Web Analytics Made Easy - StatCounter

Poly Pipe Tenders

Get complete information related to latest Poly Pipe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Poly Pipe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Poly Pipe Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

CTN :40844589 Due date: 10 Jul, 202510 Jul, 2025 NA
Tender For supply of polyethylene pipes for water supply

Central Government/Public Sector

CTN :40795310 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

Central Government/Public Sector

CTN :40795675 Due date: 02 Jul, 202502 Jul, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

State Government

CTN :40756934 Due date: 02 Jul, 202502 Jul, 2025 10.04 Lacs
Tender For supply and installation of some articles to the residential office of the honble deputy speaker, tripura legislative assembly, bardowali, agartala during the year 2025-26 - providing of split type high wall 2.00 tr (rated cooling capacity should not be less than 6,000 kcal/hr or 24000 btu/hr or 7000 kw) split a.c. machine with inverter compressor technology operating on non-cfc refrigerant (r-410a/r-32/equivalent refrigerants) suitable for wall mounting conforming to is:1391 (part-ii) specification (evaporator & condenser must be of pure copper) not less than 3 (three) star rating (latest standard), operates on single phase 230 volt, 50hz, ac supply maximum current drawn 11.0 ampere, including supply of 3.0 mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (four) core electrical connecting cable, remote control unit in/c batteries, 16 amps power top etc complete, capable of performing a) cooling b) dehumidifying c) air circulation d) filtering as per direction of the engineer-in-charge., standard installation of 1.5 tr/2.00 tr capacity high wall split air conditioner i/c providing of electrical plug top of required capacity, flling up/ repairing of drilled portions by cement mortar, painting etc. as per direction of the engineer-in-charge., fabrication of m.s. platform for placement of condensing unit by using m.s. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the engineer-in-charge., providing hard pvc pipe of best quality of 25 mm diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the engineer-in-charge., supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line between indoor and outdoor units (for 1.5 tr & 2 tr ac) beyond the standard length as per direction of the engineer-in-charge. (if required), providing and connecting electric control cables between mcb to indoor/outdoor. 3c x 2.5 sq. mm copper cable., supplying & fixing of 1200 mm sweep white color ac ceiling fan capacitor type double ball bearing complete with 300 mm down rod, canopies, shackles, 3nos blades, including wiring the down rod with 2x1.5 sqmm pvc insulated copper conductor cable(fr) (isi marked, bee 1 star/minimum service value 4.0 m /min/w): -, supplying and fixing of 20 mm dia extra down rod (gi pipe medium guage) with necessary hole for installation of ceiling fan as required., wiring for light/fan/ exhaust fan/ call bell point with 2x1.5 sq. mm pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ walt complete with 6/10 amps modular type switch, cover plate, gl box including necessary connection etc. as required, supplying and fixing of the following modular accessories including necessary connection etc. as required 3/6 pin 16/20 amps socket outlet (2m), supplying and fixing of the following modular accessories including necessary connection etc. as required4 step fan regulator (1m), supplying and fixing of the following modular accessories including necessary connection etc. as required20/25 amps single phase motor starter switch (2m), wiring for circuit/sub-main with the following sizes pvc insulated copper conductor cable (fr) in pvc conduit (medium gauge) recessed in slab/ wall etc. as required, earthing with 40 mm dia g.i. earth pipe (medium gauge) 4.5 m. long complete with masonry enclosure on top cl cover plate size 12"x 12" having locking arrangement including cc work, holes on earth pipe etc. as required, proving and fixing/drawing of 4.06 mm dia (8 swg) g.i. 10 wire on surface or in existing g.j/pvc/ polythene pipe for loop earthing as required., executive desk with return unit, size: 2100(w)x 2250(d) x 750 (h) mm, executive revolving chair, visitor chair, godrej 4 door bookcase (1742 h x 914 wx 320 d) mm

CTN :40611403 Due date: 21 Jun, 202521 Jun, 2025 NA
Tender For bid to ras bid to ras repair, maintenance, and installation of plant/ systems/equipments (version 2) - defence area; repair/maintenance old unserviceable critical equipment chemical earthing; service provider.-1) m & l for replacement of old defective earthing by providing new chemical earthing comprising copper earth plate electrode 900 x 600 x 5 mm thick burried directly in ground, earth pit not less than 5.10 metres below normal ground level and complete size of pit shall be 1.60 m x 1.60 m x 5.10 metres, with top edge of the plate not less than 3.75 metres below normal ground level, earth plate surrounded from all sides by 20 cm thick.salt, chareeal dust, magnisium sulphate and enhancing back fill compound (powder) suitable to increase the earth resistant value filling in alternate layers of 20 cm thick up to 1.8 metres height and including connected to copper strip 32 x 6 mm (upto 7.5 metres) by means of brazing / coppers nut-bolts, earth strip protected with 65 mm bore light grade pipe from electrode and upto test point, 15 mm bore watering pipe light grade gi funnel, wire mesh, including excavation, removal surplush soil to a distance not exc. 50 m, pcc pit in pcc (1:3:6) type c-1, using 20 mm graded stone aggregate, rcc cover 40 mm thick in rcc (1:2:4) type b1, using 20 mm graded stone aggregate reinforced with 8 mm dia mild steel deformed bars @ 75 mm centre to centre both ways complete all as specified and directed, 2) s&f test point termination block made of gun meetal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex head screw complete all as specified and directed, 3) earth continuity conductor or main earthing lead fixed to wall on battern or recess of chases or burried in ground or drawn in conduit/pipe of size 20 x 3 mm copper strip complete all as specified and directed, 4) s & f high density polyethylene pipes (hdpe)of dia 40mm as earthing contunuity protection laid in trenches/wall/floor complete all as specified and directed.

CTN :40756056 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

Central Government/Public Sector

CTN :40755481 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

Central Government/Public Sector

CTN :40755719 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

Central Government/Public Sector

CTN :40770803 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)

Central Government/Public Sector

CTN :40755708 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of polyethylene pipes for water supply (q4)
 Loading, Please wait...

Connect us via What's Up