Tender For supply of static inverter 25kva for rmpu (underslung) for lhb hybrid sg ac coaches with control cable length pp&npp=18mts each, as per drawing: rdso/pe/spec/ac/0024 rev-" 0" 2001 am-2. , packing instruction: electrical panels to be protected with transparent bio degradable polythene bag/sheets thickness of 0.1 mm or an antistatic bag of 350 to 400 gauge (100 micron approx.) on all sides of panel & panel shall be packed in transport w orthy wooden cage. bottom frame to be made of wooden planks 20mm thick & should h ave support of at least 3 wooden batons of size 100x100mm of suitable length to facili tate lifting by fork lifter & secure properly with suitable packing to avoid in-transit d amage. each panel to be packed in transport worthy wooden cage of suitable dimensio ns made out of wooden strip of 20x100 mm size. gap between each strips should not be more then 100mm.a list should be pasted on each wooden cage showing order no, pl no , description, drg /spec. no, qty, firm' name & address, consignee name, date of dispatch, top bottom arrow mark etc. [ warranty period: 30 months after the date of delivery ]
Tender For supply, delivery, installation of 20 hp submersible pump motor set and electrical controlpanel with allied works in newly constructed replaced well at dumping ground dtw based pumping station (p.h no-03) of rajarhat zone-ii
Tender For a/r & m/o lwss from juni khad to uppper pandoh & its adjoining villages in gp pandoh, sayogi, jagar & dhar tehsil sadar distt. mandi (hp). (sh:- repair/overhauling of controlpanel and ocb and providing |& fixing of electrical equipments in pump house ist stage and 2nd stage).
Tender For corrigendum : e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. controlpanel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. controlpanel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not
Tender For providing of customized amc/cmc for pre-owned products - electrical; servicing of 3 section ht panel and its relays with control wiring; annual maintenance contract (amc); six-monthly; no
Tender For corrigendum : supply of machine guarding - box 600x400x300 , machine guarding , guard for z axis , x axis rear guide way guard , cnc control post , electrical panel transformer , terminal box
Tender For construction of electrical controlpanel room and plinth & chain link fencing for transformer in ttd kalyanamandapam nandyal, nandyal district
Tender For supply installation testing and commissionning of electolytic water condition system at carriage workshop, lallaguda compr ising of : electrolytic water conditioner unit with appropriate capacity and specifications with a suitable low ?voltage power source .controlpanel for monitoring and adjusting the electrolysis process prefiltration system (02 nos) to remove turbidity and impurities from raw water before treatment necessary piping ,fittings, and accessories for integration with the existing water supply system .electrical components an d cabling as per system requirements. technical specification give in annexure . drawing copy with enclosed . [ warranty period: 30 mont hs after the date of delivery ]