Web Analytics Made Easy - StatCounter

Pipeline Relaying Tenders

Get complete information related to latest Pipeline Relaying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pipeline Relaying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pipeline Relaying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :43287651 Due date: 26 Dec, 202526 Dec, 2025 25.62 Lacs
Tender For water supply fund(2024-25) replacement of wornout damaged ac/psc pipe to ms /di pipe and laying water supply distribution main di pipe 300mm dia 242 rm at erode road sandeipettai to tcs nagar pirivu near for jeevanagar oht line link in tiruchengode

State Government

CTN :43164020 Due date: 29 Dec, 202529 Dec, 2025 2.23 Crore
Tender For work of providing and laying 600mm dia ms pipe line from anjaneya temple to subramanyapura lake along gubbalala main road coming under pp layout service station of aeesw-5 sub division

State Government

CTN :42873856 Due date: 17 Dec, 202517 Dec, 2025 18.57 Lacs
Tender For corrigendum : laying pushing of 600 mm dia rcc (np3) hume pipe by adopting trench less technology (e.g. jack pushing method etc) of water pipe lines including supplying and laying of 400 mm dia and 450 mm dia ms pipe line at different location on sarishathali - laying & pushing of 600 mm dia rcc (np3) hume pipe by adopting trench less technology (e.g. jack pushing method etc) of water pipe lines including supplying and laying of 400 mm dia and 450 mm dia ms pipe line at different location on sarishathali & 9 no drop gate of ecl begunia colliery under block barabani under rcfa division-i phe dte. (sl no. 3)

CTN :43220823 Due date: 24 Dec, 202524 Dec, 2025 29.48 Lacs
Tender For laying commissioning and painting of 500 mm dia main canal ms pipe line reach from 1.786 km to 2.050 km and 2.150 km to 2.450 km total 564 mtr at ramjanki pump canal banda

State Government

CTN :43180825 Due date: 29 Dec, 202529 Dec, 2025 1.23 Crore
Tender For providing, supplying, lowering, laying and jointing ms pipe line, supply, installation, testing and commissioning work of pontoon, pump set with mechanical accessories, electrical equipments and electromechanical work and electrification etc. complete work with 2 years of operation and maintenance under lifting water from dev dam through pontoon for pavagadh rwss due to dam repairing works taluka - halol, district - panchamahal

State Government

CTN :43167989 Due date: 29 Dec, 202529 Dec, 2025 2.22 Crore
Tender For work of providing and laying 600mm dia ms pipe line from subramanyapura lake to subramanyapura post office along gubbalala main road coming under pp layout service station of aeesw-5 sub division

State Government

CTN :42836264 Due date: 09 Jan, 202609 Jan, 2026 16.69 Lacs
Tender For corrigendum : laying of ms/di/upvc pipe line, restoration of damages road and supply and delivery of di specials for khaschandpur piped w/s scheme at kaliachak-i block under malda malda arsenic area w/s division, p.h.e.dte. - - laying of ms/di/upvc pipe line, restoration of damages road and supply & delivery of di specials for khaschandpur piped water supply scheme at kaliachak-i block under malda malda arsenic area w/s division, p.h.e.dte. in the district of malda.

Central Government/Public Sector

CTN :43111326 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For tender for supply of supply and installation commissiong d d -supply installation testing and commissioning of 2tr 24000 btu per hour minimum bee 3 star rated confirming to is 1392 part 2 2018 inverter type cassette split ceiling mount air conditioner having wireless remote controller led display for indoor unit motorized vertical horizontal swing controls air filters uto restart with memory features inbuilt drain pump rotary scroll hermetically sealed compressor and initial charge of eco friendly refrigerant condensor and evaporator coils of copper material suitable for operation on 230v 10 single phase 50hz ac power supply the indoor unit shall be suspended from the ceiling using threaded rods including clamps bolts nuts etc and the outdoor unit shall be mounted on floor complete as required , supply and laying of soft drawn copper refrigerant pipe of suitable size for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation including necessary brazing jointing etc as required for cassette split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 25 mm dia minimum thickness of 1 2mm pvc drain pipe along with accessories and necessary clamps with an u trap at the end as required , supply and fixing of 75mm dia minimum 18mm thickness pvc covering pipe using necessary bend colloc clamps threded rod supports accessories etc for laying copper refrigernt line electrical cable and drain line as required. , supply and installation of floor mounted powder coated ms 25 x 25x5mm l angle frame including clamps bolts nuts vibrating dampers as required , drilling of hole using core cutting machine of size up to 100 mm dia in concrete stone wall ceiling for laying refrigerant lines etc and finishing the same with cement mortar after laying , dismantling shifting of old 2tr cassette split air conditioner having indoor and outdoor units associated refrigerant pipes electrical wires and drain pipes including pump down of refrigerant. , making of necessary alteration of existing gypsum false ceiling for installation of cassette air conditioner indoor units including necessary aluminium channel support gypsum board necessary accessories including painting to match for the existing false ceiling , supply installation testing and commissioning of 2tr 24000 btu per hour and iseer value five star rated and compliance with is 1391 part 2 2018 wall mounted inverter type hi wall split cooling inverter air conditioner having wireless remote controller with led display hermetically sealed scroll rotary compressor and eco friendly refrigerant initial charge of refrigerant condensor and evaporator coils of copper material air filter with auto swing auto restart features suitable for operation on 230v single phase 50hz ac power supply the indoor unit shall be fixed rigidly on wall using necessary frame the outdoor unit shall be mounted on floor laying and interconnection of standard length copper refrigerant piping as supplied by the oem between indoor and outdoor units complete in all respects as required necessary drilling of hole and finishing the same to match for the surrounding as required. , supply and laying of beyond the standard length supplied by the oem copper refrigerant pipe of size suitable for 2tr air conditioners for interconnection of suction and liquid lines between indoor and outdoor unit with tubular thermal foam insulation for hi wall split air conditioner as required for item no 1 , supply laying of 4c x 25 sqmm frls pvc insulated 1 1 kv grade pvc sheathed multistrand flexible copper cable confirming to is 7098 pt 1 1988 along with the refrigerant lines for connecting indoor and outdoor units , supply and fixing of 75mm dia minim

State Government

CTN :43116899 Due date: 23 Dec, 202523 Dec, 2025 1.84 Crore
Tender For procurement and laying of 200mm dia d.i. k-9 / m.s. pipe for cwrm and rwrm pipe line and 100mm dia d.i. k-7 / m.s. pipe for distribution pipe line of khandapada nac for widening and strengthening of khandapada-fategarh pwd road from 0/00 to 18/030 km

State Government

CTN :43090418 Due date: 05 Jan, 202605 Jan, 2026 4.85 Lacs
Tender For special repair by laying 150 mm dia m.s. pipe line in place of 140 mm dia hdpe pipe at phulberia air valve site under kanchanpur (zone- c)
 Loading, Please wait...

Connect us via What's Up