Get complete information related to latest Pole Isolator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pole Isolator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pole Isolator Tenders.
Tender For tender for supply of protection relay for motor , pt epoxy 6 6kv 3p 500va wi lmb 110 220v , voltmeter analogue 72 sqmm , limit switch , ht fuse 125 amp 6.6 kv power fuse , vacuum contactor coil hold on , rectifier 1p 11 0vdc , ct 50 5 5 va f amtr ring type , vcum cntctr asly 400a 6.6kv 85 230vac dc , pneumatic type on delay timer 0 30 sec , push button actuator with 1 no , push button actuator with 1 nc , yellow push button , red push button , elr defnt time w cbct 110v 0 8a 0 15s , control cbls w accssrs 1 1kv 2 5mm2 , ammeter 72mm2 0 50 150a , delay timer electronic 0 30 s , isolator off load , ht cable 6 6 kv , relay ve phs falur prvntn w u o vltg , insulators complete set
Tender For corrigendum : supply of 415v, utilization category ac23a, 630a local isolator cabinet in sheet steel enclosure complete with 630a, 3 pole load break switch. 2. shall be with side operated handle, padlocking facility, prebreak micro switch having 1no+1nc contact. 3. micro switch contacts shall be wired to 4 sq mm tb for external termination. 4. provision of padlock system having sufficient space to lock the isolator at off position by minimum two agencies at a time. 5. complete with both power & control circuit wiring with all insulators, bus bars and control terminal blocks. 6. detachable bottom gland plate for entry of cables from bottom. 7. front door shall be hinged and inter-locked with the isolator in 'on' position. the front door should have a minimum 3 mm thickness perspex/triplex window for observation of position of contacts. 8. isolator should confirm to iec 60364 standard. 9. the dimensional drawing of the local isolator cabinet or product catalogue showing mounting arrangement of the components should be enclosed along with the offer. 10. isolator cabinet should be provided with rain canopy. 11. any isolator parts should not be made of aluminium/aluminium alloy. 12. isolator cabinet shall be metal enclosed suitable for wall fixing using 4 welded fixations, dust and vermin proof and shall be provided with degree of protection as ip-55. 13. provision for three distinct parallel busbar per phase for termination of three nos of 240 sqmm aluminum cables for incoming and two distinct busbar per phase for termination of 120 sqmm copper cable. 14. all hardware used in isolator cabinet shall be corrosion resistant. 15. minimum clearance between the live parts and detachable bottom cable gland plate shall be 400mm. 16. cabinet should be painted with alkaline resistant epoxy paint. 17. isolator cabinet shall have provision for earthing at two separate and distinct points. 18. each isolator cabinet should be supplied with panel keys., push button station specification: 1. pbs made of 2mm sheet steel enclosure with rain canopy, protection: ip-65. 2. 01 no. of green colour start pb with 1no+1nc contacts, 01 no. of red colour stop pb with 1no+1nc contacts, 01 no.of increase pb with 1no+1nc contacts <(>&<)> 01 no.of decrease pb with 1no+1nc contacts. one emergency stop push button with 1no+1nc contacts (push to lock type) shall be provided. size of each push button is of 22.5mm diameter. inscription plate for all push buttons. 3. pb shall be wired with 2.5 sq.mm. copper wire to 40 nos. serially numbered terminal blocks (tb) of elmex make having tb-5-6, 7-8, 11-12, 13-14 <(>&<)> 17-18 shorting link. 4. two nos. of cut out of size 72x72 mm for ammeter and rpm meter shall be provided. 5. 'on','off' <(>&<)> 'trip' indication led lamps in red, green <(>&<)> amber colour respectively with inscription plate to be provided. 6. all push buttons, elements, led lamps <(>&<)> cutout for ammeter <(>&<)> rpm meter shall be on the hinged door of the pb station. 7. pb station shall be weather proof, neoprene rubber gasket suitable for outdoor application. 8. 2nos. of earthing studs to be provided. 9. left side hinged door shall be provided with flexible braided copper earthing. 10. pbs shall have 04 nos. of corrosion free bracket suitable to fix on vertical surface. 11. detachable gland plate to be provided. 12. the push button shall be painted with one coat of red oxide primer <(>&<)> two coats of zinc chromate primer and finally finished with stoving enamel grey paint. 13. the push button station shall be generally in line of enclosed drawing (fig-2). 14. party to submit the drawing along with the offer for technical scrutiny.
Tender For supply of electrical materials on annual rate contract - 1.5 sq.mm f.r copper pvc insulated wire., 2.5 sq.mm f.r copper pvc insulated wire., 4 sq.mm fr copper pvc insulated wire., 6 sq.mm fr copper pvc insulated wire., mains with isi mark wp 2 x 2.5 sq.mm. 1100 v grade aluminium pvc insulated cable., mains with isi mark wp 2 x 4 sq.mm. 1100 v grade aluminium pvc insulated cable., mains with isi mark wp 2 x 6 sq. mm.1100 v. grade aluminium pvc insulated cable., retrofit t8 led 18 / 20 tube light., ceiling rose / batten holder /slanting holder /hanging cord switch / hanging bell push/ pendent holder bakelite base 6a., street light bracket made from 25 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., street light bracket made from 32 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., street light bracket made from 40 mm. dia b classg.i. pipe, 0.6m. in length with clamps for suitable pole., condenser 2.5 micro farad for ceiling fan., ceiling fan of 600mm. sweep complete, ceiling fan of 900mm. sweep complete, energy saving ceiling fan 230 v a.c. 50 cycles 1200mm complete, ceiling fan 230 v a.c. 50 cycles 1400 mm complete, double pole metal clad switch with hc type fuse 240v, 63a, triple pole metal clad switch and fuse 415v, 100a, spmcb 0.5a to 5a, c-series, spmcb 6a to 32a, b- series (for lighting), spmcb 40a to 63a, b- series (for lighting), tpmcb 6 a to 32a, 3 pole mccb upto 100a, 415v, with short circuit rating 25 ka (ics=100% of icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ uv/ trip alarm contact and mccb should have phase barriers both sides, in provided enclosure, hc pattern porcelain fuse bridges with base & hc type fuse links 240v 16a erected on polished wooden block complete, hc pattern porcelain fuse bridges with base & hc type fuse links 240v 32a erected on polished wooden block complete, porcelain fuse bridges with base hc type fuse links 240v 63a erected on polished wooden block complete, porcelain fuse bridges with base hc type fuse links 415v 100a erected on polished wooden block complete, xlpe armoured cable 2 core 6 sq.mm. aluminium conductor with continuous 5.48 sq. mm, xlpe armoured cable 2 core 10 sq.mm. aluminium conductor with continuous 5.48 sq. mm, xlpe armoured cable 3 core 25 sq.mm. aluminium conductor, xlpe armoured cable 4 core 6 sq.mm. aluminium conductor, xlpe armoured cable 4 core 10 sq.mm. aluminium conductor, xlpe armoured cable 4 core 16 sq.mm. aluminium conductor, gi earth wire of high purity of different sizes used for earthing or any other purposes, providing pair of duly tested rubber hand gloves as per is:47705 suitable for working upto 22 kv supply complete., ding dong / electronic musical type call bell with heavy duty coil suitable to operate on 230v a.c., electronic type cordless call bell erected on t.w. board having portable bell push working on 9v d.c. battery and (effective range upto 45 meter) bell on 250 v a.c.supply, electronic type step regulator for ceiling fan 600/ 900/ 1200/ 1400 mm. sweep, complete, double poleisolator only switch version of miniature circuit breaker of 40a, triple poleisolators only switch version of miniature circuit breaker of 63a, triple poleisolators only switch version of miniature circuit breaker of 100a, quartz electronic time switch having 24 hour dial to work on 250 v 50 cycle ac having built in rechargeable nickel cadmium batteries to run the time switch on failure of supply having switch contact rating up to 16a to use independently or in conjunction with contactor., two pole power contactor 230 v, 12 a for time switch complete, two pole power contactor 230 v, 32 a for time switch complete, four pole power contactor 430 v, 16 a for time switch complete, four pole power contactor 430 v, 40 a for time switch complete, programmable digital almanac timer microcontroller based with real time clock to operate on der
Tender For supply of 25 kv ac, 1250 a single poleisolator without earth switch as per rdso spec no. ti/spc /psi/isoltr/0210 (july%u201921) with a&c slip no. 1 or latest. [ warranty period: 30 months after t he date of delivery ]