Get complete information related to latest Pneumatic Adapter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pneumatic Adapter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pneumatic Adapter Tenders.
Tender For supply of transformer with relay w o panel , panel with 25 amps contactor accessaries , transformer panel fitted with 25 amps contactor , 25 amps contactor with 110v coil , thermal overload relay , hrc fuse base with carrier , hrc fuse link 10 amps , test reset micro switch , 25 amps rev isolator with handle , overload reset actuator assy , test reset spindle assy with key , isolator handle interlock plunger , octal base wiring for pilot , octal base wiring for e l , pilot relay 12v d c , pilot relay 12v a c , diode d1 , diode d2 , condensor 16v 220 mfd , 30 amps plugand socket complete , socket housing with dmc insulator and brass pin contact , octal base 8 pin relay base , 300amps contactor with coil , main moving and fixed contacts for 300amps contactor , 150amps plug and socket complete , lamp holder for e l indication , indicating lamp , micro switch for start , micro switch for stop , potential transformer 40va pt , potential transformer 80va pt , epoxy moulded potential transformer 100va , hrc fuse link for control , sensitive earth leakage relay with cbct and p t , transformer panel fitted iwt 25 amps contactor complete , 25 amps contactor with 550v coil , hrc fuse base with carrier 20a , start stop e l test reset micro switch , push actuator for start stop e l testandreset , e l trip indication lamp with holder , slide lock fuse 15a , isolator 100amps 2 pole on off , dmc moulded copper flat terminal for i c and t g 300amps , man moving and fixing contacts for 300amps contactor , u v coil for 300amps contactor , 3 pole magnetic o l relay w o ct , ct for o l relay , core balance current transformer , ct operated 72mm dia ammeter w o c t , micro switch for e l test or reset , hrc fuse link 10amps , e l trip indication lamp , isolator 50 amps 2 pole on off , interlock assembly for isolator handle //bid details 2 / 62
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair
Tender For corrigendum : supply of replacing in 1.5or2tr ac unit blower fan motor , replacing in 1.5or2tr ac unit blower drum , replacing in 1.5or2tr ac unit condenser motor , replacing in 1.5or2tr ac unit condenser fan blade , replacing in 1.5or2tr ac unit pcb of indoor , replacing in 1.5or2tr ac unit pcb of outdoor , replacing in 1.5 ac unit rotary compressor 1.5tr , replacing in 2.0 ac unit rotary compressor 2.0tr , replacing in 1.5or2tr ac unit capacitor 25 35 5 mfd , replacing in 1.5or2tr ac unit 25a 2 pole contactor , replacing in 1.5or2tr ac unit terminal box 6w , water service of 1.5 or 2 tr ac units , blower service of 1.5 or 2 tr ac units , gas charging r22 r 134 of 1.5 or 2 tr ac units , replacing 50mm thick filter , s f of auto controller of 2 ac , replacing 25a spn mcb , site visit for ac repairing
Tender For power contactor 110 amp. 4 pole 415 v ac coil voltage 380-415 v ac 50 hz with 2 nc au x contact along with surge suppresor as per s.no.59 & item no. k-08, place of installation s1k43 of bill of material of rdso spec no. rdso/pe/spec/ac/0184-2015(rev.0), used for main contactor fo r local main supply of lhb type ac coaches , confirming to rdso spec. no. rdso/pe/spec/ac/0184-20 15(rev.0) suitable for lhb type ac coaches switch board cabinet.(s1k-43) specn: rdso spec no. rds o/pe/spec/ac/0184-2015(rev.0) [ warranty period: 30 months after the date of delivery ]
Tender For supply of 3 pole power contactor mnx32 model of l&t makes to catalogue no. cs94111 ha ving rating of 55 amp and coil voltage of 415v ac or similar ]
Tender For supply of ffd1 a ac input fuse fail detector circuit, mt 111, 415v12v dc,con101 a 3 pole ac input mains contactor, mnx 70 cs97076booo,63a,230v ac 70a,tr2a control transformer class b insulation with temperature rise class a 415240v ac, 500va,converter 1a,2a ac to dc converter,lrs 100 48 , ip 230vac, op 48v dc2.3a,tr1a three phase, double wound, impregnated naturally air cooled, mains transformer class h insulation and temperature rise limited to class f, input power transformer,32.15 kva, 45670v, 70v,ipt 1a inter phase transformer,0.65kva,ffd2a 3a, rectifier fuse fail detector circuit modified for latching facility using one extra relay and pb mounted on same pcb card used for trip function, mt 111,70v ac, aux. supply 12v dc,mr1a 2a 3 phase, full controlled, full wave rectifier bridge comprising of scr with heat sink and surge suppression networkt250e160,scr 170a1600 piv, 250a1600 piv,df a free wheeling diode,150nd160,150a1600piv,ffd5a free wheeling diode fuse fail detector circuit modified for latching facility using
Tender For supply of contactor 3 pole, 32 amp. capacity suitable for 690 v, 50 hz ac, coil voltage 77-143 v dc with auxiliary contact 1 nc with surge suppressor as per rdso common bill of material vide rdso letter no. el/7.1.108/mssbc dt. 17/09/21 to abb model no. tal 30-30- 10+rv5/250 or schneider model no. lc1d32fd or l & t model no. mdx32 or siemens model no. 3rt20271bf40+3rt29261jl00. [ warranty period: 30 months after the date of delivery ]