Web Analytics Made Easy - StatCounter

Photodiode Tenders

Get complete information related to latest Photodiode Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photodiode Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photodiode Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :41039241 Due date: 21 Jul, 202521 Jul, 2025 16.10 Lacs
Tender For procurement of spares for compex pro 205 excimer laser - polishing powder, for optics260146, halogen filter set 261068, 952487 substrate 40x40x1.5 fused silica chtg-lb-t2, 1195817 terminal block set for thyratron, lpx / compex, spare part, 90517301 resistor, 470 ohm, 55w, spare part set with adapter rings, 1133749 fuse set, 24vdc, spare part, 1149238 mesh filter spare part set, 1173207 photodiode spare part, 1180712 laser valve repair kit, 0.8-2.8mm, 24vdc, spare part, 1428469 laser hv-trigger, spare part, 1128329 laser varistor, spare part, laser vacuum pump 1099418

CTN :40977997 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For supply of hamamatsu si photodiode s1336-bq , hamamatsu si quadrant photodiode s10359

State Government

CTN :40841890 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply and installation of laboratory equipment experimental setup for fyimp ug practical classes at the department of physics, gauhati university - laboratory equipments/experiment set ups, experiment name: to verify the law of malus for plane polarised lighttechnical specifcations:i. light source: - led: 532 nm or 635 nm ( 2 nm stability), 1 5 mw adjustable output. - unpolarized (extinction ratio >500:1). - collimated beam (divergence 0.5 mrad); qty-1ii. polarizers- glan-thompson or polymer film. - extinction ratio 10 :1 @ operating wavelength.- mounted in 50 mm rotation holders.; qty-2iii. rotation stage- motorized analyzer rotation (0.05 resolution). - accuracy: 0.1 . - range: 0 360 (continuous).; qty-1iv. photodetector- silicon photodiode (400 1100 nm). - linearity: r 0.999 (0.1 w 5 mw).- digital readout: 0.1 w resolution.; qty-1v. optical bench-- anodized rail ( 60 cm) with kinematic mounts. - vibration-damping feet.; qty-1, experiment name: to determine thespecific rotation of sugar solution using polarimetertechnical requirementsa.core instrumenti. light source- - sodium d-line (589.3 nm) or tunable led ( 2 nm stability). - output stability: 0.2% drift/hour.ii. polarizer/analyzer- glan-thompson prisms or high-grade polymer film. - extinction ratio 10,000:1 at 589 nm.iii. rotation stage- motorized with 0.001 resolution.- accuracy: 0.005 .- range: -90 to +90 .iv. sample cell-- borosilicate glass tubes with precision ground ends. - path lengths: 0.5 dm, 1.0 dm, 2.0 dm ( 0.01 dm tolerance). - temperature-controlled jacket (5 50 c 0.1 c).v. detector- photomultiplier tube (pmt) or low-noise photodiode. - linearity: r 0.999 over 0.1 w 5 mw rangevi. enclosure- light-tight with vibration damping. - internal black anodized surfaces.b.measurement specificationsi. specific rotation: range: -180 to +180 resolution: 0.001 accuracy: 0.01 ii. concentration-range: 0.01 0.5 g/ml (sucrose in water) detection limit: 0.001 g/mliii. temperature control-stability: 0.1 c at 20 c (standard condition), experiment name: to determine the wavelength and velocity of ultrasonic waves in a liquid (kerosene oil, xylene, etc.) by studying the diffraction through ultrasonic gratinga.core componentsi. ultrasonic generator- - frequency range: 1 10 mhz ( 0.1% stability). - adjustable output: 0 50 w. - digital display (resolution: 0.01 mhz).ii. transducer- piezoelectric (pzt) crystal, resonant at 2 5 mhz. - liquid-coupled design for efficient energy transferiii. liquid cell- optical glass (low thermal expansion). - dimensions: 100 50 50 mm (l w h). - sealed with quartz windows.iv. light source- he-ne laser (632.8 nm, 2 mw) or sodium lamp (589.3 nm). - beam collimation: 0.5 mrad divergence.v. optical system- adjustable slit (10 500 m). - collimating lens (f = 150 mm, 50 mm). - precision rotation stage for detector (0.01 resolution).vi. detection system- photodiode/pmt detector with linear response (400 800 nm). - traveling microscope (0.01 mm resolution) or ccd camera ( 5 mp).b.measurement specificationsi.wavelength ( )range: 0.1 2 mm, resolution: 0.001 mm, accuracy: 1%ii. velocity (v)range: 800 2000 m/s (liquids) resolution: 1 m/s accuracy: 2%iii. diffraction angles- measurement range: 30 resolution: 0.01 , experiment name: to verify the stefans law of radiation and to determine stefan s constanta.core componentsi.black body radiator- cavity-type design (emissivity 0.99). - material: nickel-plated copper.- operating range: 50 c 600 c. - aperture diameter: 10 mm 0.1 mm.ii. heating system- pid-controlled furnace (0 600 c). - stability: 0.5 c at 300 c. - power: 500 w (ac 230v).iii. temperature sensor- type k thermocouple or pt100 rtd. - accuracy: 0.5 c at 500 c (nist-traceable).iv. radiation detector- thermopile sensor (spectral range: 0.3 20 m). - responsivity: 10 v/w.- active area: 10 10 mm .v optical path. - water-cooled collimating tube with baffles.- adjustable aperture to define solid angleb.measurement specificationsi. temperature range100 c 500 c (reso

Central Government/Public Sector

CTN :40793195 Due date: 12 Jul, 202512 Jul, 2025 NA
Tender For supply of sensing and instrumentation kits - level measurement trainer, transducers trainer, hall effect trainer, wheat stone bridge, decade resistance box, load cell trainer, torque measurement trainer, schering bridge, decade capacitance box, thermocouple module, thermistor module, ldr/, photodiode and photo transistor trainer
 Loading, Please wait...

Connect us via What's Up