Tender For supply of contral valve , shut off cock , fuel pump electrical , cabin mounting pad , fan belt alternator , side box , hand brake valve assy , radiator assy , auxiliary water tank , main cylinder dia 22
Tender For corrigendum : supply of carrier roller assy for dozer , pressure plate assy for dozer , relief valve assy for dozer , valve assy for dozer , valve fuel shut off for dozer
Tender For supply of purg o mate automatic float air vent valve shut off valve having thread bsp-3/8 inch, 10 bar, 10 degree centigrade and hexagonal ss reducer size -3/4 inch x 3/8 inch to rcf drg. no. lw6315 0 at. e. ltem no. 4 & 7. matl. & specn. as per drg. [ warranty period: 30 months after the date of del ivery ]
Tender For supply of hq locking and guide coupling , nq locking and guide coupling , hq innertube latches with spring , nq innertube latches with spring , hq overshot lifting dog with spring , nq overshot lifting dog with spring , thrust bearing 51115 , thrust bearing 51114 , deep groove ball bearing 6309 , bearing 3210 , thrust bearing t6 , thrust bearing t8 , thrust bearing t10 , hq shut off valve nylon , hq landing ring , nq shut off valve nylon , nq landing ring , water swivel packing , water swivel wash pipe
Tender For corrigendum : supply of boq bid - top block assy 32 cfm, part no. x020007b , air pressure switch rt116, part no. 4106016510 , air- filter regulator lubricator 1 in bspt, part no. 4106016638 , non return valve, part no. 4106016633 , shut off valve, 1 in, bspt, part no. 4106016634
Tender For corrigendum : special repair for renewel of e/m items and plant/ machinery held in charge of age (e/m) rnd agra cantt under ge (i) rnd delhi - supply , installatation , testing and commissioning of diesel driven generating set to give an out put of 500 kva, 415v ac supply 3 phase, 50 hz, 4 wire radiator mounted on common base plate complete with fuel tank, vibration damper and other accessories with fuel tank viberation damper and other accessories with acoustic enclouser as per latest cpcb-iv norms and amf panel including pcc foundation work as per oem reccommandation and taking out the old dg set from the location and deposited to mes store yard complete all as specified and directed, interanally comprising of following :-(a) diesel driven engine :- developing a net output suitable matched to give a net rated output of minimum 604 hp/suitable to drive 500 kva alternator, at 0.8 power factor 415 volts. the engine should be capable of delivering the required output at 1500 rpm, water cooled, self start, with a provision of 10% overload for one hour in every 12 hours with the following accessories and all as specified.(i) fly wheel to suit flexible coupling and fly wheel housing.(ii) air cleaner complete as per manufacturer specification. (iii) fuel injection pump. (iv) flexible coupling with guard, nuts and bolts.(v) fuel filter with mounting. (vi) oil filter with mounting.(vii) starter motor as per manufactures design.(viii) exhaust, silencer industrial type with exhaust pipe suitable length.(ix) batteries 12 volts 2x180 ah maintenance free batteries with copper lead, terminals etc.(x) instrument panel complete with microprocessor based controller comprising shut down valve indication, lcd hour counter indication, rpm indication , led lamps for fail to start, over speed /under speed . low lub oil pressure, high engine coolant temperature. gaugae.(xi) dynamo/alternator suitable rating., (b) alternator :-the above engine will be coupled through flexible coupling on an indigenous alternator mounted on a strong steel fabricated common base frame suitable for mounting in an acoustic enclousre. the alternator will be 3 phase 50 hz 1500 rpm self regulating self exciting type and have class h insulation of stator and rotor windings and generate 500 kva output at .8 power factor 4 wire 415 volts ac supply under ntp condition with a provision of 10% overload for 1 hour in every 12 hrs running. the alternator would be screen protected and fitted with shield ball/roller bearing, automatic voltage regulator.(c) control panel :- s&f amf (automatic on mains failure) control panel cpri approved outdoor ype kiosk water, dust and vermin proof and fabricated out of 3.15 mm thick crca sheet and 50mm x 50mm x 6mm angle iron powder coated suitable for 415 volts 3 phase 50 hz ac supply with and incl the following :-(i) mccb of suitable capacity(ii) necessary relays, times and power contractors of suitable rating/capacity for auto on-off the dg set and changeover of the load in case of power failure.(iii) digital mulfifunctional meter for phase wise reading of amps, voltage kwh and frequency -01(iv) internal wriring with single core solid copper conductor cable of appropriae gauge incl mumbering ferrules and control fuses.(v) earthing terminals 02 nos(vi) auto/manual start switch to by pass auto start.(vii) battery charging system suitable for charging for charging the battery provided with the dg set incl boost/stickle switch and system, dc voltmeter digital type., (d) fuel tank :- one no built in sheet metal steel tank mounted inside the acoustic encloser and of adequate capacitynot less than 740 ltr with inlet and outlet connection including the following :-(i) level indicator with float and gauge.(ii) fuel piping for fuel supply to engine and over flow to tank(iii) fuel strainer(e) acoustic enclosure :- enclousre be designed for reducing the sound level up to 75+/ 5db (average) as per is 8528 part 10 and as per approved cpcb morms. the acous