Get complete information related to latest Plc Panel Spares Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Plc Panel Spares Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Plc Panel Spares Tenders.
Tender For corrigendum : special repairs to replacement of lt panel with switch gear accessories, ber 25 kva diesel generator set and provn of 04 x all weather ac and special repair to building no p-207 under ge gangtok
Tender For bid to ras supply of urgent repair and maintenance of rmu - material and labour for routine preventive breakdown maintenance and repairing of 11 kv rating non draw out 3 way ring main unit , opening the rmu from panel and carry out the cleaning dust , repairing and checking the ac dc wiring circuit including control fuses ct and pt fuse and circuit jack , replacement and testing of defective unserviceable electrical mechanical parts as per requirement , reinserting the vcb in panel and setting of all types of relays as per load , doing all type of standard tests and calibration of different type of relays such as over current and earth fault relay , supply and fix in replacement making connection and testing of idmt numerical based overcurrent and earth fault protection relay , supply and fix cable end jointing kit for 11 kv grade cable for outdoor termination cold shrink type joint complete
Tender For supply of core switch , distribution switch , 24 port gigabit non poe access switch , 48 port gigabit non poe access switch , 8 port gigabit non poe access switch , 40g qsfp fiber modules of same make as of switches , 10g sfp plus fiber modules same make as of switches , next gen firewall ngfw , network management software nms for 100 nos of device , network access control , endpoint detection response software for 920 users. , cat6 utp cable 305 mtr , 24 port unloaded cat6 jack panel , cat6 io modules , cat6 utp patchcords of 1 mtr length , cat6 utp patchcords of 2 mtr length , dual port faceplate along with 3x3 pvc gangbox , single port faceplate along with 3x3 pvc gangbox , 12 core single mode armored outdoor fiber cable , lc lc patch cord , 24 core fully loaded liu lc lc type , 800 mm x 1200 mm 42 u smart rack with 3.5kw ac unit , 42 u free standing cabinet , 12 ru wall mount cabinet , 9 ru wall mount cabinet , pvc conduit pipe 25 mm dia conduit , pvc conduit pipe 32 mm dia conduit , 50mm high density polyethylene pipe underground , 40mm gi conduit , ofc route markers , rcc road concrete cutting and repair , digging and refilling of hard and soft soil concrete bricks. , nms sever , active directory server , backup server , centralized edr server , 20 tb usual storage scalable , automated data backup tool , 86 inch interactive display , floor stand for 86 inch display , portable thin client , laptops , 3 core 2.5 sqmm armoured power cable , 20 kva ups , 6 kva ups , integration of services and maintenance of it infra
Tender For procurement of material for the schemes of zila parishad, nalanda. - course book, magazine, fictions and nonfiction books, competitive books, novels, newspapers, comics, story telling books, biograghy and autobiograpy books, books, lrature book, drilling of borewell 300mm/250mm dia, moon climber, circular swing, 4 way dancing see saw, troo slider (gi sheet), mankey climber, swing two teater, rocking boat, parrallel bar, mgr, monitor, keyboard, mouse, printer, ups, scaner, epu, pendriive, projector, wooden laminated/aluminium modem, door/window, calling fan, led bulb, r.d. (drinking water), 15 watt led bulb, 6 to 32 amp sp mcb, 1200 mm sweep celling fan, 400 mm, 230 volt, ac exhalist fan, 381 mm, 280 volt, ac exhaust fan, 400 mm, 230 volt, ac wall/cabing fan, stablizer, 5 hp motor, 3 hp motoi, regulator, electric pvc pipe, electric five pin socket, electric two pin socket, electric five pin plug, electric two pin plug, tube light, batten, 100 mm x 100 mm x 60 mm deep pvc/metal, box, 75 mm x 75 mm x 60 mm deep pvc/metal box, 16 amp socket, fan regulator 2 module, piano fan regulator 01 module, ??? db 4 way, switch, board, installation charge, electric wire, 2 hp motor, 1.5 hp motor, 3hp statrter, 2hp statrter, 1.5 hp statrter, adapter, submersible wire, mcb control pannel, street light, high mass pole with bracket 50 watt hd light, iot device, ac 2 tone, ac steplizer, starter repair, submersible repair/new, stabilizer repair/new, pa mixer amplifier ssb-120, pa mixer amplifier cma-5400, chairman unit cmc-5100, delight unit cmd-5200, pa wall speaker asx-3128t, awm-7200u2 microphone, 15 mtr. mic wire falcon, speaker cable falcon coil 90mtr., cassette ac 3.8 tone, cassette ac 2.0 tone, copper pipe, drain pipe, four copper wire, choki stand, book self, chair, study table, news paper stand, bench, desk, office table, black board, pvc carpet, steel almirah, foldable wheel chair, battery box, steel rack, dining table, tea table, floor carpeting, visitor chair, fiber chair, 3 seater bench, high mask pole (bottom, thickness, base plate, foundation bolt, battery box, arm), lithium battery, 50 watt led, 150 watt solar panel, hire charge of air compressor machine, hire charge of boring machine, pcc cutting machine, ms angle, ms channel, ms clamp 20 mm, ms clamp 63 mm, clamp d, ms patti, ms pipe 50 mm, tank clamp, colour seat 10' x 48", colour seat 12' x 48", colour seat 14" x 48, angle rack, library table, false celling (with material), flooring (with material), paint and putty (with material), venner with glossy polish (with material), wall paneling (with material), cupboard (mr ply) (with material), furniture repairing work (with material), wall paneling louvers work (with material), sofa (with material), upvc window (with material), pvc wall paper (with material), parda (with material), pvc wall pilling, stone notice board size 2.5feet 2feet &, 2feet*1.5feet, bench, desk, office table, black board, pvc carpet, steel almirah, foldable wheel chair, battery box, steel rack, dining table, tea table, floor carpeting, visitor chair, fiber chair, 3 seater bench, high mask pole (bottom, thickness, base plate, foundation bolt, battery box, arm), lithium battery, 50 watt led, 150 watt solar panel, hire charge of air compressor machine, hire charge of boring machine, pcc cutting machine, ms angle, ms channel, ms clamp 20 mm, ms clamp 63 mm, clamp d, ms patti, ms pipe 50 mm, tank clamp, colour seat 10' x 48", colour seat 12' x 48", colour seat 14" x 48, angle rack, library table, false celling (with material), flooring (with material), paint and putty (with material), venner with glossy polish (with material), wall paneling (with material), cupboard (mr ply) (with material), furniture repairing work (with material), wall paneling louvers work (with material), sofa (with material), upvc window (with material), pvc wall paper (with material), parda (with material), pvc wall pilling, stone notice board size 2.5feet 2feet &, 2feet*1.5feet, white
Tender For repair/ replacement of unserviceable lt panel contactors relay mcb, mccbs, vfds lt cable earthing for various type of ac plant at base hospital under ge (east) delhi cantt-10
Tender For special repair to e/m services for building no p-1, lt cable for connecting power supply of 1mw diesel generator set to main lt panel at nsry power house, internal electrical works and split type ac in radio room, and other miscellaneous work under ge haddo, sri vijaya puram
Tender For custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generator panel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no