Get complete information related to latest Plate Reader Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plate Reader Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plate Reader Tenders.
Tender For corrigendum : online tender for supply and installation of spectroflurometer multimode platereader and dried blood spot (dbs) puncher automated to institute of child health and hospital for children, chennai
Tender For supply of laboratory and scientific equipment - temperature control trainer , flow control trainer , first order and second order system , interacting and non-interacting system , computer compatible with instruments along with software.
Tender For corrigendum : supply of - electroporator and accessories- the instrument should have options for both square and exponential electrical field waveforms, to have optimal electroporation conditions for all kinds of prokaryotic systems including e. coli, agrobacterium sp. etc., should have preset, optimized programs for commonly studied bacteria and other microbial cells., should have user method/program storage for minimum 50 programs, and storage and recall of pulse parameters and results for previous minimum 50 experiments., output voltage should be adjustable in 200 v - 3000 v range with 10 v precision., should have pulse width or duration of minimum 1.0-4.0 ms with 0.1 ms precision., should have inbuilt digital interface for display of parameters, and control/setting of, time constant, pulse and actual voltage delivered for each electroporation event., to ensure precision and reproducibility of the pulse, the system should have pulse trac circuitry, and arc quenching (arq) system to reduce arcing and protect the samples., minimum operating temperature range: 01 - 40oc , accessories: the instrument should be supplied with all required accessories; minimum 01 cuvette rack, minimum 500 sterile electroporation cuvettes of 0.2 cm electrode gap width, minimum 25 ml compatible electroporation buffer etc., should be supplied with an online ups system of 3 kv for power back up., warranty: minimum three years from the date of installation., the price of the system should be exclusively quoted in inr., each part of the system supplied should have respective part number. quoted model, should be available on the website of oem/bidder., if required bidder should arrange proper demonstration of quoted model at the time of technical evaluation on their own arrangement.
Tender For quotation for probeless ultrasonicator with probeless closed tube shearing mechanism with sample rotation system and integrated water circulation cooling system to ensure high precision temperature control
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous
Tender For supply of machines and laboratory equipment?s for electronics engineering - 8051 microcontroller trainer , lcd 16x4 alphanumeric display , 4x4 matrix deypad , dac0808 8-bit digital to analog d/a convert ic package dip-16 , ic-741 , adc0808/0809 , stepper motor , dc motor , at89s52-24pi / at89s52 ic atmel 8051 microcontroller 40 pin dip mount chip 8 bit microprocessor 8kb isp(in system programming) flash memory up to 33mhz clock frequency speed , digital communication training system , advance digital communication training system , 10 khz to 3 ghz spectrum analyser with tracking generator , 100 mhz dual channel digital storage oscilloscope , a) verify the open loop transfer characteristics of op-amp using ic-741. also determine gain of b) inverting, c) non-inverting and d) buffer amplifier using ic-741 on bread board and triner kit , design wein bridge osccillator using ic-741 on bread board and determine the frequency of oscillation. wein bridge osccillator using ic-741 , design square wave generator using ic-741 and calculate the duty cycle of the generated waveform. square wave generator using ic-741 , design an astable multivibrator using ic-555 timer and calculate the duty cycle and pulse with of the generated wave form. , design an monostable multivibrator using ic-555 timer and calculate the cycle and pulse witdth of the generated waveform , design a 2nd order active low pass, high-pass, band pass and band-reject filter using ic-741 op-amp on breadboard and trainer kit , calculate the lock range and capture range of pll using ic-565 , construct sample and hold circuit using ic-741 on bread board , kelvins double bridge test kit , wheatstone bridge test kit , d.c. potentiometer kit with 12v (d.c.) standard cell , temperature transducer kit , transformer oil dielectric strength testing kit upto 30kv , ammeter 0-5a and 0-10a - voltmeter 0-300v and 0-600v , 1-$ and 3-$ energymeter testing kit , rheostats of various ranges , digital multimeter , analog multimeter , wattmeter (0-75w), (0-150w) and (-350w) , meggar , microprocessor kit (8085 based) , trainer board of junction diode , logic gate trainer board , cro 30mhz dual trace , d/t flip-flop , common emitter transistor set , analog to digital converter interface card , 4 digit seven segment display interface card , dac kit , 8086 microprocessor trainer kit for study , intel 8051 microcontroller kit with data card , a/d converters experimental kit (adc 0800 series) , led display kit with card , lcd display kit with card , interface cards for stepper motor & dc motor control , construct the circuit and plot the , characteristics of the pn junction diode, find the cut in voltage objective : to study forward & reserve characteristics of pn juncton diode. , construct the circuit and plot the characteristics of a zener diode. find the breakdown voltage objective: to study forward & reverse v-i characteristics of zener diode. , objective: to study forward & reverse characteristics of pn junction diode , construct the circuit and plot the , characteristics of the pn junction diode, find the cut in voltage objective : to study forward & reserve characteristics of pn juncton diode. , construct the circuit and plot the characteristics of a zener diode. find the breakdown voltage objective: to study forward & reverse v-i characteristics of zener diode. , objective: to study forward & reverse characteristics of pn junction diode , construct a full wave rectifier and obtain regulation characteristics without filters and with filters. compare the results objective: to study efficiency & ripple factor of full wave & bridge rectifier on application 1 of load & filters. , construct a bridge rectifier and obtain regulation characteristics - without filters and with filters , obtain the charactersics of diac and triac , simulate half wave, full wave and bridge rectifier using simulation tool like pspice/orcad/multisim. , develop circuits simulation mod
Tender For supply of epair and maintenance of security items - repair of bio metric access control , repair and service of boom barrier at squadron , repair and service of breath alcohol analyser , repair and service of laser thermal temperature sensor , repair and service of standard duplex 3 stainless steel post , repair of steel mobile barricade , repair and service of biometric attendance system