Web Analytics Made Easy - StatCounter

Pen Rail Road Tenders

Get complete information related to latest Pen Rail Road Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pen Rail Road Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pen Rail Road Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :38556433 Due date: 03 Jan, 202503 Jan, 2025 NA
Tender For supply of pbs ph 7 4 500ml , tmb solution ready to use , carbonate bicarbonate buffer for elisa ph 9 6 , 0 5 10ul microtips with filter with rack box 960 tips by case , sodium chloride 500gm , spectra por 131090t biotech grade dialysis tubing trial kit 0 5 1 0 kdalton 16 mm , borosilicate glass petridishes 90mm x 17mm 10 pieces per pack , tmb substrate solution make himedia

CTN :38504131 Due date: 30 Dec, 202430 Dec, 2024 NA
Tender For supply of accommodation ladder with winch ngopv ncm nc - 3037__service assistance_complete installation__mc-ser10359 , 22_yard-3038__port alu.accomm ladder is-2.5m_nes-127__mc- 372649130001 , 23_yard-3038__stbd alu.accomm ladder is-2.5m_nes-127__mc-372649130002 , 24_yard- 3038__port winch complete _is-8994 or iso 7364__mc- 372649130003 , 25_yard-3038__stbd winch complete_is- 8994 or iso 7364__mc-372649130004 , 26_yard-3038__portable hand operated control__mc- 372649130005 , 27_yard-3038__m.s stowage box of suitable size_accommo__mc-372649130006 , 28_yard- 3038__obs_2 yrs-mechanicalandelectrical- _accomm.__mc-372649138001 , 29_yard- 3038__inspectionandtest certificates_accommodatn__mc-372649139001 , 30_yard-3038__load test certificates of accommodation__mc-372649139002 , 31_yard- 3038__material test and guarantee certificate.__mc- 372649139003 , 32_yard-3038__binding drawings__mc- 372649139004 , 33_yard-3038__installation procedure- manual-specfcatn__mc-372649139005 , 34_yard-3038__instrctn,opertnandmaintnce manuals,cplandpil__mc-372649139006 , 35_yard- 3038__preservation procedure and maintenance__mc-372649139007 , 36_yard-3038__graq - for harbour and sea trial-.__mc-372649139008 , 37_yard-3038__as-made equipmentandsystem drawings__mc-372649139009 , 38_yard- 3038__instructn,opertnandmaintnce manuls,cplandpil__mc-372649139010 , 39_yard- 3038__factory acceptance trialandinspectn cert.__mc-372649139011 , 40_yard-3038__design data booklet,loadandshock calculatn__mc-372649139012 , 41_yard-3038__material test cert,motor test cert.andothr__mc-372649139013 , 42_yard- 3038__service assistance_complete installation__mc-ser10359 , 43_yard-3039__port alu.accomm ladder is-2.5m_nes-127__mc- 372649130001 , 44_yard-3039__stbd alu.accomm ladder is-2.5m_nes-127__mc-372649130002 , 45_yard- 3039__port winch complete _is-8994 or iso 7364__mc- 372649130003 , 46_yard-3039__stbd winch complete_is- 8994 or iso 7364__mc-372649130004 , 47_yard-3039__portable hand operated control__mc- 372649130005 , 48_yard-3039__m.s stowage box of suitable size_accommo__mc-372649130006 , 49_yard- 3039__obs_2 yrs-mechanicalandelectrical- _accomm.__mc-372649138001 , 50_yard- 3039__inspectionandtest certificates_accommodatn__mc-372649139001 , 51_yard-3039__load test certificates of accommodation__mc-372649139002 , 52_yard- 3039__material test and guarantee certificate.__mc- 372649139003 , 53_yard-3039__binding drawings__mc- 372649139004 , 54_yard-3039__installation procedure- manual-specfcatn__mc-372649139005 , 55_yard-3039__instrctn,opertnandmaintnce manuals,cplandpil__mc-372649139006 , 56_yard- 3039__preservation procedure and maintenance__mc-372649139007 , 57_yard-3039__graq - for harbour and sea trial-.__mc-372649139008 , 58_yard-3039__as-made equipmentandsystem drawings__mc-372649139009 , 59_yard- 3039__instructn,opertnandmaintnce bid details/ 2 / 71 manuls,cplandpil__mc-372649139010 , 60_yard- 3039__factory acceptance trialandinspectn cert.__mc-372649139011 , 61_yard-3039__design data booklet,loadandshock calculatn__mc-372649139012 , 62_yard-3039__material test cert,motor test cert.andothr__mc-372649139013 , 63_yard- 3039__service assistance_complete installation__mc-ser10359 , 64_yard-3040__port alu.accomm ladder is-2.5m_nes-127__mc- 372649130001 , 65_yard-3040__stbd alu.accomm ladder is-2.5m_nes-127__mc-372649130002 , 66_yard- 3040__port winch complete _is-8994 or iso 7364__mc- 372649130003 , 67_yard-3040__stbd winch complete_is- 8994 or iso 7364__mc-372649130004 , 68_yard-3040__portable hand operated control__mc- 372649130005 , 69_yard-3040__m.s stowage box of suitable size_accommo__mc-372649130006 , 70_yard- 3040__obs_2 yrs-mechanicalandelectrical- _accomm.__mc-372649138001 , 71_yard- 3040__inspectionandtest certificates_accommodatn__mc-372649139001 , 72_yard-3040__load test certificates of accommodation__mc-372649139002 , 73_yard- 3040__material test and guarantee certificate.__mc- 372649139003 , 74_yard-3040__binding drawings__mc- 372649139004 , 75_yard-3040__

CTN :38343972 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For supply, installation, testing and commissioning of internal wiring of pump house in pvc casing capping on surface of wall and supply of 50w to 100w led flood light at required place. all wiring work as per is 732. making wiring point for exhaust fan, light, plug, led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated of multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for light and 15a/16a for exhaust fan, power plug) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (0.5a to 5a and 6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). power wiring should be done by 2.5 sqmm multi strand copper wire. dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractor at saryu pump canal, stage-ii nanpara, bahraich under modernization project of electriacal & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich

CTN :38343973 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For supply, installation, testing and commissioning of internal wiring of pump house in pvc casing capping on surface of wall and supply of 50w to 100w led flood light at required place. all wiring work as per is 732. making wiring point for exhaust fan, light, plug, led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated of multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for light and 15a/16a for exhaust fan, power plug) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (0.5a to 5a and 6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). power wiring should be done by 2.5 sqmm multi strand copper wire. dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractor at saryu pump canal, stage-iii nanpara, bahraich under modernization project of electriacal & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich.

CTN :38343974 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For supply, installation, testing and commissioning of external wiring around outer wall of pump house in pvc casing capping and wiring of long steel tubular pole with aluminum conductor pvc insulated armoured sheathed cable 1100v for 50w to 100w led flood light at required place. all wiring work should be as per is 732 and is 1944. making wiring point for led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for led flood light) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractoratat saryu pump canal, stage-ii nanpara, bahraich under modernization project of electrical & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich.

CTN :38343975 Due date: 26 Dec, 202426 Dec, 2024 NA
Tender For supply, installation, testing and commissioning of external wiring around outer wall of pump house in pvc casing capping and wiring of long steel tubular pole with aluminum conductor pvc insulated armoured sheathed cable 1100v for 50w to 100w led flood light at required place. all wiring work should be as per is 732 and is 1944. making wiring point for led flood light with 1.5 sqmm and 2.5 sqmm frlsh pvc insulated multi strand copper conductor cable and 14 swg copper earth continuity wire providing piano type switch (6a for led flood light) with 32a / 240v i.c. cutout on meter or polished mdfeg flash teak wood board and separate mcb (6a to 32a) for each section with din rail mounting arrangement. for input supply of line provide aluminium conductor pvc insulated armoured sheathed cable 1100v (underground). dismantling of all old accessories wiring and component is under scope of contractor. all necessary t&p such as flat batten clip, pvc tape etc. and all necessary accessories such as coupler, l-joint, t-joint, internal, external, plastic grip, concrete nail of required size, mcb box etc. should be under scope of contractor and trial & testing should be done in last by contractoratat saryu pump canal, stage-iii nanpara, bahraich under modernization project of electrical & mechanical work of saryu pump canal, stage ii & iii, nanpara, bahraich
 Loading, Please wait...

Connect us via What's Up