Web Analytics Made Easy - StatCounter

Power Factor Correction Panel Repair Tenders

Get complete information related to latest Power Factor Correction Panel Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Factor Correction Panel Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Factor Correction Panel Repair Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :41661596 Due date: 22 Sep, 202522 Sep, 2025 70.55 Crore
Tender For supply of 11kv indoor vcb 10 panel set with spares and individual panels

Central Government/Public Sector

CTN :41669620 Due date: 08 Sep, 202508 Sep, 2025 NA
Tender For notice for request for quotation (rfq) for supply of spares for lv panel at kempegowda international airport, bengaluru

Central Government/Public Sector

CTN :41359296 Due date: 08 Sep, 202508 Sep, 2025 NA
Tender For corrigendum : procurement of max panel abb spares for ntpc bongaigaon.

Central Government/Public Sector

CTN :41553340 Due date: 15 Sep, 202515 Sep, 2025 NA
Tender For corrigendum : supply of fanuc spares for cnc machines d d - , fan a90l 0001 0506 280 , fuse 3 point 2a a60l 0001 0290 lm32 , fuse 2 point 0a a60l 0001 0175 2 point 0a , fuse a60l 0001 0290 lm10c , fuse 200a a60l 0001 0362 200u , fuse hm5 point 0 a60l 0001 0359 , fuse 7 point 5a a60l 0001 0046 7 point 5r , cable a66l 4040 0032 , battery lr20 a98l 0031 0005 , battery a98l 0031 0025 , fan a90l 0001 0509 , fan a90l 0001 0511 , fan a90l 0001 0441 39 , machine operator s panel sub panel aa02b 0236 c232 , mdi unita02b 0303 c328 , i f module aif01aa03b 0819 c011 , digital input module aid16da03b 0819 c104 , dc out point mdl aor08g a03b 0819 c160 , p point c point board with ic dc output module aor1a03b 0819 c161 , high speed counter module act01a a03b 0819 c064 , led driver for 15 inch lcd a20b 2005 0362 , screw a6 sw2na 3x6s , lcd a61l 0001 0233 , cable a660 4042 t095 l250r0 , led driver cable for 15 inch lcd a660 4042 t102 l160r0 , handy machine operator s panel a02b 0259 c221 a , p point c point board with ic memory module a76l 0500 0022 , mdi unit milling ong horizontal 220x a02b 0303 c320 m , pcb a20b 2003 0860 , interface unit for handy machine operator a02b 0259 c220 , ac servo motor alpha is 50 3000hv 1 a06b 0276 b500 , ac servo motor alpha is 50 3000hv 2 a06b 0276 b200 , position detector i f unit 1 a02b 0303 c205 , dynamic brake module a06b 6079 h401 , power supply psmc 45hv a06b 6083 h245 , power supply alpha is 30hv a06b 6150 h030 , a1000i pulse coder a860 2000 t301 , pulse coder alpha a1000s 1000000pulse rev a860 0372 t001 , position detector i f unit 2 a02b 0236 c205 , i o module for operator s panel b2 a20b 2002 0521 , i o module for connector panel b1 a03b 0815 c001 , i o module for connector panel ea a03b 0815 c002 , i o module for connector panel eb a03b 0815 c003 , machine operator s panel sub panel b1 a02b 0236 c235 , key board mdi unit a02b 0281 c125 tbe , operators panel main panel b a02b 0236 c243 , cpu card pcb 32mb dram a20b 3300 0601 , power supply alpha ips 100hv a06b 6150 h100 , power failure back up module a06b 6091 h002 , lcd unita02b 0281 c072

Central Government/Public Sector

CTN :41175307 Due date: 30 Sep, 202530 Sep, 2025 NA
Tender For corrigendum : procurement of 05 nos. of panel hmi spares for process gas compressor turbine control systems sgt 400 turbine at bpb platform bns asset. -panel mount hmi for bcpa2 , panel mount hmi for bcpa2

Central Government/Public Sector

CTN :41655774 Due date: 15 Sep, 202515 Sep, 2025 NA
Tender For tender for supply of supply of abb make vha panel and breaker spares at nrl site on pac bid basis : : - for details refer item 01 in page no 02 to 05 of specfication document , for details refer item 02 in page no 02 to 05 of specfication document , for details refer item 03 in page no 02 to 05 of specfication document , for details refer item 04 in page no 02 to 05 of specfication document , for details refer item 05 in page no 02 to 05 of specfication document , for details refer item 06 in page no 02 to 05 of specfication document , for details refer item 07 in page no 02 to 05 of specfication document , for details refer item 08 in page no 02 to 05 of specfication document , for details refer item 09 in page no 02 to 05 of specfication document , for details refer item 10 in page no 02 to 05 of specfication document , for details refer item 11 in page no 02 to 05 of specfication document , for details refer item 12 in page no 02 to 05 of specfication document , for details refer item 13 in page no 02 to 05 of specfication document , for details refer item 14 in page no 02 to 05 of specfication document , for details refer item 15 in page no 02 to 05 of specfication document , for details refer item 16 in page no 02 to 05 of specfication document , for details refer item 17 in page no 02 to 05 of specfication document , for details refer item 18 in page no 02 to 05 of specfication document , for details refer item 19 in page no 02 to 05 of specfication document , for details refer item 20 in page no 02 to 05 of specfication document , for details refer item 21 in page no 02 to 05 of specfication document , for details refer item 22 in page no 02 to 05 of specfication document

Central Government/Public Sector

CTN :41650937 Due date: 10 Sep, 202510 Sep, 2025 NA
Tender For supply of supply, testing and installation and commissioning of spares of 11kv outgoing panel for gtg

Central Government/Public Sector

CTN :41303766 Due date: 04 Sep, 202504 Sep, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For corrigendum : supply of gas plant spares c c - da u13 panel , flashback arrestor for gas manifold , hose pipe , pressure gauge , bu13 panel , co2 s.s heater , co2 flexible hose pipe , srv safety relief valve , alarm system , ball valve , flexible hose pipe 1 mtr with customised connection , flexible hose 2 mtr with customised connection ) /bid number : gem/2025/b/6528118 * /dated: 02-08-2025 & & / bid document 1 / 17

CTN :41395950 Due date: 08 Sep, 202508 Sep, 2025 NA
Tender For corrigendum : tender for supply of electrical spares d dmatch subcategory gem bunch - pressure gauge 0-25 kg/cm2 , fuse 36a size 00 , hrc fuse16amps for 1.5kw , make ee/gec , hrc fuse 2a , make- ee/gec , hrc fuse 4a , make - ee/gec , hrc fuse 6a , make- ee/gec , hrc fuse 63a , make - ee/gec , indicating lamp 240v ac (red) , lamp holder with lens red , 10a dp dc mcb , 20a dp dc mcb , led indicating lamp 230v blue , 16a dp mcb , 25a dp mcb , 32a dp mcb , hrc fuse base & carrier , voltmeter 0-500v red mark at 415v , power factor meter 0.5-1-0.5 red mark at 0.8 , switch 16a 415v ac tp 2way with off , push button start green with 1no+1nc contactblock , hrc fuse link 4a , main & aux. contact kit for 44a bch make contactor , mcb-16a , dp , 24v dc , mcb-25a , dp , 24v dc , hbc fuse link 2a , ns2 , hbc fuse links ns 4w , hbc fuse links ns 16w , hrc fuse link , 16a , double wound control transformer 415/230v , 50va , aux. contact block for 25a contactor , 16a contactor with 240v ac coil , tp mccb i.th 25a o/l set 20a , 2 pole mcb 32a , power factor meter 0.5-1-0.5 red mark at 0.8 , annunciator window for flood alarm panel , contactor coil 44a make bch

CTN :41649676 Due date: 09 Sep, 202509 Sep, 2025 NA
Tender For procurement of spares for generator set 30 kva - 6240 004462 lamp filament indication lamp , 6625 002404 volt meter ac 0-300 , nd 6625 002405 ammeter ac amp meter , nd 6625 001489 meter elect frequency , nd 6625 003069 amp meter dc 0 30 amp , nd misc sk 9328 meter time hrs meter , 5930 000762 push button , nd ixb 2943 switch toggle , nd 5930 004262 switch rotary volt meter , 5930 001990 switch rotary ammp meter , 5930 000269 switch rotary 3 pole , nd ixb 2934 switch rotary main switch , ixb 3157 rectifir selenium , 5935 003452 connector free elec , 6150 000271 cable assy pe 10 mm wire , 6145 910260 sleeving insu sleeve plastic , 5325 000170 eyelet aluminium ilet , 5970 001939 slave insulation elect pvc , rp iyc 0839 insulation tape , 5950 005265 transformer vt volt adjuster , 6150 000272 cable assy 1 point 5 mm wire , 6150 00273 wire 14mm , 5945 001901 relay 24 vdgz pole changeover , mg 19 dynaf 7 00 216 08 cable tie , ixc kr 34 188 03 0 stop solonide , ixb 3053 151091 assy lamp c w cabin light , 6115 000740 panel lamp , ixc lvc 26250234 terminal main bty terminal , nd 5935 001795 socket elect 63 amp , 5920 000155 fuse holder 32a , nd 5920 001378 fuse holder backelite 125a , 6115 000492 rator gen 30kva silip ring , lv6 mt4 3110 001085 alternator bearing 6029 , nd 5977 000450 brush elect carbon , nd ixb 3198 timer transistorsed relay , 5950 005264 transformer current , ixb 3614 sleeve terminal flexible pipe , 50 55 13 angle for black out tail lamp , 646628 m1 oil seal hub , 9905 000283 red reflector , 2937004 brake shoe lining , 4710 000241 air pipe line assy , 2530 002526 pipe steel 11t x 16mm qd x 1000 mm long , nd ixc rh ydak 49000k assy main fan and drive , nd ixc kr aypak 995 716 speed adjuster complete with cable assy
 Loading, Please wait...

Connect us via What's Up