Get complete information related to latest Plasma Expressors Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plasma Expressors Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plasma Expressors Tenders.
Tender For tender for supply of spares for water treatment plant - conductivity sensor part no 13560 item no qt , 3 way valve , part no 16649 , item no ccv 2050 , 3 way valve , part no 13361 , item no ccv 2055 , check valve , part no 13401 , item no cv 2010 , check valve , part no 13416 , item no cv 2020 , filter catridge , part no 10256 , item no f 2010 , filter catridge , part no 10305 , item no f 2020 , flow rate indicator , part no 13536 , item no fi 2060 , high pressure pump cat 2531 , part no 13111 , item no hpp 2010 , pulsation damber , part no 13048 , item no pd 2010 , ball valve , part no 16198 , item no hv 2010 , ball valve , part no 13409 , item no hv 2020 , pressure guage , part no 13518 , item no pi 2010 , pressure guage , part no 13514 , item no pi 2011 , pressure guage , part no 13504 , item no pi 2012 , membrane element , part no 17589 , item no ro 2030 , solenoid valve , part no 13451 , item no fv 2020 , solenoid valve , part no 16402 , item no fv 2060 , solenoid valve , part no 16401 , item no fv 2061 , electrical motor , , v belt , part no 13285 , vibration damber , part no 13226 , drive pulleys , pump , part no 13297 , drive pulleys , motor , part no 13288 , drive bushes , pump , part no 13271 , drive bushes , motor , part no 13264 , control relay , part no 35569 , item no d01 , expansion module , part no 33036 , item no d01-1 , comm-module , part no 35548 , item no d02 , display , part no 34283 , conductivity , part no 67449 , item no u01
Tender For supply of brush cleaning , pump tyre foot , secondary fuel filter 1 liter , lever tyre car or truck , rubber hose radiator to thermostat , rubber hose radiator to water pump , v belt 1280 mm long , screw driver 8 , element oil filter , tool kit bag canvas , shoe set rear brake , tool box , bearing frt wheel , end steering tie rod , bulb , plug and socket assy , driven plate for clutch , spider universal joint vehicular , housing friction clutch , rotary pto switch on off , fuse 5 amp , hub seal rear , rope wire steel 8 mm dia 8 mtrs long , stop light tail light vehicular , rubber hose air intake , bulb 24v , s a water pump , roof marker lamp rh , s a of pipe inj no 5 , friction washer , micro filter make micro flow , horn electrical , knob , light fog , oil seal 9 52 type a , horn signal air horn assy , filter assy shorter ii 77 mm , washer lock , engine speed sensor dg 6 , king pin , handle door , solenoid , tyre pressure gauge , main leaf with bush , speedo cable 4300 lg , assy release cable comp , major repair kit for mcyl , pump water , clip , spanner double end 8x10 , filter element primary , filter element , flasher , element fuel water seprator , sealant liquid gasket , assy wheel cyl , repair kit minor clutch mcyl , assy blade wipper , horn 12 v , assy rear view mirror , flat collar nut , radiator cap assy , front direction indicator rh
Tender For supply of various items for the dhr project entitled molecular biology applications research and diagnostic techniques - laboratory items, pc based true double beam uv-visible spectrophotometerspecification:1. optical system: czerny-turner mounting, single monochromator, double- beam system, 1,300 lines/mm, 240 nm blazed holographic grating 2. light source: deuterium lamp and tungsten-halogen lamp 3. detector: r-928 photomultiplier tube 4. wavelength range: 185 to 900 nm or higher 5. wavelength accuracy: 0.1 nm (656.1 nm) 6. wavelength repeatability: 0.05 nm 7. spectral bandwidth: 0.1, 0.2, 0.5, 1, 2, 5 nm in steps 8. resolution: 0.1 nm 9. stray light: max. 0.005 %t (220 nm nai) 10. mode: abs, %t, %r, 11. photometric range: -5 to 5 abs12. noise level: 0.00003 abs rms (500 nm) 13. wavelength slew rate: 14000 nm/min 14. wavelength scan rate: 4000 to 0.5 nm/min 15. below items must be supplied along with the main instrument:a) one pair of cuvettes, 10 mm path length, 3.5 ml volumeb) integrating sphere attachmentwavelength range: 220 nm to 850 nm or betteri) samples like powder, solid, colloidal sample, thin film etc are measured by using thisaccessoryii) minimum inner diameter of integrating sphere: 60 mmc) branded i5 pc with original os- 1 no, class ii, type a2 bio-safety cabinetspecification: 1. the bio-safety cabinets should be 4 feet width with front window must be a 10 sash opening and steel with smart coat interior 2. the bio safety cabinet must include dc motors. 3. the motor must automatically adjust the airflow speed without the use of a damper to ensure continuous safe working conditions, even without maintenance adjustments. 4. cabinet must use a pressure sensor (rather than anemometer) to detect pressure drop across the supply filter, rather than in just one point across the down flow. 5. the cabinet should display the inflow and down flow air velocities and must incorporate an led indicator, visual & audible alarm to indicate excessive hepa filters loading, blower failure, airflow speed failure, incorrect window position. 6. the front of the cabinet must be angled 10 to help minimize glare. 7. the cabinet noise level must be less than 65 db(a) for a 4-foot cabinet. 8. cabinet with lights on and fan at operating speed should consume less than 400 watts or less 9. the cabinet must automatically reduce fan/blower motor speed to 30% when the front window sash is in closed position to ensure reduced energy consumption when the cabinet is not is use. 10. uv light must be programmable to allow for specific exposure times from 0 to 24 hours. 11. the cabinet should have provision to fit taps for vacuum, water and non-combustible gas. 12. the bio safety cabinet should be nsf certified with listing on nsf website. 13. the bio safety cabinet should incorporate hepa filter of the class h 14 en 1822 or better and having minimum efficiency of 99.995% at 0.3 m particle size. 14. ventilation system exhaust and inflow air volume approx 300-350 cfm 15. audible and visual alarms for hepa filter failure, blower failure, airflow speed failure, incorrect window position. 16. the cabinet should be provided with fixed / adjustable height stand, uv light and one set of detachable arms rest and one / two electrical outlet. 17. the drain pan of the bsc should be made of stainless steel. the drain pan should not be painted, or power coated. 18. cabinet should be ce certified and declaration of moc should be provided. 19. port provision for clean and safe routing for vacuum tubing and cables throughthe side of the bsc for improved organization and work efficiency., vacuum ovenspecification: 1.volume(l): 60-802.temperature range ( c): rt+5-2503.temperature resolution ( c): 0.1(at 100 c)4.temperature variation ( c): (at100 c)5.heating power (w): 21006.vaccum range 0 ~ 1 atm7.timer: 1min ~ 99hr59min8.vaccum connector (mm): 109.venting connector (mm): 1010.inner size (mm): 400x400x40011.dimension (mm): 625x585x710, constant temperature incubators
Tender For tender for supply of bolt , screw stopper , ring packing reinforced , ring sealing/packing of indicator valve on the block , packing/gasket seal , ring sealing/packing , nozzle assembly holding bolt , turbo compressor diffuser ring rubber , turbo compressor motor locking plate , element filtering , ring sealing/packing , ring sealing/packing , ring sealing/packing , compensator k(g)-1-2.5-300 , pipe camshaft oil supply 275mm , spring , bolt , gasket , gasket exhaust flow , gasket copper for starting valve 54x45x1 , ring packing reinforced , ring sealing/packing of cylinder sleeve studs , gasket copper 15.96x22.2x1.1 , pin split/cotter 8x80-216 , bearing bush , stud , plate stop , plate locking steel , ring sealing/packing valve lever etinxhaust manifold water p , pipe feeding oil to governor drive , ring sealing/packing , gasket copper , bolt