Tender For comprehensive operation & maintenance of wds & esr & network with all electrical & mechanical equipments & instruments with civil works at tp-10 wds in guda area for two years.-, centrifugal pump motor set, , ci d/f sluice valve, , butterfly valve, , reflux valve, , dual plate valve, , s.s. expansion below, , single girder eot crane, , monorail with electrically operated chain hoist, , dewatering pump, , portable dewatering pump, , chlorination system, , digital chlorine detector, , pressure measuring system, , pressure transmitter, , level measuring system, , float and board type, , level indicator, , level measuring system, , ultrasonic type level transmitter, , float type level switches 12" large led display, , online amperomatric type frc cum ph analyzer, , full bore, , electromagnetic flow meter, , flow meter, , plc based control system, , all instrument, cable and accessories work, , 11 kv switch yard/ 2 pole structure, , ht indoor switch gear panel, , distribution transformer, , low voltage panel board, , powerdistributionboard, , lighting distributionboard, , all low voltage cable, , all cable end termination connection, , all cable tray, , all earning and internal wiring, , all internal and external light fixtures and lighting, , esr, , ussr, , all piping work, , all road work, , all paver work and kerbing work, , all admin building work, , compound wall and gate, ,
Tender For corrigendum : manufacturing, procurement of materials, testing at manufacturers works, inspection by tpia, packing, supply of trolley hoists and chain hoists and classified area local powerdistributionboard, power junction box and socket outlet
Tender For corrigendum : supply of main switchboard msb-1 with control section distributionsection and complete power management system pms facility as per tsp section ii para 1.1 2.1 , main switchboard msb-2 with control section distribution section and complete power management system pms facility as per tsp section ii para 1.1 2.1 3.1 , switchboard for emergency diesel alternator 135kw consisting of control section and feeder section as per tsp section ii para 1.1 2.1 3.1 , powerdistributionboards pdbs 415vac mccb type 3 ph in 3 ph out 12 output with auto changeover facility as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 415vac mccb type 3 ph in 3 ph out 4 output as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 415vac mccb type 3 ph in 3 ph out 10 output as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 415vac mccb type 3 ph in 3 ph out 8 output as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 230vac mcb type 3 ph in 3 ph out 8 output with manual changeover switch as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 230vac mcb type 3 ph in 1 ph out 12 output as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 24vdc mcb type 8 output as per tsp section ii para 2.3 3.3 , powerdistributionboards pdbs 24vdc mcb type 8 output with interlock circuit as per tsp section ii para 2.3 3.3 , lighting distributionboards ldbs 230vac mcb type 1 ph in 1 ph out 8 output as per tsp section ii para 2.3 3.3 , shore supply connection box sscb as per tsp para 2.4 3.4 , external supply panel of 800a as per tsp para 2.5 3.5 , rectifier cum battery chargers with batteries 60a 1.5kw24vdc as per tsp para 2.6 3.6 , rectifier cum battery chargers with batteries 130a 3kw24vdc as per tsp para 2.6 3.6 , on board spares separate list for msb, esb pdbs esp scb , documentation separate list for msb esb pdbs esp scb , installation material as per tsp separate list for msb esb pdbs esp scb , services of engineers installation and stw , services of engineers for hats , services of engineers for sats , training , monthlywarranty extension charges for 12 months beyond december 2026 , represervation of charges 06 months for msbesb apms rectifier cum battery charger if required , extra man-days for 1st year , extra man- days for 2nd year
Tender For upgradation augmentation of shot blasting equipment and shot blasting room including replacement of three motor driven screw lp air compressor for upgradation augmentation of production shop floor (ab and ac bay) at ins eksila - upgradation/ augmentation of shot blasting equipment and shot blasting room including replacement lp air compressor as indicated in part-ii of rfp consists of the following:-, dismantling and degutting of lp air compressors along with all associated equipments and shifting work as specifiied in para 1(1.1)(a) part ii of rfp., lp air compressor, lp air compressor as specifiied in para 3 (3.1) part ii of rfp., dryer unit as specifiied in para 3 (3.1) part ii of rfp., air receiver tank (2000 liters) as specifiied in para 3 (3.1) part ii of rfp., air filter as specifiied in para 3 (3.1) part ii of rfp., acoustic canopy as specifiied in para 4 (4.1)(a) & (b) part ii of rfp., electric powerdistributionboard/ control panel as specifiied in para 4 (4.1)(d) part ii of rfp., dismantling and degutting of shot blasting system along with all associated equipments and shifting work as specifiied in para 1.2 of part ii of rfp., shot blasting system, protection liner & rubber lining as specifiied in para 3(3.2) part ii of rfp., recovery unit as specifiied in para 3(3.2) part ii of rfp., dust collector & exhaust system as specifiied in para 3(3.2) part ii of rfp., shot blasting unit as specifiied in para 3(3.2) part ii of rfp., all other items associated with main eqipment which are mentioned in part ii of rfp [ex para 6(a) & 6(b) etc] part ii of rfp)., civil work for (refers to para 8 of part ii of rfp)., standard accessories (refers to para 9 of part ii of rfp), two years operation & maintenance spares (refers to para 10 of part ii of rfp), special maintenance tools and test equipment (refers to para 11 of part ii of rfp), technical literature / certificates / documentation (refers to para 13 of part ii of rfp), acceptance, testing, trials and commissioning charges (refers to para 14 of part ii of rfp), training (refers to para 16 of part ii of rfp), any other item such as transportation, insurance, freight, packing etc, notes:1. cost of item listed at sl 1 to 12 and 13 (if applicable) are to be quoted in the respective rows of the price bid sheet. 2. bidder not permitted to include cost of items listed at sl 6 to 13 with sl 1 to 5 as lumpsum amount 3. bidder required to mandatorily quote for sl 1 to 5 and 12 failing which bid shall be treated as non bonafide and liable for rejection.4. bidders are mandatorily to quote gst/ taxes as applicable against each serials, falling which bid shall be treated as non bonafide and liable for rejection.