Tender For supply, installation, testing and commissioning of chlorine dosing pump and allied works at various booster pumping station in ambedkar nagar constituency ac-48. - dosing pump set of capacity 9.5 lph 07 kg/cm2 pressure with pp head along with pvc fitting - ant syphon valve, foot valve & ldpe tubing. make : milton roy/clomax/djb approved., installation & commissioning of dosing pumps set with proper wall supporting arrangement to hold the pump sets. the work includes providing of all pipes and special to supply the hypo chlorite solution properly to main delivery lines by making holes with utmost care and make the systems leak proof and testing on full load durng running of pump., fixing of ms socket of required sized by drilling / threading / welding/ and making it leak proof fixing of suitable nozzle for injecting chlorine solution at the time of operation of bps/optional., providing of 500 ltrs pvc dosing media container.
Tender For strengthening of external lighting equipment installed at meethapur store and shamshan ghat molarband extension bps under badarpur constituency ac-53. - supplying and embedding 32 mm dia g.i. pipe (medium class) in pole collar/ foundation (during casting) for cable entry including bending the pipe to the required shape complete as required., supplying and fixing dp sheet steel enclosure on surface/ recess along with 25/32 a 240 v "c" curve dp mcb complete with connections, testing and commissioning etc. as required., supply of 45 w led new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminum housing with high efficient led as lighting source and pc cover having top opening separate driver compartment with ip66 protection and impact resistance of ik07., supply of pole mounted cable junction box of size 305x250x128mm having ip 65 protection with complete accessories as per site requirement. make:-sintex/hesel., fixing of control junction box with the help of nut, bolts, washers, fasteners etc. as per site requirement., wiring for circuit/sub main wiring along with earth wire with the following sizes of frls pvc insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 x 4 sq. mm + 1 x 4 sq. mm earth wire., installation, testing and commissioning of pre wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm frls pvc insulated, copper conductor, single core cable and earthing etc. as required.
Tender For supply, installation, testing and commissioning of chlorine dosing pump with all allied accessories of various booster pumping station in cr park ward under greater kailash constituency ac_50. - dosing pump of capacity 9.5 lph, 7 kg pressure/cm2, pp head along with pvc fitting syphone valve, foot valve & ldpe tubing. make: milton roy/clomexdjb approved, installation, testing & commissioning of dosing pump sets with proper wall supporting arrangement to hold the pump set, the work includes providing all pipes and special to supply sodium hypo chlorite solution properly to main delivery line by making holes with utmost care and make the systems leak proof and testing on full load during running of pump as per site requirement & direction of engineer in charge., fixing of ms socket of required size by drilling / threading / welding and making it leak proof fixing suitable nozzle for injecting chlorine solution at the time of operation of bps as per site requirement & direction of engineer in charge., providing of 500 ltr pvc dosing media container.(chlorine resistant)
Tender For supply, installation, testing and commissioning of radar type pressure transducer of 2 nos. pump sets at jaitpur village bps under badarpur constituency ac-53. - supply of digital pressure transducer, range 0-16 kg/cm2, connection 1 4 bsp (m), body ip 65, accuracy +/- 0.5%, output 4-20 ma, input 24v dc, operating temperature -20deg. to 80 deg. c, deviation 0.3%, protection cover for digital pressure transducer. supply of 7 segment indicator with 4-20 ma input, 4 digit indicator, character size 4 inch with provision of decimal, provision for wall mounting / hanging, ms body with powder coating. supply of 2 core x 1.5 sq mm cable approx 25 mtr. installation, testing and commissioning charges including all the electrical work to be done installation of switch, socket in the gang box (waterproof pvc), pvc pipe for all the wiring and the interconnections between the transducer and indicator. make: skope/ vega/seimens/eip/djb approved
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim
Tender For bid to ras supply of providing amf panels for various capacity engine alternator set in te bldgs under kollam ba d d - sitc of free standing, outdoor cubicle type microprocessor based amf panel 30 kva , sitc of free standing, outdoor cubicle type microprocessor based amf panel for 20 kva , supplying, laying and fixing of al power cable in pipe , supplying, laying and fixing of al power cable on surface of wall , supplying, laying and fixing of al power cable in masonry open duct , supplying and making end termination with brass compression gland , supplying, laying and fixing of 8 c 1.5sq.mm pvc flexible cable , supplying and laying of 2 x 6 sq mm pvc insulated , supplying, laying of 16 sqmm size frls pvc insulated copper conductor , supplying and laying of industrial telephone cables , supplying and laying of dwc hdpe pipe , supply and fixing the steel wire reinforced flexible upvc conduit , sf 40 mm dia gi pipe , supplying and fixing of medium class pvc conduit , supplying and fixing of spn db , replacement of 12v, stop solenoid , llop sensor , hct hwt sensor , sensor float , start stop relay , 12 v oen pla relay , dismantling of the existing dg control panel , rerouting of the existing cable
Tender For bid to ras corrigendum : supply of wifi solution with wifi enabled tablets d d - wi-fi access point controller -on premise , network switch poe 8 port , 10g sm transceiver , 1g sm transceiver , wi-fi access point - indoor , wi-fi access point - outdoor with long arm pole mounting bracket , on-prem secure access for user license for 50 user for 5 year , mdm software with 50 device licenses -on premise- with installation and training , tablet device , 12 core singlemode armoured fiber cable make-commscope- amp,molex, systimax,panduit , fully loaded liu -pig tails, fiber coupler, splicing tray, adapter plate and other required accessories with lc type sm-12 port - make- commscope- amp,molex,systimax,panduit , fiber optic patch cord -lc-lc-sm duplex- 1 meter , cat 6 utp cable box -305 m each , cat 6 utp armoured cable box -305 m each , cat6 utp patch cord - length -1 meter , cat6 utp patch cord - length -3 meter , 9u indoor network rack with pdu with accessories , dual face plate with i by o keystone with iron type back box -make- commscope- amp,molex,dlink,systimax,panduit , shielded rj 45 jacks with cover - make-commscope- amp ,molex,dlink,systimax,panduit , supply of 1 by 2 inch hdpe pipe , 1-inch conduit pipe , 1 by 2 inch inch gi pipe , 1 inch pvc flexible pipe with accessories , supply of 6 meters round gi pole with basement unit and fixtures for outdoor wi-fi access point , manual digging of soft or hard soil depth 3 feet and refilling with same with hdpe pipe for utp armoured cable , concrete cutting and refilling with rcc for gi pipe , laying of cat6 cable or cat6 armoured cable in supplied conduit, hdpe, casing and capping indoor and outdoor etc with required accessories , laying of ofc in supplied hdpe on wall though clamping etc , installation, termination, fixing of wi-fi access point with long arm pole or wall mounting bracket, dressing, labeling etc , termination of i by o nodes at user side with back box, face plate with labeling and testing , installation of gi pole with concrete basement for outdoor wi-fi access point , configuration of wi-fi access point, wi-fi access point controllers and setting up management server or software for entire access points and integration with the existing network , connecting utp patch cords, fixing, splicing and labeling , installation and configuration of switches, etc , integration of entire system, testing -fluke-, documentation and training etc
Tender For supply of supply of stand mounted fabricated prefabricated sub main distribution board smdb , itc and labelling of floor mounted pre fabricated , supply of surface recess , itc of pre fabricated 3 phase 415v 6 way tp surface , supply of pre fabricated 240 v rated 6 way , itc of pre fabricated 240 v rate 6 way sp , supply of 4 pole 160a manual changeover switch disconnector , itc of 4 pole 160a manual changeover switch disconnector with terminal shrouds , laying of pvc insulated and pvc sheathed xlpe , laying of pvc insulated and pvc sheathed xlpe power cable , laying of one number pvc insulated and pvc sheathed xlpe , supply of 4c x 10 sq mm stranded copper conductor , laying of 4c x 10 sq mm stranded copper conductor , supply of indoor end termination , making indoor end termination , supplying 300 mm width x 50 mm depth x 1 6 mm , installing 300 mm width x 50 mm depth x 1 6 mm , supplying 100 mm width x 50 mm depth x 1 6 mm , installing 100 mm width x 50 mm depth x 1 6 mm , supplying 25 mm x 6 mm g i strip , laying 25 mm x 6 mm g i strip , supply of 6 swg dia g i wire , fixing 6 swg dia g i wire , supply of maintenance free earth kit , itc of maintenance free earth kit , supply of frls pvc insulated stranded copper conductor , drawing of frls pvc insulated stranded copper conductor , supply of 20mm size of isi marked hgms ms black painted conduit , installation of 20mm size of isi marked hgms ms black painted conduit , supply of 25mm size of isi marked hgms ms black painted conduit , installation of 25mm size of isi marked hgms ms black painted conduit , supplying 1 or 2 module 75mmx75mm size gi box with modular base , fixing 1 or 2 module 75mmx75mm size gi box , supplying 4 module 125mmx75mm size gi box , fixing 4 module 125mmx75mm size gi box , supplying 6 module ) /bid number: gem/2025/b/6962998 * /dated: 09-12-2025 & & / bid document1 / 49 & & ' ' /item category200mmx75mm size gi box , fixing 6 module 200mmx75mm size gi box , supplying 8 module 125mmx125mm size gi box , fixing 8 module 125mmx125mm size gi box , supplying 5 6 amps modular switch , fixing 5 6 amps modular switch , supplying 3 pin 5 6 amp modular socket outlet , fixing 3 pin 5 6 amp modular socket outlet , supplying 15 16 a modular switch , fixing 15 16 a modular switch , supplying 6 pin 15 16 a modular socket , fixing 6 pin 15 16 a modular socket outlet , supplying 3 pin 5 a ceiling rose , fixing 3 pin 5 a ceiling rose , supply of 1 phase 230v 35w or better batten type , installation of 1 phase 230v 35w or better batten , itc of ceiling fan , supply of 300 mm sweep heavy duty size exhaust fan , itc of 300 mm sweep , supplying 20 a 240 v spn industrial type socket outlet , fixing 20 a 240 v spn industrial type socket outlet , supply of 2cx1 5mm2 copper extruded pvc inner sheath armoured , laying of 2cx1 5mm2 copper extruded pvc inner sheath armoured , supply of addressable photo thermal multi sensor smoke detector ivory , itc of addressable photo thermal multi sensor smoke detector ivory , supply of addressable flex manual call point , itc of addressable flex manual call point , supply of addressable intelligent wall mounted sounder strobe , itc of addressable intelligent wall mounted sounder strobe , supply of junction box with elmex type terminal block , installation of junction box at ceiling wall surface recess , integration of the fire detectors mcp sounders , dismantling of one 01 no existing floor mounted electrical panels , dismantling of cables of size upto 150 sq mm , dismantling of incoming cables of size 16 35 sq mm , dismantling and removing of existing switchboard industrial sockets , dismantling of existing g i strip upto size of 25mm x 6mm , dismantling of existing conduits sizes 20mm 25mm 32 mm , dismantling of existing fire detector mcp sounder fire panel