Get complete information related to latest Photometer Device Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photometer Device Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photometer Device Tenders.
Tender For supply of machine, equipment and others - list of machine and equipments, laproscopic hd camera brand - karl storz/conmed/olympustechnical specificationresolution: 1920x1200 pixes / 1900x1000 pixescable length: 300 cm, ultrasonic harmonic scalpelbrand - johnsontechnical specificationdimensions: (hxwxd) 5.3" 14.5"x15.2" voltage: 100-240 vac frequency: 50/60 hz rated current: 3 amp , ultrasonic harmonic scalpelbrand - valley labtechnical specification macrobipolar/bipolar: 473 khz sinusoid, 100% duty cycle. seal: 473 khz sinusoid pulsed , hand instruments for laproscopy brand- karl storz/ olympustechnical specification i) veress needle: it should be with spring action blunt style -12 cm: 1 no 10 cm: 1 no 8 cm: 1 no ii) trocar and cannula: 10 mm: 2 nos 7 mm: 1 no. 5 mm 6 nos it should consists of trocar, cannula with insufflation and multifunctional valve and must have pyramidal tip. iii) reducer/reduction sleeve 5 mm. 1 no iv) telescopes: 10 mm- 0 - 1 nos -30 - 1 nos 5 mm-30 1 nos rigid rod lens system provides good resolution and the better dept perception. it should have uniform image brightness and autoclavable. the 300 forward oblique angle and permits for greater latitude for viewing underlying areas under difficult anatomical conditions. v) suction cannula: 10 mm - 1 no 5 mm -1 nos vi) laparoscopic scissors: curved (monopolar metzenbaum dissector 5mm diameter): 1 nosstraight (bipolar): 1 nosperitoneal scissor: 1 nosvii) unipolar forceps (hook & spatula): 2 nos viii) bipolar forceps : 2 nos ix) atraumatic forceps: maryland dissector forceps: : 2 nos. fenestrated forceps: : 2 nos. x) needle holder (flat jaw) with handle : 2nos xi) monopolar cable (reusable):1 nos. xii) bipolar cable (reusable): 1 nosxiii) allis (double row of teeth) grasper: 1 nos xiv) aspiration needle: 1 nos. xv) reducer/ reduction sleeve (5mm): 1 nos xvi) grasping forceps (toothed & rachet 5mm): 2 nos xvii) laparoscopic knot pusher: 1 nos xviii) clip applicator (reusable): 5mm -: 1 nos : 10 mm: ino xix) uterine manipulator: 1 nos xx) clips( medium & large) xxi) drilling needle: 1 nosxxii) infiltration needle: 1 nos xxiii) biopsy forceps (toothed punch biopsy): 1 nos xxiv) myoma fixation screw: 2 nos xxv) tissue morcellator with base unit & accessories: 1 nos , dual wavelenght laserbrand- zeisstechnical specification laser type: diode, semiconductor wavelength : 1470nm+635nm max power: 15 watts/1470nm+5mv/635 aiming beam : 635nm/1, 4mw max or 515nm/2, 5mw max operation mode : continuous or modulated pulsed time : 0.05ms-1000ms beam delivery : sma905 connector optic fiber compatible : optic fibers having a core from 200um to 1000um, na=0.22~0.48 beam emission initiation : footswitch controller :microprocessor display : 10.1" ips with touch panel medical approved cooling : internal, air and thermoelectric cooling power supply of the laser: dc 24v/8.33a from the separate ac power supply of ac adapter : single phase 100-240va; 50-60hz, max 90w ac adapter dc 24v/8.33a medical approved laser dimensions: 27cm*24,5cm x 9cm laser weight: 2.75kg laser case dimensions : 53cm x 38cm x 23cm weight of laser with cases : 9kg environmental conditions during work : from +10 to 24 c degree, relative humidity from 30% up to 60% cass of medical device iib laser safety class 4 electric safety class i type b housing protection degree ip20b , hd camera setbrand- karl storz/ olympustechnical specification (i) hopkinsa forward-oblique telescope 30a, diameter 4 mm, length 30 cm, a utoclavable, fiber optic light transmission incorporated, color code ed : 1 nos(ii) telecam c3 : 1 nos(iii) image1 st hx one-chip full hd camera head, 50/60 hz, fixed focus, prog ressive scan, soakable, gas-and plasmasterilizable, focal length f = 16 mm, 2 freely programmable camera head buttons, for use with image1 x-link tc301, tele pack + and tp101 : 1 nos(iv) medical grade surgical monitor - fhd : 1nos(v) cold light fountain power led 175 scb, with integrated karl storz-scb, high-perfo
Tender For supply of laboratory equipments /laptop/printer - flash chromatography system model a1700x-200ml yamazen carporation, japan make, programmable elution modes: isocratic step, linear & rf gradient, pumping flow rate: 5-200 ml/min, maximum pressure: 1.5 mpa (15 bar/217 psi), no. of solvents: use up to 4 solvents in a gradient, uv detection: dual variable wavelength pda uv vis, detector 200-800 nm,uv detector sensitivity: 0.02-10.24 saufs, fractionation modes: time manual, peak, peak& slope (valley)02, automated densitometer with 4 reading channelsmake- genaxy/thistle/cleaverdensitometer a universal densitometer scanner with software capable of reading 144test per min. is available for band quantitation following post electrophoresis staining ordering information-cell as gel application packages equipped with bridges applicator and clinical test kit, 1x4 -specimen semi micro applicator volume applied sample band with compatible strip size: 5.7x14cm, cell as gel wet membrane bridges and densitometer, 1x8.5 cm bridge for 1x5.7x7x14cm or 2x2.5x14cm cell as gel. strip cat no. cslbg8.55 terbo scan software densitometer (excludes computer and scanner) cat no. csldens flat belt scanner for turbo scan software cat no. csscan, uv transilluminatormake- genaxy/thistle/cleaverresearch model: 312nm single wavelength transilluminator for detection of more than 0.1 ng of dna filter area (cm) uv 20 x 20cm , analytical balance make- aczet/radwag/sartoriuscapacity :220gm readability : 0.1mg repairability: 0.2mg response time: 2-3 sec pan size : 90mm display: lcd backlite calibration : motorized internal calibration, probe sonicator (touch screen) with sound proof enclosure make-labman/aczet/sonic temperature indicator and controller touchscreen display - 4.3 inches tft user password protection available microprocessor controlled and completely programmable. large lcd display with time setting. auto-tuning for convenience and optimal processing efficiency. variable power output control. auto frequency tracking output amplitude 0-100% adjustment. automatic fault alarm. frequency 20-25khz-automatic tracking process capacity 0.5-500ml (approx.) probe dia (titanium alloy) standard 6mm (1/4") display 4.3 inches tft display function temperature, power, time, etc. temperature range( c) 0-99 c timer (selectable) yes overload protection yes user password protection available input method touch screen control, data memory 20 groups output power 6.5-650w (adjustable) power supply : ac 220v/50hz, pulveriser/grinder make-ideal/mac/amccommercial dry grinder are used for grinding different types of products like spices, fresh ginger, salt, sugar, leaves, herbal products, cattle and poultry feeds, icing sugar, custard powder, instant food, food colors and allied food production. 3 hp motor deluxe model camber size: 10 x 5 cm. capacity: 20-25kg./hr., decoction apparatus gas operated decoction making machinemake-ideal/mac/amcvessel capacity: 15 liters for 1 to 5 lit production capacity, motor: /1 hp single phase motor fuel: lpg (fitted with i no. burners) all contact parts in 304 grade stainless steel complete structure in mild steel ready to use with all standard accessories wi s.s. bucket 10 ltr., s.s. mesh, & s.s. round tank, cooling centrifuge make-remi/eppendrof/thermo programable compensation for true sample temperature: yes pre cooling: yes acceleration profiles: 9 deceleration profiles: 9 & coasting fast spin: yes display: lcd control communication: digital parameters setting switches: bi-directional encoder brushless motor with frequency drive: yes inverter fault detection with auto shut down: yes cfc free refrigeration system: yes no. of programs: 99 last set parameters recall: yes choice of rpm/ref setting: rpm/rcf digital countdown timer 0-99 min & continuous run: yes automatic rotor identification: yes emergency lid lock release: yes password protection: yes gas hinge to prevent door falling: yes imbalance detection with centrifugatio