Tender For supply of sitc of 5 megapixel camera , supply of workstation , supply of rack camera server , sitc of 8 port poe l2 switch , base software for anpr and driver face capture , supply of vms and digital video surveillance control software for camera live view and recoding per camera license. , supply of automatic number plate reader per camera license. , supply of face capture per camera license. , surge protection device , supply and laying of cat-6 stp data cable , supply and laying of 3 core 2.5 sq mm power cable , supply and laying of optic fibre communication outdoor cable , supply of 12 port light guide interconnect unit liu , sitc of 2 kva online ups with smf batteries , sitc of equipment rack 40 u or 42 u , supply and laying of 50 mm diameter hdpe pipe , supply and installation of 3 inch diameter up to 5 mtrs. height gi pole , earthing with copper plates as per specifications. , excavation in soft or hard soil with the required depth up to 75 cms and backfilling , road cutting with the required depth up to 40 cms and backfilling , installation, testing and commissioning of the complete system.
Tender For supply and installation of necessary equipment for updating the fire and safety system installed in regional office, chandigarh - diesel engine driven main fire pump supplying, installation, testing and commissioning of diesel engine driven main fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (diesel driven pump) horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to is 1520. suitable hp, 1500 rpm water cooled with radiator, diesel engine conforming to relevant is standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required. m.s fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required. suitable cement concrete foundation duly plastered and with anti vibration pads.(for 1620 lpm at 56 m head) note- the head of the pump is selected in a manner so as to give a minimum 3.5 kgf/cm2 pressure at the highest farthest point., control panelfabrication, supply, installation testing & commissioning of electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick crca sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, inter connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for main fire pump, pressurisation pump & diesel pump set complete as per cpwd specification with following in coming and outgoings, suitable for operation on 415v, 3 phase, 50hz ac supply with enclosure protection class ip 42 as required :incoming250a, 50ka 4 pole mccb, ics=100% icu rating ,digital voltmeter 0-500v with selector switch digital ammeter (0-250 a) with selector switch & cts etc. led type ryb phase indicating lamps, on, off, trip indicating lamps, set of copper bus bar 300a.outgoing( note : all outgoing feeders for pumps should have digital ammeter with selector switches, and led type on, off, trip indicating lamps)main fire pump125 a, 50ka tpn mccb, ics=100% icu, with fully automatic star/delta starter suitable for 60 hp pump with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.jockey pump63 a, 50ka tpn mccb, ics=100% icu, with suitable hp fully automatic star/delta starter with overload protection, current sensing type single phase preventer complete with all accessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/off operation.diesel engine controlcontrol for diesel engine comprising -automatic/manual selector switch & 3 attempts starting device, timers and relays as required, push buttons, start/stop in manual mode indicating lamp for high/ low lub. oil pressure, high water temp and engine on indication, battery charger suitable for 12v/24 v dc with boost and trickle selector switch, 0-30 v dc volt meter, and 0- 20 a dc ammeter. all standard relays and accessories for automatic operation of diesel enginesystem controllerdesigning, supply, installation, testing and commissioning of system controller to control operation of main electric fire pump, diesel pump, pressurization pump, terrace pump in sequence as per specification consisting of relays, timers. sensors, annunciat
Tender For various wqms activity 2024-25 (water quality monitoring survey). supply of laboratory equipement and chemical etc. and all other works contingent thereto. - bact. incubator:- nsw, ambassdor, optics technology, impact size 18x24x18.precise sterilization, incubating and drying in one unit. better mineral/ glass wool blanker insulation keeps the surface of the instrument from being burnt.silent hot air blower unique design of air circulation for uniform air movement. unique design of ventilation keeps the surface of the instruments from veing burnt. polish 304 grade s. steel interior corrosion resistant long life operation having adjustable shelves to make more space for different height. kanthal a-1, super quality coil shaped heaters duly embedded / wounded on the sides and bottom for better accuracy . full feature with touch screen controller temperature controller. a. hmi display with feather screen touch digital temperature controller b. continuous display of temperature, time, day and date door open alarm c. password protected operations. d. data transfer port: usb port technical specification:- temperature range : ambient to 70 c temperature stability : 0.5 c control panel : with mains and load indicator, mcb alarm , material : gi/ms with powder coated, inner : stainless steel 304, digital setting : 0.1 c digital resolution : 0.1 c safety function : temp. over shoot high and low temp. alarm 5 d c , mcb provided insulation: mineral wool front door : mineral wool insulated door with glass window. hardware:- lock and handle material zinc, base finish: spc, handle finish: black pc b3with key. hinges material zinc, pin material : ss 304 grade, finish stpc, opening angle : 180 deg power consumption: 220/230v ac supply 10% hz duty cycle : continuous, air conditioner 1.5 ton split, autoclave:- nsw,ambassdor, impact digital cap:- 78 liters heater:- 04kw size:- 400x600mm outer ss sheet chamber inner s.s. 304 unique desingn of radial locking for minimum steam loss, assure accurate steam generation / sterilization. s. steel 304 grade argon welded cylindrical inner tank / vessel having s. steel tabular immersion heater for steam generation. lid is made of thick mild steel plain lined with s. steel sheet for double protection optional : all s. steel thick lined lid/ s.s. ring 304 grade (all outer s. s. outer body-304 grade steel on customer request). fitted with painted mild steel ring and radial locking duly chrome plated. paddle lifting device is also provided. lid is having built in safety valve, release valve pressure gauge, water level / indicator. supplied with s. steel cylindrical basket. pressure range is adjustable from 05 to 20 psi 3 psi or better inner and outer wall both made of stainless steel. gasket is made from imported silicon rubber. fitted with microprocessor based fully automatic fuzzy logic control system with timer buzzer (auto time control). the unit is also fitted with low-water level cut-off as a standard feature. fitted with automatic purging and exhaust valve, beakers 1000ml (borosil), bottle brush, brown paper sheet, colour standard (100ml), cotton (500gm), dessicator (big size), borosil, durum tubes (100 in each pkt.), evaparating dish (12 nos) make borosil 3180072 evaporating, flat bottom with pour out dish ( approx o.d x height : 80x45 mm), macconkey broth (hi-media) 500gm, refrigrator temperature 0 to 20 c vertical shelves, atleast 6-shelves for storage of sample, inbuilt temperature controller, castor wheels for easy mobility, heavy duty wheels, toughend glass refrigrator with temp controll visi cooler with temperature indicator with nabl calibration 550 litres manual defrost system complete fridge dimensions - 64.00 x 72.00 x 205.00 cms reciprocating compressor 12 months warranty storage, silica gel grannules , 500 gm qualigens, spactula (steel), test tube basket, test tube stands (alumimium), test tubes (15x150mm), test tubes (18x150mm), turbidity standard (100ml)
Tender For corrigendum : e-bid for rate contract cum supply and empanelment of surgical and suture items - anti a blood grouping serum ip(anti a monoclonal serum) [225], anti b blood grouping serum ip(anti b mono clonal serum) [226], anti d(rh) blood grouping serum ip/anti d blood grouping serum ip [227], vdrl antigen (with +ve and -ve control) / rpr slide kit :- specification for rpr _rapid plasma regain) slide test for detection of regain antibodies in syphilis1. rapid plasma reagin test kit having non- treponemal cardiolipin antigen coated carbon particles used in the detection of regain antibodies in serum / plasma of suspected cases of syphilis by the flocculation reaction.2. the kit should be meant for qualitative and semi quantitative detection of regain antiboidies against the non-treponemal cardiolipin antigen.3. sensitivity & specificity should be 95% or more.4. positive & negative control serum should be provided with the kit for at least 10% of the tests in each kit.5. the kit should have shelf life of minimum 12 months or more at the time of delivery of consignment. the kit should be stored at 2 c - 8 c.6. adequate literature detailing the principle, components, methodologies, validity criteria. bio-safety, performance characteristics, storage conditions, limitation of assay, manufacture and expiry dates and methods of disposal should be provided with each kit.7. the test should be free from possible interferences with potentially cross reactive sera.8. all the test kits should be provided with necessary / required disposable accessories in sufficient quantity.9. the imported kit should have approval of the statutory authority in its country of origin . the imported kits should have been registered and licensed in india by the cdsco. (central drugs standard control organization), double blood bags with sagm (350ml)general specifications annexure- xvi and specification in annexure-xxiii, laproscopic knotless pga -pcl bidirectional taper point surgical suture self fixation device with autolock mechanism made up of pga -pcl bidirectional taper point 17 mm & 32cm, curved cutter stapler 40 mm linear cutter simultaneous cutting and stapling, aortic punch 4.5 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue, conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, aortic punch 3.6 length betwwen 6 to 7 midlength diamond edge sharp, dual cut edge for clean precise removal of aortic tissue,conical tip or round / eliptical tip for easy insertation by straight or button hole tech, should have long and short handle confirguaration, sterile packing, biopsy gun with compatible co-axial needle 14g x 11cm to 20cm programmable automatic should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved., programmable automatic biopsy gun with compatible co-axial needle size 18gx11cm or above should have 20mm sample notch and thin wall cannula for larger core and echogenic making on both stylet tip and cannula for improved visibility during procedure. should have three programmable firing mode-automatic mode, delay mode and zero throw mode. should have two firing btton on surface of the gun, size 12g, 14g, 16g, 18g, 20g with length 11cm, 15cm, 20cm. should come with compatible coaxial packed with biopsy gun. usfda approved. (size 18gx11cm or above), programmable automatic biopsy gun with compatible co-axial needle size 18gx15cm or above should have 20mm sample notch and thin wall cannula for larger core and