Web Analytics Made Easy - StatCounter

Potentiostat Tenders

Get complete information related to latest Potentiostat Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Potentiostat Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Potentiostat Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government/Public Sector

CTN :43015104 Due date: 30 Dec, 202530 Dec, 2025 NA
Tender For corrigendum : supply of electrochemical workstation with bi-potentiostat/ galvanostat with corrosion, impedance and electrod

CTN :43207717 Due date: 06 Jan, 202606 Jan, 2026 2.36 Lacs
Tender For providing of custom bid for services - onsite annual maintenance contract of 2 nos potentiostat pgstat 302n serial no aut 85458/msb7203 and serial no aut 83697/msb7126 make metrohm for 2 years

CTN :43180866 Due date: 25 Dec, 202525 Dec, 2025 NA
Tender For supply of the following galvanostat/potentiostat consumables- glassy carbon ,electrode ,ag/agcl reference electrode ,platinum wire electrode ,polishing kit, sample holder ,electrochemical cell ,crocodile clip holder ,electrode

CTN :43176105 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For electrochemical workstation with potentiostat -(1 no.) in anrf pair network research project, sri venkateswara university, tirupati

CTN :42676806 Due date: 26 Dec, 202526 Dec, 2025 NA
Tender For corrigendum : fixing rate contract towards the supply of laboratory consumables to health institutions in ut of puducherry - before quoting bidders were requested to check the schedule of requirement in the notice inviting tender for supply units and estimated annual requirement. the selected bidder shall supply the items as per the supply units mentioned in the nit. note: for all the items samples should be submitted. without sample quotation will be rejected., antigen retrieval buffer, aqueous phenol 5%, biebrich scarlet, cryogel, hiv 1&2 antibody elisa 4th generation, luxol fast blue, methyl green, monoclonal antibody p63, monoclonal antibody - glut - 1, monoclonal antibody - eber, monoclonal antibody - p16 ink 4a, monoclonal antibody - pax - 5, monoclonal antibody - psa, monoclonal antibody p53, monoclonal antibody tle, non specific esterase cytochemical staining kit, oil red o, peanut oil, proteinase - k - for paraffin block tissue, pyronin- y, rubeanic acid, smiths reagent, sodium polyanethol sulphonate (sps), sudan red 3, toluidine blue 1 % solution, weigerts hematoxylin, c3c complement polyclonal immunofluorescense anit body - fitc conjugated, iga - immunoglobulin a polyclonal immunofluorescense anit body - fitc conjugate, igg - immunoglobulin g polyclonal immunofluorescense anti body - fitc conjugated ., igm - immunoglobulin m polyclonal immunogluorescense anit body- fitc conjugated, kappa polyclonal immunofluorescense anti body - fitc conjugated, lambda polyclonal immunofluorescense anti body - fitc conjugated, michels transport medium, pbs phosphate - buffered salline (10x) ph 7.4 , rnase - free, tissue freezing medium for frozen section (cryostat), blood bag tube stripper, blood collection monitor (automatic), di electric bio-sealer for blood bag, disposable bilical calibration tips for bilicheck, electrical autoclave for blood bank, flexible probe with eye 13cm stainless steel, grossing knife stainless steel 200mm, l. mould bronze (large), l. mould bronze (medium), pippette bellowa, spirit lamp (170 ml), thermograph round chart paper, transparent acrylic museum jar/cylinder (h25xb16.5xw14cm), transparent acrylic museum jar/cylinder (h25xb25xw12cm), actidione, adonitol, agaraose low eeo, for molecular biology, alpha - naphthylamine solution, andrades indicator, anti serum factor 2 salmonella paratyphi a (ah), anti serum salmonella typhi (factor 9), anti serum v.cholerae hikojima, anti serum v.cholerae inaba, anti serum v.cholerae o139, anti serum v.cholerae ogawa, antibiotic disc ceftazidime/avibactum, antibiotic disc ceptazidime 30 mcg, antibiotic disc ceptazidime / clavulanic acid 30/10mcg, antibiotic disc co-trimoxazole 25 mcg, antibiotic disc netromycin, antibiotic disc pefloxacin 30 mcg, antibiotic zone scale, anti-hbs elisa (96 tests, ivd, qualitative and quantitative detection of total antibodies to hepatitis b surface antigen (anti-hbs) in human serum or plasma, ce marking european directive 98/79/ce on in vitro diagnostic medical devices or equivalent), antimicrobial susceptibility discs - cefoperazone + sulbactam - 75/10 mcg, antimicrobial susceptibility discs - novobiocin 5 mcg, antimicrobial susceptibility discs - cephalexin 30 mcg, antimicrobial susceptibility discs - linezolid - 30 mcg, antimicrobial susceptibility discs - cefixime 5 mcg, antimicrobial susceptibility discs - gatifloxacin 5 mcg, antimicrobial susceptibility discs - novobiocin 10 mcg, antimicrobial susceptibility discs - piperacillin sulbactum-100/10 mcg, antimicrobial susceptibility discs- amoxycillin 10mcg, antimicrobial susceptibility discs- ceftazidime 30mcg, antisera salmonella paratyphi b, antisera vibrio cholera 0139 bengal, antisera vibrio cholera polyvalent, antiserum shigella boydii, antiserum shigella dysenteriae, antiserum shigella flexneri, antiserum shigella polyvalent antisera, antiserum shigella sonnei, auramine chemical formula-c17h22cln3, mol wt: 303.84, automated dna/ rna virus extraction (from vtm, blood, serum,

CTN :42901834 Due date: 24 Dec, 202524 Dec, 2025 NA
Tender For corrigendum : purchase of equipments - purchase of equipment, 1. configuration design an 8-channel battery analyzer and its accessories 2. power 425 w3. voltage measuring range: 25 mv to 5 v, discharge minimum voltage: 0v or better, accuracy: 0.05% of fs4. current range: 0.5 ma to 6 a, accuracy: 0.05% of fs or better 5. power per channel output power: 30w, stability; +/- 0.1% of fs or better6. time rise time: 1ms (0~full range)7. frequency 10hz8. charge mode of operation: cc, cv, cccv, cp end conditions: voltage, current, relative time, capacity.9. discharge mode of operation: cc, cv, cp, cr, end conditions: voltage, current, test time, capacity, energy.10. pulse mode charge: cp mode, cc mode, discharge: cc mode, cp mode, min pulse width: 500ms, automated switch: automated switch from charge to discharge for each pulse end condition: voltage, relative time11. dcir support for the calculation of the point of the dcir12. cycle cycles: 1 65500 or better, steps: 250 or better, nested function: max three levels of loops13. protective function software, power-down data protection, user-defined safety (upper and lower) tolerance of current, voltage, and delay time14. channel features independent pairs of closed loops for the constant current source and constant-voltage source15. test reports and curves for analysis different types of curves created by software based on user definition. (voltage-time curve, current-time curve, capacity-voltage curve, loops times charge/discharge capacity curve, loops times charge/ discharge efficiency curve, etc.), data reports created by the software. comparison of the performance of the batteries tested in channels, both visually and statistically16. channels independent control17. ac input ac 220v 10% / 50hz 18. voltage and current testing sample 4 wire connecting 19. noise 85db20. data management mysql database21. communication means tcp/ip protocol22. data output excel, txt23. communication interface ethernet port24. number of channels per cabinet 825. accessories: 1. bi-potentiostat: electrochemical workstation or moduletechniques the system should be capable of running the rde / rrde technique simultaneously cyclic voltammetry (cv) with simulation/fitting programs linear sweep voltammetry (lsv) with stripping bulk electrolysis with coulometry (be) differential pulse voltammetry (dpv) with stripping normal pulse voltammetry (npv) with stripping tafel plot (tafel), potentiodynamic deactivation, pitting corrosion, corrosion rate, linear polarization, corrosion current, etc. multi-current steps (istep) amperometric i-t curve (i-t) lifetime testing open circuit potential time (ocpt) chrono amperometry (ca) chrono coulometry (cc) chronopotentiometry with current ramp (cpcr) potentiometric stripping analysis (psa) auxiliary signal measurement channel ir compensation external potential input galvanostatic charge discharge single/multiple cycle -chrono potentiometry (cp) with potential limits, polarity by potential or time, no. of cycles etc. voltage vs current density curves single or multiple potential steps with charge limits, single or multiple current steps, mixed voltage/current control using macro. i-v measurements, i max, pmax, fill factor, etc.impedance ac impedance (imp) 10 hz to 3mhz impedance time (impt) (mott-schottky) impedance potential (impe) impedance simulator with fitting open circuit potential time (ocpt)hardware specification of bi-potentiostat workstation/ module: potentiostat / galvanostat module, 2- or 3- or 4-electrode configuration maximum potential: 10v, maximum current: 250 ma peak or better and 2 amps with +/-25 volts for higher current measurement. compliance voltage: > 13v or better, potentiostat rise time: 300 ns or better galvanostat applied current range: 3na to +/- 100ma or better and upto 2 amps applied current accuracy: 20 pa or better input bias current: 1 pa or better cv and lsv scan rate: 0.000001 to 10,000 v/s. ca and cc pulse width: 0.0001 to 1000 sec imp freque
 Loading, Please wait...

Connect us via What's Up