Get complete information related to latest Porcelain Insulator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Porcelain Insulator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Porcelain Insulator Tenders.
Tender For supply of xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1),pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694,pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694,pvc insulated copper cable single and multi - core circular sheathed cable with flexible conductor (v2) as per is 694
Tender For corrigendum : supply of pvc insulated unsheathed cable with flexible conductor as per is 694 (q2) , pvc flat cable, aluminium conductor with pvc insulation and sheath as per is 694 (q3) , fixed capacitors (fixed capacitor for single phase ac electric fan) as per is 1709:1984 (q3) , piano type non modular domestic fan regulator as per is 11037 (q3) , non - modular piano type domestic electrical switches as per is 3854 (q3) , xlpe cable for working voltages up to and including 1.1 kv as per is 7098 (part 1) (q2) , elecric bells and accessories as per is 2268 (q3)
Tender For supply of 11kv, 3core, 300sqmm xlpe insulation armoured ug cable (sc rating of cable in ka-28.3ka and sc rating of armour in ka-15ka) as per tpcodl specification:eng- hv-20062.
Tender For providing, fixing and replacement of damaged primary side and secondary side porcelaininsulator changing of 500 kva, 3.3 kv/440 volt of power transformer at adarshnagar colony lajkura ocp, ibva.
Tender For supply of 16 sq mm x 4 core copper armared cable and cable pwr arm,cu,,3.5c,25sq.mm,90 a - 3126696, 200.000, cable power armoured,conductor material:copper,xlpe insulation ,no of cores:3.5c,size:25 sqmm,voltage:1100v ac,make-polycab/rr/finolex with drum
Tender For corrigendum : supply of c73340415174 supply of high static pressure ductable ac unit capacity 8point5 tr having one indoor and one out door unit consisting of scroll compressor refer annexure iii , 100000000001 supply of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac units 8point5 tr refer annexure iii , 100000000002 providing cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure iii , 100000000003 providing of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure iii , 100000000004 supply of site fabricated gi sheet metal ducts of 22 guage birmingham gauge 0point8 mm and zinc coating not less than refer annexure iii , 100000000005 supply of thermal insulation for supply air ducts with 19 mm class o thick self adhesive closed cell elastomeric refer annexure iii , 100000000006 supply of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam refer annexure iii , 100000000007 supply of volume control dampers vcd for ducts made of gi sheet of thickness not less than 18 g refer annexure iii , 100000000008 supplying of xlpe insulated, pvc sheathed, armoured, copper conductor 1point1 kv grade lt cable of size 4 core - 6 sqmm refer annexure iii , 100000000009 supply of xlpe insulated, pvc sheathe, copper conductor, , 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure iii , 100000000010 supply of 300 mm width x 50 mm depth x 1point6 mm thickness perforated hot dipped galvanised iron cable tray with cover refer annexure iii , 100000000011 supply of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure iii , 100000000012 installation testing and commissioning of high static pressure ductable ac unit ) /bid number : gem/2025/b/6778840 * /dated: 13-10-2025 & & / bid document 1 / 20 & & ' ' /item category capacity 8point5 tr refer annexure iv , 100000000013 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000014 laying of cpvc sdr11 pipes 32 mm with 9 mm thick tube type nitrile rubber insulation refer annexure iv , 100000000015 laying of cpvc sdr11 pipes 25 mm with 9 mm thick tube type nitrile rubber insulation refer annexure iv , 100000000016 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 22 guage refer annexure iv , 100000000017 fixing thermal insulation for supply air ducts with 19 mm refer annexure iv , 100000000018 fixing acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam refer annexure iv , 100000000019 erection testing and commissioning of volume control dampers vcd for ducts made of gi sheet refer annexure iv , 100000000020 laying of xlpe insulated,pvc sheathed, armoured,copper conductor,1point1 kv grade lt cable of size 4 core - 6 sqmm refer annexure iv , 100000000021 laying of xlpe insulated, pvc sheathe, copper conductor 1point1 kv grade lt cable of size 4 core - 2point5 sqmm refer annexure iv , 100000000022 installation of 300 mm width x 50 mm depth x 1point6 mm thickness perforated hot dipped galvanised iron cable tray with cover refer annexure iv , 100000000023 installation of 150 mm width x 50 mm depth x 1point6 mm thickness of perforated hot dipped galvanised iron cable tray refer annexure iv , 100000000024 dismantling and shifting of existing ductable indoor and outdoor 23 x8point5 tr outdoors are installed at roof tops of first to third floor refer annexure iv , 100000000025 dismantling and installation of existing false ceiling approx 800 sqfeet for installation of ductable split ac above false ceiling with all fitting same as before refer annexure iv