Get complete information related to latest Pc Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pc Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pc Tenders.
Tender For supplying diff type of material - supplying and providing material, garbage tipper mounted on four wheel bsvi vi ( diesel). container make in 16 gauge m s sheet & c channel frame 75x40, two side foot rest in 16 gauge. container of garbage capacity 1.5 cum .battery operated d.c power pack 12v, 6 lpm motor r.p.m 1400 with 08 ltr oil tank with indicator level solid valve & up & down switch hydraulic cylinder 450 stroke x 40 bore, anti corrosive paint, two coat of synthetic enamel paint., wheel dustbin 120 ltr nilkamal, computer all in one 23.8 screen / 8gb ram /512ssd, dsc setup installation with browser setting, old pc hdd deta recover with shifting new pc, egram soft mdf_deta recovery_ e gram app_installation
Tender For provision of safety fencing along the track in mmr-pc section under jurisdiction of aden csn of bsl division. project id: 01.01.16.23.1.50.002.
Tender For provision of safety fencing along the track in mmr-pc section under jurisdiction of aden csn of bsl division. project id: 01.01.16.23.1.50.002.
Tender For provision of safety fencing along the track in pc-dsk section under jurisdiction of aden (l) bsl of bsl division. project id: 01.01.16.23.1.50.002.
Tender For supply installation testing and commissioning of png line in kitchen area and various lab in cn tower and dr rp centre and faculty and staff cafeteria in pc and teaching block at aiims new delhi
Tender For 1 b replacement and pitc of window and split new air conditioners and 15 50 lph ros in pc and tc block new pvt ward outer area and at various locations in aiims new delhi sh ro works only approved in eac 100 at special repair no13b 2 replacemnet of window and split air conditioners and 15 50 lph ros in pc and tc block new pvt ward outer area and at various locations in aiims new delhi sh ro work only approved in eac 100 at special repair no 09
Tender For pc-1423 manufacture, testing, supply and commissioning of leaky insulator detectors as per tender technical specification and to provide training to the staff of the concerned divisions in gescom to use them
Tender For pc-1407 manufacture, testing, supply and commissioning of distribution transformer test benches as per tender technical specification and to provide training to the staff of concerned divisions in gescom to use the test benches
Tender For corrigendum : 21/2024-25 purchase of laqshya instrument - purchase of instrument ( laqshya), radiant warmer- technical specification of radiant warmer with baby bassinet a radiant warmer is used to keep the patient s core temperature stable at 37 o c. it should be microprocessor controlled radiant warmer with manual and servo options. it should have facility to display both skin and air (ambient) temperature separately.. it should have audiovisual alarm facility for overheating beyond set temperature range. it should have alarm facility for patient temperature less than or greater than the required temperature i.e. above or below the set range. it should rotate and swivel in different direction, so as to allow taking x-ray. the light should be dazzle free. it should have alarm for power failure. it should have alarm for heater failure and auto cut off for high temp. it should have alarm for probe failure. it should have time out alarm in manual mode. it should have facility to auto reset the system in case of hang up caused by power fluctuation. it should have manual setting for high and low alarm setting. in servo mode, the heater output should be controlled to maintain the baby at the required set temperature. in manual mode, the heater output should be directly controlled by a setting on the front panel should have a facility to lock the keyboard to avoid unwanted user. the desired temperature range from 25 to 40 degree c. the resolution should be 0.1 degree c halogen based observation light should be provided for observing the baby. it should be mounted on a pole with sturdy base with lockable castors power supply: power input to be 220-240 vac, 50hz fitted with indian plug. certificate of calibration and inspection from the factory. warranty: comprehensive warranty for 5 years after warranty documentation: user, technical, maintenance manuals to be supplied ce, iso certified , fetal doppler - technical specification of fetal doppler should be compact, table type and light weight. large lcd display for display of fetal heart rate. back light for better visibility display signal quality, low battery, etc., high sensitivity doppler probe of frequency 2.0 mhz ultra sound intensity 10mw/cm2. built-in speaker with output not less than 1.0w should work on rechargeable batteries with minimum battery time of 300minutes. battery charger and spare set of batteries aa type to be supplied. volume control facility and audio output for ear phone should be available. heart rate range should be from 50 to 240 b pm with accuracy of + /-2% should be water proof body. should have facility for fhr data transfer to pc. doppler probe should be light weight with holder facility when not in use. should be supplied with carrying case. machine should be iso mark, baby digital thermometer - technical specification of baby digital thermometer range 0.1 to 1000 degree centigrade measurement mode- min, max, average, differential, dual temperaturereading measurement unit- degree centigrade, degree fahrenheit,kelvin temperature probe with connecting cable relative humidity10 to 90% rh non-condensing ip rating- ip 40 g) probe response time 2-3 seconds it should be who & unicef standards, fetoscope - technical specification of infant fetoscope should be 135 75mm weight should be up to 350gm should be 40cm h20 presser limiting valve inspiratory resistance should be 5cmh2o (at 50l/min), delivery trolley/patient stretcher trolley- technical specification of patient stretcher trolley overall size: 1905mm l x 710mm w x 660mm to 910 mm h. stretcher dimension 1830 mm l x 555 mm w. two section top. height adjusted by foot operated maintenance free hydraulic pump. height adjustment shall be obtained by hydraulically operated mono block type linear actuator pump foot operated actuation having stroke of 140 +/- 5 mm, push force 10 kn at 270 bars, number of complete pump stroke 22 to 24 for full stroke length x-ray permeable removable stretcher, backrest raised on