Get complete information related to latest Post Insulator Clamp Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Post Insulator Clamp Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Post Insulator Clamp Tenders.
Tender For tender for supply of equipment / material, design, erection, testing, commissioning for providing s.o.p. to newly constructed residential building at nift campus chebb at kangra under esd no. i hpsebl, kangra. - (a) material/erection of 11/0.4kv,250 kva s/stn., prov.distribution transformer (ordinary), 11/0.4 kv, 250 kva, prov.steel tubular poles (9 m, working load > 200 kgf/m ), prov.x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for incomer line, prov.ms angle iron (50x50x6 mm), length: (2800 mm) x1 nos for las, prov.x-arm: [channel iron (75x40x6 mm), length : (2800 mm x 4 nos] for supporting do fuse unit & go switch, prov.x-arm: [channel iron (100x50x5 mm), length : 2800 mm x 2 nos] for transformer bed, prov.x-arm [channel iron (100x50x5 mm), length : (460 mm) x 2 nos for supporting main channel of transformer], prov.ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov.ms angle iron (35x35x6 mm), length : (460 ) x 2 nos, prov.ms angle iron (50x50x6 mm), length : (950 mm) x 2 nos for bed knee bracing, prov.ms angle iron (50x50x6 mm), length : (2800 mm) x 2 nos, prov.ms angle iron (50x50x6 mm), length : (450 mm) x 1 nos, prov.go switch handle supporting: [channel iron (75x40x6 mm), length : 460 mm, prov.d.o fuse unit, prov.surge arrester, 9 kv station class (porcelain type), prov.discs insulator sets (comprising 1 no. disc: ^^(porcelain, bs, 12kv, 90 kn) including dead end clamps etc.), prov.pipe earthing set, lt distribution panel box with mccb(630a, 50 ka, 3p,1 no) and mccb(250 a, 36ka, 3p, 3 no.), prov.half clamp (m.s. flat 50x6 mm), prov.full clamps (m.s. flat 50x6 mm), prov.nuts and bolts of various sizes (galvanised / coated) [preferably 16 mm or more (with flat and spring washers)], aluminium thimble, copper thimble 200 amp, danger plate, prov.barbed wire, prov.energy meter (3-phase,4-wire)dlms compliant 400/5a ct type, prov. aluminium paint., prov.aaac 7/3.15mm conductor for earthing, erection charges complete in all respect, transportation charges complete in all respect, (b)material/erection of 11 kv ht line, prov aaac 7/3.15mm conductor (50mm ) {includes cutting and wastage}, prov. steel tubular poles (9 m, working load > 200 kgf/m ), prov.m.s. c.i.x-arm (1500x100x50x5 mm), long for single pole, prov.m.s a.i x-arm (1800x50x50x6 mm), long for single pole, prov m.s a.i x-arm (50x50x6 mm), length (2x750) mm long for single pole, prov m.s a.i x-arm (50x50x6 mm),length (2x600) mm long for single pole, prov.m.s c. i cross arm (75x40x5 mm), length (2400) mm for g.o switch & d.o fuses, prov.belt set - ms a.i 50x50x6, length [2400 mm x 2 no.] for double pole, prov.x-bracing set - ms a.i 50x50x6, length [2700 mm x 2 no.]for double pole, prov 11 kv pin insulators (porcelain, 12 kv, 10 kn), prov disc insulator ,1 no disc (12 kv, 90 kn) including dead end clamps etc., prov ht earthing set complete, prov double continous earth wire (gi, 8 swg) @ 0.102 kg/m, prov danger plate (250x200x1.6 mm), prov nuts and bolts of various sizeswith flat and spring washers, prov barbed wire, prov aluminium paint, prov.full clamps (m.s. flat 50x6 mm), prov.xerox for chebb s/stn for scada, prov.d.o fuse unit, erection charges of 9 mtr st pole complete in all respect, erection charges of stay set complete in all respect, erection charges of coil earthing complete in all respect, erection charges of g.o. switch complete in all respect, erection charges of sagging aaac 7/3.15mm conductor, sagging of continous earth wire (gi, 8swg) @ 0.102 kg/m complete in all respect, transportation charges complete in all respect, commissioning of a 250 kva dtr plinth and fencing, earth work in excavation by mechanical means (hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kinds o