Tender For auction sale of depot miscellaneous scrap - plastic 98417022 %u2013 plastic/pvc/nylon scrap: plastic, pvc and nylon scrap released from assorted coach,fiber guard, electrical and general railway applications including high pressure hose fibre, fan blade nylon, plastic fan blades, polycarbonate sheets, frp sheets, pvc sheets, capacitor and ballast cut pieces of polycarbonate sheet, led covers, tricolor led torch, signal torch, plastic torch, helmets including safety helmet and riot control helmet,water tank,plastic for rail, ear defender fibre, plastic insulator, plastic grab handles of emu coaches, plastic gallons, plastic caps, plastic pipes, toilet pipes, hose pipes, plastic nozzles for sink, nozzles, water taps, hand wash dispenser, buckets, plastic drums,signal unit plastic, plastic bottles,junction box fiber (attach some ms), printer cartridges, plastic bins, dustbins, plastic chairs, foldable tables, toilet stands, bottle stands, plastic table wheels, break pads, liners, ptmt scrap, fibre scrap, fibre plastic items, dac covers, released pvc/frp fibre signal bond covers, clock 300 mm dia, ac coach tube light strips and fibre mix, stripped ac coach tube light covers, water purifier parts, tree pruner, measuring torch tape, ohe discharge rod plastic portion, disaster management plastic items, miscellaneous plastic covers and materials, plastic scrap pieces and other assorted plastic items, material may contain minor ms and steel attachments, all materials unserviceable and not fit for railway use, sold on as is where is basis, loading by purchaser, custodian: dms/scrap/pardi.
Tender For tender for supply of ht cable -m and l for searching fault location of ht ug cable 11000 volts laid in trenches ducts with the help of electronic fault locating machine comprising of surge generator pulse echo fault locator with frequency distance calculator etc incl transportation of machinery excavation in normal soil strata exposing the cable fault removal of deteriorated portion of the cable treating of cable of any size including disconnecting and re fixing cables with lugs as per direction of engineer in charge note a charges of cable fault locator and dg set including transportation charges deemed to be included in the quoted rate b necessary testing of cable after making joint will be deemed to be including in the cost of relevent item , supply jointing and testing indoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120 minus 185 sqmm xlpe cable of 11000 volts e grade complete all as specified and directed note cost of cutting of existing end termination joint deemed to be included in unit rate , m and l for cable jointing kit for 11 kv earthed grade cable for straight through cold shrink type complete with joining material and accessory suitable for 120 to 185 sqmm 3 core xlpe armored aluminum conductor cable complete all as specified and directed , supplying and laying in repair xlpe insulated screened pvc bedded galvanized steel strip or wire armoured , electrical power cable heavy duty with aluminum conductor 11000 volts grade cross sectional area 120 sqmm x 3 core complete all as specified and directed , supply and fixing in repair mccb 400 amps 3 pole 415 volt 36 ka including under voltage over voltage relay with adjutable thermal setting 80% minuse 100% all as specified and directed , m and l for complete repairing serviceing of ht 11 kv vaccum circuit breaker vcb after disconnecting of all incoming and outgoing connection checking finding of the defective spare parts removing of all moisture content with suitable grade chemical replacement of rusted nuts bolts and washer replacement of all unserviceable post insulator and repair of all busbar joints and covered with ht insulation tape complete external surface as per existing colour and quality replacemnt of all defective internal ac dc circuit wiring repair servicing of breaker trolly including motorized operating mechanism ct pt power pack and calibration of triping relays system and tripping mechanism for regulating the fault flow over current earth fault differential in sequence from down streem to receiving sub stn for accuracy and effective functioning of vcb complete all as specified and as directed note nuts bolts washer cleaning material insulation tape copper wire for circuit wiring and defective ht 11 kv 2 amp fuse carrier oiling greasing to charging spring replacement of hrc fuse 110 220 volt 5 amps setting of over current earth fault relays complete other minor items for repair of breaker shall be deemed in qouated rate replacement of major unserviceable spares accessories shall be measured and paid separately under relevant items , supply and fixing heater 230 volts ac 60 watt for 11 kv ht vcb panel complete all as specifed and as directed make heatco vileco electrical , supply and fixing in replecement of spring charging gear for 11kv vcb panel suitable for 630 400 amp complete all as specified and directed , supply and fixing vacuum interputer for ht11 kv vcbs 630 400 amps brakding capacity 13point 1 ka suitable for alstom make vcb complete all as specified and as directed , taking down and repairing overhauling of air break gang operated switch with do fuse unit 200 amp 400 amp capacity triple pole mechanically operated mounted on insulators and steel frame installed vertically horizontally replacement of broken worn out components oiling and greasing of mechanical moving parts smoothing and polishing of electric contacts with providing conducting jelly of contacts refixed the sam
Tender For supply of auto electrical spares d d -armature , solenoid switch , field coil 6 , drive assy. , brush plate , carbon brush , bush for nose housing , bushing lever , bushing ce frame , nose housing , hsg lever , frame c. e. , term plate assy , contact assy , term or stud motor , stud , pole screw , bushing package or insualtion for field terminal kit , seal oil lever side , insulator for brush plate assemby , insulator for field coil , washer break , washer thrust , shift lever assy , lead ce term to solenoid , gasket ce inspection plug , pole shoe , wick - ce frame , wick - nose housing , shaft lever , o-ring ce frame , o-ring , o ring , cup plug , retainer - plunger top side , plunger , space washer - de side , nut and washer for field terminal , screw for nose housing attach , field coil , drive assy 12te , switch soleniod , brush plate assy , brush carbon , lead ceterm , housing lever , bushing ce housing , bushing - lever housing , bushing- nose housing , contact , stud battery terminal , lever shift , insulator - field terminal , insulation ce term , screw washer assy , ce housing , plunger , connector , insulator , o ring , oring , brake washer , screw and washer assy - ce housing atatch , wick -ce housing , wick -nose housing , insulator field coil ce side , housing rectifier with bearing , race for roller bearing inner , frame d. e. with bearing , regulator , diode , rectifier bridge assy , field coil support , rotor assy , stator assy. 75 a , fan assy , end cover , retainer plate , bushing for rectifier housing , battery terminal , relay terminal , term package , service package - hardware kit
Tender For supply of electrical spares for vaccum circuit breaker and starter e e -electrical release coil assly 110 volt part no- v 0022 , aux. switch ass 4no plus 4nc part no- v 0024 , flex connector 6. 6 kv vcb 65. 5 ka flc800 a part nov 0028 , vacuum interrupter 65. 5 ka, vcb, 6. 6kv part no-v 0048 , operating mechanism 65. 5 ka vcb part no- om 009 , trip neutal close switch trip normal close 25a,440 v part no- p 0045 , earth leakage relay 2-5a, aux supply, 110 v ac part no- p 0049 , resin class ct class isp10 or ci10 18. 4 ka, cl-1,5p10, 400-200 or 5a part no- p 0056 , auxiliary contactor 110 vac 110 ac,2 no plus 2 nc part no- p 0061 , idmt relay 3 over current, 1 earth fault, aux volt 110volt, ac or dc or 5a part no- p 0083 , ammeter 96cm x 96cm part nofsv 00104 , voltmeter ctr-200-100 or 5, 96cm x 96cm, 3. 3 kv or 110 v - 5 no. 6. 6 kv or 110 v-5 no. part nofsv 00105 , coil for vacuum contactor 110vdc 110 v dc part no- v 0049 , auxiliary switch assembly 2no 2nc piano type part no- v 0050 , drive insulator for vcb for 25ka, vcb part no- v 0051 , resistance for vacuum contactor 100 ohm part no- v 0060 , tie rod end for vaccume contactor part no-v 0067 , indicating lamp 110 v, dc, red and green part no- p 0043 , push button switch spring return type part no- p 0044 , ammeter or voltmeter selection switch 25 a, 440 v ac part no- p 0046
Tender For 4. ????? ??????? ??????? ????? ? - 4. electrical supply work. - led bulb 7 watt make group i (gm, havells, bajaj, philips) , led bulb 15 watt make group i (gm, havells, bajaj, philips), , pvc tape roll isi mark " (wonder, steelgrip), , main swith 100 amp panel (lt, schneider electric, ls), , main swith 200 amp panel (lt, schneider electric, ls), , xlpe insulted cable of 1.1 kv grade with aluminum conductor armored/unarmored make group i-25.0 sq.mm. x 4 core isi mark (abb, polycab), , xlpe insulted cable of 1.1 kv grade with aluminum conductor armored/unarmored make group i - 16.0 sq.mm. x 4 core isi mark (abb, polycab), , xlpe insulted cable of 1.1 kv grade with aluminum conductor armored/unarmored make group i - 10.0 sq.mm. x 4 core isi mark (abb, polycab), , xlpe insulted cable of 1.1 kv grade with aluminum conductor armored/unarmored make group i - 6.0 sq.mm. x 4 core isi mark (abb, polycab), , xlpe insulted cable of 1.1 kv grade with aluminum conductor armored/unarmored make group i - 6.0 sq.mm. x 2 core isi mark (abb, polycab), , ab cable (aluminum) - 25 sq.mm. x 1 core isi mark, , ab cable (aluminum) - 25 sq.mm. x 2 core isi mark, , ab cable (aluminum) - 18 sq.mm. x 1 core isi mark, , fr pvc insulated flexible aluminum coil (90 meter length) 2.5 sq.mm. x 2 core isi mark, , fr pvc insulated flexible aluminum coil (90 meter length), , 1.5 sq.mm. x 2 core isi mark, , fr pvc insulated flexible copper 1.5 sq.mm. x 2 core isi mark, , kit kat fuse 100 amp with base, , supply & fixing solar traffic blinker as per specification, , all in one solar street light with sensor - 20 watt, mail: she, , all in one solar street light with sensor - 30 watt, , all in one solar street light with sensor - 40 watt, , solar road stud, , 3m cat eye, , mcb-16 amp (lt, schneider electric, ls), , mcb-40 amp (lt, schneider electric, ls), , mcb-100 amp (lt, schneider electric, ls), , timer (lt, schneider electric, ls), , contactor 100 amp., , contactor 25 amp., , submersible flat 3 core x 6 sq. mm copper cable, , shackle type insulator, , pin type insulator, , street light fixing pipe and clip with nuts bolts set (material-mild steel)
Tender For supply of electrical items c c- fixed contact assembly , stator , moving contact assembly , isolator on off , bushing insulator with stud , line tester , hnd drvn insltn tester , discharge rod , battery , power contactor , earth leakage relay , led lamp 220v , led lamp 240v , side box for bus bar , plug and socket complete , currenttransformer , push button switch , contactor main , allen bolt , aux contact , push switch , pilot relay , auto led lamp , contactor pak 450u , slip ring , bolt , ammeter , isplator lead outgoing , oprtg coil , busbar terminal assembly , bus bar terminal connecting , control relay , no nc electrical switch
Tender For supply of electrical items c c -contactor , head light , contactor pwr 525 415v , fixed contact , moving contact assembly , pilot relay , bush insulator for throughgoing incoming , ammeter , kit contct , 25 amp contactor unit 110v , currenttransformer , relay cntrl , pilot relay 12 v dc , fuse crtrg , push switch , connector , socket insulator with pin set
Tender For supply of electrical items c c -ht hrc fuses , insulated bus bar , earth bus bar , basic unit , series rector dry type magnetica , bus bar support insulator , cubical carrier assembly