Web Analytics Made Easy - StatCounter

Power Fencing Tenders

Get complete information related to latest Power Fencing Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Fencing Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Fencing Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39393944 Due date: 10 Mar, 202510 Mar, 2025 2.29 Lacs
Tender For corrigendum : reinstallation of 3 line solar power fencing at nellikkunnu (1 km) area under vaniyampara forest station of peechi - vazhani wildlife sanctuary during 2024-25

State Government

CTN :39393980 Due date: 10 Mar, 202510 Mar, 2025 5.58 Lacs
Tender For corrigendum : reinstallation of 3 line solar power fencing at maniyankinar-kombungal (2.55 km) area under olakara forest station of peechi - vazhani wildlife sanctuary during 2024-25

State Government

CTN :39394113 Due date: 10 Mar, 202510 Mar, 2025 2.99 Lacs
Tender For corrigendum : installation of 3 line solar power fencing at adukkalappara-plakkode (1 km) area under vaniyampara forest station of peechi - vazhani wildlife sanctuary during 2024-25

State Government

CTN :39563115 Due date: 13 Mar, 202513 Mar, 2025 7.21 Lacs
Tender For supply,installation and commisioning of solar power fencing line from chapparam to 35th mile at varayal forest station of peria range during 2024-25

State Government

CTN :39563170 Due date: 13 Mar, 202513 Mar, 2025 7.21 Lacs
Tender For supply,installing and commisioning of solar power fencing line arounf mylattumala at varayal forest station of peria range during 2024-25

State Government

CTN :39452090 Due date: 08 Mar, 202508 Mar, 2025 4.06 Lacs
Tender For corrigendum : erecting and commissioning hanging solar power fencing at nazranikkad area baderi section of meppady range during 2024-25

Central Government/Public Sector

CTN :39545713 Due date: 31 Mar, 202531 Mar, 2025 2.41 Crore
Tender For special repairs of power fencing on existing perimeter wall of naval dockyard, visakhapatnam under ge (i) dm, visakhapatnam

CTN :39542182 Due date: 24 Mar, 202524 Mar, 2025 5
Tender For tender for supply of soil investigation - consultancy services for digital topographical land surveying 9.97 acres by using electronic total station , showing all existing details like bldgs , fencing boundary wall , road and existing drain with invert level , existing main sewage line , spot level at 5.00m into 5.00m , and contour interval at 0.20m. marking of bm and tbm as directed by ge , marking of proposed area drainage , sewage disposal , road path culvert , external water suppluy , external electric supply , compound wall fencing gate and rain water harvesting and submission of drawings in autocad format 10 sets of colored drawings in soft copy in cd and 10 nos of data in hard copy in good quality paper approved by garrison engineer. , soil investigation of blgs to be carried out by a nabl accredited soil investigation agency govt engg college as per nbc is 1802 2131 2132 1888 2720 1904 6403 8009 1498 4968 and sp36. making bore hole of 150 dia upto 6 mtr depth below ground level collection of disturbed and undisturbed soil sample of an internal range of 1 mtr to 2 mtr performing spt at an interval of 0.75 mtr depth or at every change of soil starta which ever encounter first incl soil classification tests and bore hole of log data and evalution of safe bearing capacity and recommendations of type of foundations for suitability of earth obtain from foundation trenches including salinity test and chemical analysis of soil including following details. please see specification of document. , ditto- same as item no 2 above but depth upto 10 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation. , ditto- same as item no 2 above but depth upto 15 mtr or n value reaches 50 , whichever is earlier for isolated/combined/raft foudation.however depth of bore holes may be taken as 25 m for pile foundation.

State Government

CTN :39548311 Due date: 11 Mar, 202511 Mar, 2025 3.50 Lacs
Tender For maintenance of solar power fencing from poochakulam-thumpakulam (5point5 km into 5 line 2020 2021 installed) under gurunathanmannu forest station forest station of vadasserikkara range during 2024 25

Central Government/Public Sector

CTN :39171113 Due date: 15 Mar, 202515 Mar, 2025 1.80 Crore
Tender For corrigendum : replacement of security equipment installations at dmde office complex under ge i rnd kanchanbagh, hyderabad - supply and fixing of electric fencing - 520 rm as specified below as per site requirement including taking down existing fencing with all connected accessories viz. energizer, boom barrier, hydraulic tyre killer, turnstile gate, swing lane barrier, fencing posts, fencing wire, insulators, door frame metal detector etc, complete all as specified and directed by engineer-in-charge., (a) general description(a) this scope involves, design, supply, installation, testing and commissioning of a non-lethal high security. electrical fencing for the purpose of deterrence, detection, and movement control of people / unwarranted trespassing into the premises for 520-meters perimeter length.(b) anyone who touches the power fencing when the system is armed shall be repelled by a short, sharp, painful, but safe pulsed dc high voltage shock. alarms shall be generated when someone touches, tries to climb through or tampers with the power fencing system., (c) the electric fencing shall be divided into two zones.(d) this system should be able to alert security personnel of an attempted intrusion and identify the zone around the perimeter of the site.(e) the electric fence is to be installed on the existing wall and the height of the fence will be 1.1 meters from top of the wall with 11 nos. of fence wires having 100mm gap between adjacent wires and it measure 1mtr.(f) electric fence posts are to be hot dip galvanized., (g) distance between strain fence posts spacing shall not exceed 50-meter nominal.(h) distance between intermediate fence posts spacing shall not exceed 3-meter nominal.(j) the electric fence shall incorporate uv stabilized intermediate post insulators.(k) warning signs shall be mounted around the fence line at intervals not exceeding 10m or at every turn on the physical fence.(l) dual zone fence energizer shall be installed to create 2 zones at site., (m) one dual zone led keypad shall be connected to fence energizer for local control and programming purpose.(n) a touchscreen controller should be placed in control room. fence energizer should communicate with touch screen controller over rs485 network.(o) the space between adjacent wires on the electric fence shall be no more than 10cm.(p) anti-climb configuration at strain points shall be provided. electric fence wire shall be looped around the strain post and connected back onto itself.(q) all high voltage impulse wiring shall be run in conduit separate from any other wiring.(r) the fence energizer shall be mounted in the weatherproof enclosure.(s) the energizer should comply with iec 60335-2-76 and is302-2-76 standards., (b) technical specification (electric fence system):energizerthe fence energizer should have the following minimum features: energizer should be dual zone with independent zone control. energizer should communicate with control room on rs485 network. energizer should have lcd display with background colours which changes according to the status of the energizer. green colour should indicate that all is fine, orange indicate that attention is required and red indicates an alarm condition., energizer should display the following information when specific codes are inserted from keypad: fence health on a scale of 1 to 9 for each zone independently, fence output voltage, fence return voltage, energy stored, capacity used and battery voltage. output energy 3.7 joule with 500 ohms load. pulse interval 1 sec. pulse duration should be less than 0.1ms. energizer should have apt - adaptive power technology functionality. which means the energizers should offer a unique technology to detect how much power a fence can accept and handle before it starts to arc and waste energy. this maximises the power on the fence and minimises false alarms., individual high voltage transformer for each zone. magnetic tag switch should be provided for on/off the ene
 Loading, Please wait...

Connect us via What's Up