Get complete information related to latest Photovoltaic Panel Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Photovoltaic Panel Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Photovoltaic Panel Tenders.
Tender For supply and installation of 85kw ongrid solar rooftop power plant and 5 years maintenance at swm site, yadapura road, arsikere cmc limit - bos-balance of system & integrating with dashboard for real-time energy production monitoring, grid & battery performance tracking, iot-based remote monitoring & control, smart alerts & predictive maintenance, historical data & performance analytics,web & mobile dashboard access, three phase bidirectional smart energy meter and escom energy meter approval charges, application charges, agreement making and synchronization, installation of aluminum rails, solar panels and inverters. wiring from panels to dcdb, dcdb to inverter, inverter to acdb, acdb to lt panel, panel to panel loop earthing, dc earthing, ac earthing and light ninga rrest or flatlaying. and comprehesive maintenance for 5 years, aluminumrailstructure,longrailorshortrailstructurefor panel mounting. end clamps and mid clamps mounting structure using spring nut and all enboltfasteners.rivetingforeach rail with epdm layer for water leak protection., provision and installation of hot-dip galvanized earthing flats, fabricated from is 2062 grade steel with 80 100 micron zinc coating for long-term corrosion resistance. the conductor arrangement includes standard 25x6 mm gi earth flat (center folded) as the main earth conductor, along with 25x3 mm gi flat as auxiliary earthing strip, deployed for interconnection of solar inverters, modules, and distribution panels to the common earthing network, design, supply, and installation of maintenance-free chemical earthing system comprising a 3-meter long, 17.2 mm dia copper-bonded electrode with 250-micron coating. the electrode is provided with backfill compound for enhanced soil conductivity and long-term stability, ensuring low-resistance grounding suitable for rooftop pv installations and associated electrical equipment protection., provision and installation of solar-grade flexible copper earthing conductor, made from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation for outdoor durability. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable system grounding and enhanced safety in rooftop pv installations, provision and installation of solar-grade flexible copper earthing conductor manufactured from high-conductivity copper (is 8130 1984 compliant) with uv-stabilized pvc insulation. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, deployed for module mounting structure and panel earthing to ensure reliable grounding and electrical safety in rooftop pv systems., provision and installation of solar grade flexible copper earthing conductor, manufactured from high-conductivity copper is 8130 1984 compliant, insulated with uv-stabilized pvc for long-term rooftop exposure. includes 1.1 kv, 1cx6 sq.mm green-yellow coded cable, specifically designated for inverter body earthing and safety bonding within the pv system, provision & installation of frls xlpe insulated 1.1 kv aluminum conductor h4 grade, stranded class-2 power cable, optimized for solar inverter to acdb interconnection. cable construction includes black extruded xlpe inner sheath is 5831 compliant, with galvanized steel armoring providing 90% coverage for enhanced mechanical protection, designed in accordance with is 1554/iec 60189. scope covers 4c x 25 sq.mm a2xfy cable routing and termination, integrated into rooftop photovoltaic ac distributio, custom-provision and installation of solar pv compliant dc cabling system comprising tuv-certified 1.5 kv electron-beam cross-linked xlpo insulated copper conductors with uv-resistant sheath. scope includes color-coded red and black 1cx4 sq.mm cables, optimized for rooftop photovoltaic string interconnections, supply and installation 8-in8-out dcdb1000vdc,ip65,iec certified, iot-compatible for remote monitoring voltage and current , ip 65 enclosur
Tender For design, engineering, supply, installation, testing and commissioning of an alert, inform and direct system at six (6) sites - control & monitoring :- the control room shall be set up in the already constructed/available room at the pandoh dam area. this system should include a minimum 43-inch (hd) screen with an adjustable stand, capable of monitoring the operation of the siren station. it should display all feedback, including the status of being on or off, battery health, any faults etc. in the installed equipment. additionally, this system must have the capability to communicate directly with the control room to provide alerts and information in real time., for supply ,testing, designing, erection and commissioning of local station for alert, information and direct system comprising of the following hardware/software: panel/housing with power supply module. the controller, linked with all the control units through a communication and integration unit, displays the system via screens. the sirens should also be remote controlled. the control of the sirens should be according to the commands received from the remote central control station through a two-way gsm/gprs/3g/4g/lte and provision of vsat. security feature including intrusion alarm auxiliary/status control board for contact closure activation and status. the siren system should withstand outdoor environment condition & the siren assembly should be rust proof to withstand harsh and saline environmental condition. single point clicks activation & polling. status monitoring. complete configuration & reprogramming for control site. minimum 15,000 message alert notification through gsm/3g/4g/5g/lte/vsat to bbmb officials/ administrators and local residents according to requirement. programmable hot keys. communication over tcp/ip secure access with password. ethernet cable length :- the bidder shall be responsible for the supply and erection of all cabling required for the complete system, ensuring that the cables are of reputable make only and conform to the prescribed standards as per site requirements. rtu & software :- the r.t.u. and software as per the manufacturer`s design / program, the software should be suitable for controls up to 100+ sirens, the system can be expanded to accommodate changing needs. the software should be app and web based. communication between control centre and sirens. :- gsm/3g/4g/5g/lte network/vsat. pre-recorded voice messages :- live and pre-recorded voice messages in minimum 3 local languages i.e. (hindi, punjabi and english) strobe light :- high intensity led strobe light, color red, amber, green, 60-120 flashes per minute (adjustable), led life > 50000 hrs., pole/top mountable with 360 visibility preferably ip 66. alert tones & voice:- minimum 5 standard alert tones. support transmission of stored voice in siren/voice controller through wave file in memory card, remote activation. remote activation of alert tones and pre-recorded voices the voice messages will be customized, optimized for good quality for the intended location, language preferably in punjabi, hindi & english. warranty period:- 3 years., input power source :- the quantity of solar photovoltaicpanels and batteries shall be adequate to meet the systems operational requirements. only reputed manufacturers such as tata solar, vikram, waaree, reil, or equivalent brands shall be supplied. the solar panel input source shall be integrated with the required number of batteries to run the installed system continuously for a minimum duration of three (3) days under idle running conditions. this includes six (6) operational cycles per day, with each cycle lasting a minimum of twenty (20) minutes. a secondary provision for electrical input supply shall be provided to enable system operation in the event of solar panel failure or insufficiency beyond the designed power supply capacity., siren type :- bi-directional electronic siren pre-programmed audio amp
Tender For supply of fd elect solar d d - supply and installation of fd elect solar 10 kva , solar pv sub system for 10 kva , pv modules for 10 kva , lightning arrestors for array for 10 kva , lightning conductor for 10 kva , surge protection device for 10 kva , earthing for 10 kva , battery energy storage system for 10 kva , inverter subsystem for 10 kva , dc rated fuse for 10 kva , junction box for 10 kva , fire extinguisher for 10 kva , electrical cables, control wires and distribution boxes for 10 kva , supply and installation of fd elect solar 15 kva , solar pv sub system for 15 kva , pv modules for 15 kva , lightning arrestors for array for 15 kva , lightning conductor for 15 kva , surge protection device for 15 kva , earthing for 15 kva , battery energy storage system for 15 kva , inverter subsystem for 15 kva , dc rated fuse for 15 kva , junction box for 15 kva , fire extinguisher for 15 kva , electrical cables, control wires and distribution boxes for 15 kva
Tender For carrying out washing and cleaning of solar panel pv modules 19820 no's of entire solar power project area by deploying 01 no. sr. electrician (highly skilled) and 04 no. of labours for cleaning & washing of modules at berra dol solar power project smw
Tender For corrigendum : tender for supply of solar pv module : - manufacture testing inspection supply and delivery of solar pv module. complete solar pv module manufacturing including conducting all type routine and acceptance tests supply testing inspection packing and delivery to project site providing insurance of the supplied modules as per attached ntpc specification mandatory spare data sheets given in nit and directions of engineer in charge. manufacturer and type of modal shall be as per almm list. each panel shall be supplied with min. 585 wp to max 600 wp in consultation with engineer in charge. , manufacture testing inspection supply and delivery of solar pv module. complete solar pv module manufacturing including conducting all type routine and acceptance tests supply testing inspection packing and delivery to project site providing insurance of the supplied modules as per attached ntpc specification mandatory spare data sheets given in nit and directions of engineer in charge. manufacturer and type of modal shall be as per almm list. each panel shall be supplied with min. 585 wp to max 600 wp in consultation with engineer in charge. , manufacture testing inspection supply and delivery of solar pv module. complete solar pv module manufacturing including conducting all type routine and acceptance tests supply testing inspection packing and delivery to project site providing insurance of the supplied modules as per attached ntpc specification mandatory spare data sheets given in nit and directions of engineer in charge. manufacturer and type of modal shall be as per almm list. each panel shall be supplied with min. 585 wp to max 600 wp in consultation with engineer in charge. , manufacture testing inspection supply and delivery of solar pv module. complete solar pv module manufacturing including conducting all type routine and acceptance tests supply testing inspection packing and delivery to project site providing insurance of the supplied modules as per attached ntpc specification mandatory spare data sheets given in nit and directions of engineer in charge. manufacturer and type of modal shall be as per almm list. each panel shall be supplied with min. 585 wp to max 600 wp in consultation with engineer in charge. , manufacture testing inspection supply and delivery of solar pv module. complete solar pv module manufacturing including conducting all type routine and acceptance tests supply testing inspection packing and delivery to project site providing insurance of the supplied modules as per attached ntpc specification mandatory spare data sheets given in nit and directions of engineer in charge. manufacturer and type of modal shall be as per almm list. each panel shall be supplied with min. 585 wp to max 600 wp in consultation with engineer in charge.