false ceilling gyptech , supply and fixing of 2 by 2 led light fitting , supply and fixing of ac voltas 1 and 5 ton
Tender For sitc of various essential equipments for the use of various municipal maternity homes - 200/250 amp. 415v tpn switchfuse unit with crca sheet steel powder coated enclosure with hrc fuses & switch links and padlockable arrangement., cable end boxes 200/250 amp. tpn switch fuse, 200 amp. 415v fp on load changeover switch with crca sheet steel powder coated enclosure., supply, installation, testing and commissioning of 50kva dg set comprising of cpcb iv mech, built in amf panel, 1500 rpm, 4 stroke, 3 cylinder inline type, water cooled with radiator diesel, 1st category al armoured cables frls outer sheathed- 3.5c x 95 sq.mm, cable end termination for aluminium cables 3.5c x 95 sq.mm, 3 noss. single core cu pvc insulated flexible cable of 50 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 25 sq.mm for 100/125 amp. tpnss switch., cement concrete foundation using m-20 cement concrete mix with j shaped foundation bolts where required, supply & laying of double wall corrugated ( dwc) pipe 125 mm od / 109 mm i.d., concrate excavating the trenches and refilling the same after the cable is laid in approved manner (size of trench: 750 mm deep, 600 mm wide) in concrete/ masonary / asphalt. 1 cu. mtr. = 2.2 rmt., soil excavating the trenches and refilling,reinstatement of the same after the cable is laid in approved manner (750 mm deep, 600 mm wide),in all types of soils 1 cu. mtr. = 2.2 rmt., providing, detailing, composite fabricating members like trusses, ngirders,girders, bracings, supports, purlins, runners, and similar structural steel members fabricated using m.s. hollow tubular steel, bare galvalume/zincalume sheets for roofing, earthing station with 600 mm x 600 mm x 6 mm galvanised iron plate, 25 x 3mm gi, bare g. i. conductor size 10 swg., removal of switchgears/ dbs upto 200 amp., removal of switchgears/ dbs above 200 amp to 400 amp., removal of busbar chamber above 100 amp tpn to 800 amp tpn., removal of cable above 3-1/2 core x 35 sq. mm. to 3-1/2 core x 70 sq. mm, removal of cable from 1.5 sq.mm to 3-1/2 core x 35 sq.mm., refixing of 2 core/ 3 core/ 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable 1.5 sq.mm. to 16 sq.mm. size on wall / ceiling etc., refixing of 2 core / 3 core / 3-1/2 core / 4 core/ 6 core copper / aluminium conductor armoured / unarmoured cable above 16 sq.mm. to 150 sq.mm. size on wall / ceiling etc., 415v main distribution panel 1 short circuit reating 50ka for 1 sec. 400a (thermal magnetic overload, short circuit release) mccb with rotary operating mechanism as incomer with digital ammeter,, 200a 4p mccb, 100a tpn mccb, 3 noss. single core cu pvc insulated flexible cable of 95 sq.mm. for phases & 1 single core cu pvc insulated flexible cable for neutral of 50 sq.mm for 200 amp tpnss switch., g.i. cable tray with all other accessories 150 x 25mm (w x h) - (16 swg - 1.6mm) without cover, cable end termination for aluminium cables 3.5c x 50 sq.mm, cable end termination for aluminium cables 3.5c x 120 sq.mm, cable end termination for aluminium cables 3.5c x 70 sq.mm, cable end termination for aluminium cables 3.5c x 50 sq.mm, 20w led flood light luminaire ip65, 1st category al armoured cables frls outer sheathed- 2c x 6.0 sq.mm, gun metal gate valves (screwed):-50 mm dia., gun metal non - return valve: (screwed):-50 mm dia., gun metal gate valves (screwed):-15 mm dia., gun metal foot valve 50 mm dia., automatic pump control panel, hose oil cooler to water pump, worm drive hose, fuel supply pipe, injector overflow pipe (return pipe), hose for oil cooler inlet, hose clip thermostat, vent hose (epdm) for gens, ax-45-cogged belt, hose water manifold to ther, dse 6120/ 4520 controller, battery exide 12v 110ah, oil filter 4 cyl -, fuel filter 4 cyl -, air filter element outer 4 cly m&m, centrifugal oil filter 4c, radiator aluminium, radiator exhaust fan, radiator core, charging alternator, alternator winding main, alternator ar
Tender For corrigendum : tender document for supply of laboratory instruments and equipments as per boq - name of the instruments, ft-ir microscope with chemical imaging system for analysis of microplastic samples along with use as normal ftir. it should be a non-destructive technique and analyzed upto 5 microns samples, toc analyzer for liquid samples, solids foods, plant extract and other samples with ndir detector with halide scrubber and moisture traps, tn analyzing unit based on thermal conductivity detection (tcd), auto sampling unit. the instrument should simultaneously and/or stand-alone measure toc and tn in seawater samples. pc controlled with software, robotic bod analyser (sample capacity bod: 108 bod bottles (6 rack for holding 300ml wheaton bod bottles, addition of atu and dilution water automatically into the wheaton bottles, for bod automation, tray for calibration buffers, qc s and probe parking position, moving mechanism xyz with safety protection), computer controlled true double beam uv-visible spectrophotometer for liquid sample analysis in reflectance /transmission and absorbance mode. the system should have the capability of analyzing colour, transition metal ions, highly conjugated organic compounds, and other samples precisely and accurately. stand-alone operation as well as complete control through pc with pc software supplied as standard., automatic weather monitoring station, inductive coupled plasma mass spectrometry (icp-ms), details of buy-back instrument, icp-ms (make: perkin model:nexion 300x) details as per annexture, total organic carbon (toc) analyzer,(instrument set consiting of toc instrument,auto sampler/ diluter,data work station) other details as per annexture, fourier transform infrared spectroscopy (ftir) (make:agilent technologies, model:cary 660 ftir, serial number:my14200004) as per annexture, uv-vis spectrophotometer (make:perkinelmer,model:lambda 45) details as per annexture