Tender For bid to ras corrigendum : supply of dc lead acid or ni cd batteries for ntpc lara project - 220v lead acid or ni cd battery suitable for main plant , electrolyte for first filling plus 10percent extra in nonreturnable container , wooden racks , stand insulators , intercell, inter row, inter bank connectors , cell numbering tags with fixing arrangement 1set , anti-splash type vent plug , nickle coated connection hardware plus 5percent extra , cable clamps with fixing hardware , pvc or cfrp spill trays under battery set battery to have spill tray covering every cell , battery trolley for entire project , hydrometer , cell testing digital voltmeter 3-0-3v with testing leads , wall mounting type holder for hydrometer and thermometer , set of hydrometer syringes suitable for vent holes in different cells , thermometer for measuring electrolyte temperature , specific gravity correction chart for lead acid battery only , rubber apron , pair of rubber hand gloves , set of spanners , no smoking notice , goggles industrial , instruction card , minimum and maximum temperature indicator for each battery room , acid or alkali mixing jar , battery health monitoring system for each battey cell of battery sets as per sl.no. a.1.1 above , 220v lead acid or ni cd battery suitable for offsite area , electrolyte for first filling plus 10percent extra , ms racks properly treated with alkali resistance powder , stand insulators plus 5percent extra , intercell inter row inter bank connectors , e and c spares for battery 1 and 2 gloves , e and c spares for battery 1 and 2 vent plugs , e and c spares for battery 1 and 2 intercell connectors , supervision of erection -battery -mandays , supervision of erection -battery -visit , supervision of commissioning -battery -mandays , supervision of commissioning -battery -visit , supervision of commissioning -bhms -mandays , supervision of commissioning -bhms -visit , mandatory spares for battery 1 complete dry cell , mandatory spares for battery 1 inter-cell connectors with hardware , mandatory spares for battery 1 bhms spares , mandatory spares for battery 2 complete dry cell , mandatory spares for battery 2 inter-cell connectors with hardware
Tender For supply of ht starter spares of prabhu make c c -isolator 400amps 3. 3kv reversing part no ht100b , isolator 200 amp 3. 3 kv on off part no ht100 , vacuum contactor 400 amps 3. 3kv part no ht200 , bridge rectifier unit complete part no ht005 , vacuum interrptor 3. 3kv 400a part no ht202 , vaccum contactor closing coil 110v dc part no 203 , vaccum contactor holding coil 110v dc part no 204 , auxiliary switch for vaccum contractor 2 part no 205 , p. t. 40va 0 8 12v 0 110v part no 206 , auxiliary contactor 3no 1nc 110v ac part no 208 , resin cast p t 750va 3. 3kv 110v single part no 300 , resin cast p t 300va 3. 3kv 110v 3 phase part no 350 , ht control fuse 3. 3 kv. 2 amps part no 400 , resin cast moulded cbct part no 500 , resin cast moulded ct for o l relay 100 part no ht600 , resin cast moulded ct for ammeter 150 5 part no ht650 , e. l. unit complete without transformer part no 800 , ct oprtedct sec 5a motor prtectn relay part no ht900e , o l rly thrml 4 7 5a ct oprtd w mntng part no 900b , 72sq. mm ammeter 0 150 450a part no ht1000 , 72sq. mm voltmeter 0 5kv part no ht1100 , ammeter selector switch part no 1001 , hrc fuse base carrier for control part no 1200 , hrc fuse link 4a for control part no 1201 , push button with element for start sto part no ht1300 , lamp holder with lamp on off trip part no ht1400 , power hrc fuse part no 1500 , single phase preventer cup 20 pfr make part no 2001 , copper bus bar 400 amps set of 3 part no ht101 , undervoltage relay part no ht2000 , static type idmtl over current and short part no ht900a , pilot realy 12dc part no ht2200 , voltmeter selector wsitch part no ht1101 , contactor tp. 12 amps ac3 duty fitted wit part no ht200a ) /bid number: gem/2025/b/6879193 * /dated: 11-11-2025 & & / bid document1 / 26
Tender For supply of ord head d d - self starter assy , bty lead , body light , push button , oil pressure pipe , clutch pressure plate kit , on off switch , dc voltmeter , voltmeter 500v , ampere etre 0 ton 50amp , ignition switch , combination switch , 4st relay 12v
Tender For supply of procurement of spares for breaker and control panel c c - current transformer ctr 400 5a , epoxy resin cast current transformer rat , expoxy resin cast current transformer 20 , current transformer ctr 600-300 5 , vcb limit switch , vtc closing coil 110 v dc , plug and socket 19 pin , vcb 11 kv 1250a25kambl , anti pumping relay 11 pin 110v ac , aux. contactor pak 6u544 w 0468151 , draw out handle , breaker charging handle , shunt trip coil 110 v dc , mechanism catch 25ka , machanism motor wound spring charged 25k , rectifier bridge unit 60 63a 600piv 100v , auxiliary contactor 110v. , bushing pad 175 875a , voltmeter 0-8kv sf 96 mm 6. 6kv 110v , ammeter sf 96 sq mm ctr 200 11a , lmp ind 7wt 110v w hldrw o lens bch , sw v meter selector srp-135 v , switch auxiliary assly 8-way , lighting arrestor. 6. 6kv , spout bus bar 1000a , idmt relay , relay e l 50a 1a 110v ac ) /bid number: gem/2025/b/6875500 * /dated: 11-11-2025 & & / bid document1 / 26
Tender For purchase of lab equipments for ece dept - purchase of lab equipments for ece dept, sim reader trainer kit, directional characteristics of horn antenna, single phase auto transformer (0-300v), single phase transformer 230/115v, single phase transformer 115/230v, digital voltmeter (0-100v) dc
Tender For supply of lte mobile trainer kit , am modulaor demodulator kit , psk modulator demodulator kit , qpsk modulator demodulator kit , fm modulaor demodulator kit , am transmitter kit , arduino kits with modules , trainer board to study mux and demux , function generator , dc regulated power supply , trainer board to study the effects of negative feedback on the amplifier characteristics , trainer board of two stage transformer coupled amplifier , trainer board of two stage direct coupled amplifier , trainer board to study characteristics of class a amplifier , trainer board to study colpitt s oscillator , plc trainer kit , optical fiber splicing machine , optical time domain reflectometer , pcb etching machine , pcb drilling machine , portable wattmeter , portable moving iron voltmeter , portable moving iron ammeter , portable standard energy meter , single phase power measurment kit , digital energy meter , sliding rheostats , tachometer , three phase lamp load , single phase lamp load , single phase transformer , trainer board to study chopper , trainer board to study dual converter , trainer board to study cycloconverter , scr based lamp intensity control , voltage line tester , voltage line tester non-contact , multipurpose wire stripper and cutter , round wire gauge , dol starter , display board - different switches , display board - different wires and cable , model cut section ceiling fan ) /bid number : gem/2025/b/6844196 * /dated: 04-11-2025 & & / bid document 1 / 35
Tender For rca for procurement of local purchase materials required for operations and maintenance of equipmets of 33/11 kv s/ under city cirle bhopal. - various tripping coil, various closing coil, expulsion fuse 20 a. for capacitor bank ( for 100 kvar unit ), expulsion fuse 40a for capacitor bank ( for 200 kvar unit ), silica gel, breather for ptr (capacity- 3 kg.), robust high ampacity smart connector for ct/pt/me, m-16, robust high ampacity smart connector for ct/pt/me, m-20, c&r panel indicators, tnc switch, mfm, buchholz relay, mog, 11 kv vacuum interrupter make- cg (suitable for cg/megawin/bhel), 11 kv vacuum interrupter make- stelmec (suitable for stelmec), robust high ampacity smart connector for ptr of size m-20 for raccoon/dog, robust high ampacity smart connector for ptr of size m-20 for panther, gi nut bolts assorted size, rubber cork seat 4 mm, rubber cork seat 10 mm, oil temperature indicator (oti), winding temperature indicator (wti), smart t clamp of all sizes, smart pg clamp of all sizes, isolator pad clamp, 30 volt dc bell, ampere meter selector switch, voltmeter selector switch, dc mcb 16 amp, ac mcb 16 amp, mft (multi-functional transducer), cmr ( contact multiplying relay), auxiliary switch-8 no+8 nc ( suitable for the vcb s of different makes), spring charging motor (suitable for the vcb s of different makes), pull rod suitable for vcb s of different makes, fuse wires tinned copper 15 swg, fuse wires tinned copper 16 swg, fuse wires tinned copper 18 swg, fuse wires tinned copper 12 swg, fuse wires tinned copper 21 swg, fuse wires tinned copper 14 swg, aluminium lugs 70 sqmm, aluminium lugs 95 sqmm, aluminium lugs 150 sqmm, aluminium lugs 300 sqmm, do fuse elements 1 amp., do fuse elements 1.5 amp., do fuse elements 3.3 amp., do fuse elements 3 amp., do fuse elements 5 amp., do fuse elements 10 amp., do fuse elements 15 amp., male/female contacts for 11 kv ab switches 400 amp., male/female contacts for 33 kv ab switches 600 amp., aluminium ladder, smart connector suitable for ab switch terminal (50x50) to dog raccon conductor, smart connector suitable for isolator/ cb (75x75 mm) terminal to dog/ raccorn conductor, kit kat fuse unit 300 amp., kit kat fuse unit 200 amp., robust lt pole fuse unit, hrc fuse base100 amp., hrc fuse base 200 amp., hrc fuse base 250 amp., hrc fuse base 400 amp., torch cell 1.5 volt, pvc insulation tape, rubber hand gloves 11 kv, rubber hand gloves 33 kv, sefty helmet, discharge rod, gum boot, sefty bellt jhula, screw driver 12, screw driver 6, screw driver 8, pencil type neon tester, insulated combination cutting piler 8, lineman tool bag, rubber conical washer rubber conical washer suitable for 12 mm stud(hv side), rubber conical washer suitable for 12 mm stud (lv side), bamboo ladder, street lights (including dual fixtures) power rating: 200 watt, tong tester, multi meter, insulation megger tester, earth resistance tester, ac volt meter, ac amp. meter, dc volt meter, dc amp. meter
Tender For supply of spares for trus and cppsm units at vvspl locations c c - dc o or p voltmeter , dc o or p ammeter , ac i or p voltmeter , ac i or p ammeter , psp voltmeter , control card 103a , control card 104c1 , control card 105d1 , control card 106zn , control card 107 , o or p contactor tru , psp transducer tru , gps antenna tru , gps timer tru , sply of permanent ref cell , surge diverter , o or p voltage transducer tru , o or p current transducer tru , fuse link ns10a , toggle switch 2 pole 2 way , display board for ks db01 , mother board for ks mb01 , aux transformer , control card 118b , control card 118c , lightning arrestor , rb1 bleeder resistor , filter control circuit sply , filter capacitor , diode 70 hmr 150 or 120 , diode 150 lf 120 , cu cuso4 half cell , ref voltmeter selector switch 8 way , mains on indicator 22 5 dia with washers , ref fail setting card , scr tail type , ref electrode selector switch 4 way , dc output voltmeter cppsm , dc input ammeter cppsm , dc input voltmeter cppsm , dc output ammeter cppsm , psp voltmeter cppsm , control card ceco104c1 cppsm , control card ceco106 cppsm , control card ceco107 cppsm , control card ceco103b cppsm , control card ceco30r cppsm , control card ceco31r cppsm or tru , o or p contactor cppsm , gps antenna cppsm , gps timer cppsm , psp transducer cppsm , voltage transducer cppsm , current transducer cppsm , display board for cppsm , mother board for cppsm , ref fail setting card cppsm , ammeter w or ext shunt , rb1 bleeder resistor cppsm , transistor evl31 050 , 32a small fuse holder , glass fuse cppsm or tru , variable resistor ajb , shunt 50mv 5 a , shunt 50mv 10 a , shunt 75mv 75 a , galvanic isolator 230v ac or 48v dc
Tender For supply of electrical ee2 d d -experimental kit for the measurement of displacement using lvdt 6 , experimental kit for the measurement of displacement using lvdt 7 , inductive load bank 1 , inductive load bank 2 , kelvin double bridge 1 , kelvin double bridge 2 , kelvin double bridge 3 , kelvin double bridge 4 , kelvin double bridge 5 , kelvin double bridge 6 , m. i type analog ammeter 0 1 a 1 , m. i type analog ammeter 0 1 a 4 , m. i type analog ammeter 0 1 a 2 , m. i type analog ammeter 0 1 a 3 , m. i type analog ammeter 10 20 a , m. i type analog ammeter 2. 5 5 a 1 , m. i type analog ammeter 2. 5 5 a 2 , m. i type analog ammeter 5 10 a 1 , m. i type analog ammeter 5 10 a 2 , m. i type analog ammeter 5 10 a 3 , m. i type analog ammeter 5 10 a 4 , m. i type analog ammeter 5 10 a 5 , megger hand driven 1 , megger hand driven 2 , megger hand driven 3 , megger hand driven 4 , megger hand driven 5 , mi type analog voltmeter 125 250 500v , mi type analog voltmeter 300 600v 1 , mi type analog voltmeter 300 600v 2 , mi type analog voltmeter 300 600v 3 , mi type analog voltmeter 300 600v 4 , mi type analog voltmeter 300 600v 5 , mi type analog voltmeter 75 150 300v 1 , mi type analog voltmeter 75 150 300v 2 , mi type analog voltmeter 75 150 300v 3 , network theorem trainer kit 1 , network theorem trainer kit 2 , network theorem trainer kit 3 , orifice meter measurement setup 1 , orifice meter measurement setup 2 , orifice meter measurement setup 3 , phase sequence indicator 1 , phase sequence indicator 2 , rheostat 0 100 ohm,2. 5a , rheostat 0 100 ohm,5a 1 , rheostat 0 100 ohm,5a 2 , rheostat 0 250 ohm, 2. 5 a 1 , rheostat 0 250 ohm, 2. 5 a 2 , rheostat 0 250 ohm,1a , rheostat 0 50 ohm,5a , rheostat 0 500 ohm, 2. 5 a , rotameter flow measurement setup 1 , rotameter flow measurement setup 2 , rotameter flow measurement setup 3 , rtd temperature measurement setup 1 , rtd temperature measurement setup 2 , strain gauge trainer kit 1 , strain gauge trainer kit 2 , strain gauge trainer kit 3 , strain gauge trainer kit 4 , strain gauge trainer kit 5 , strain gauge trainer kit 6 , three phase load rheostat 1 , three phase load rheostat 2 , three phase load rheostat 3 , three phase load rheostat 4 , three phase load rheostat 5 , three phase power factor meter 1 , three phase power factor meter 2 , three phase power factor meter 3 , three phase power factor meter 4 , three phase power factor meter 5 , three phase synchronous motor coupled with dc shunt generator setup 1 , three phase synchronous motor coupled with dc shunt generator setup 2 , three phase synchronous motor coupled with dc shunt generator setup 3 , three phase synchronous motor coupled with dc shunt generator setup 4 , three phase veriable resistive load 1 , three phase veriable resistive load 2 , three phase veriable resistive load 3 , transmission line protection simulation kit 1 , transmission line protection simulation kit 2 , transmission line protection simulation kit 3 , transmission line protection simulation kit 4 , transmission line simulator 1 , transmission line simulator 2 , transmission line simulator 3 , undrground cable fault locator 1 , undrground cable fault locator 2 , undrground cable fault locator 3 , venturi flow measurement setup 1 , venturi flow measurement setup 2 , venturi flow measurement setup 3 , wattmeter 0. 5 1a, 150 300v low power factor , wattmeter 10 20 a ,150 300 600v unity power factor 1 , wattmeter 10 20 a ,150 300 600v unity power factor 2 , wattmeter 10 20 a ,150 300 600v unity power factor 3 , wattmeter 10 20 a ,150 300 600v unity power factor 4 , wattmeter 10 20 a //bid details2 / 127,150 300 600v unity power factor 5 , wattmeter 10 20 a ,150 300 600v unity power factor 6 , wattmeter 2. 5 5a , 150 300v unity power factor 1 , wattmeter 2. 5 5a , 150 300v unity power factor 2 , wattmeter 2. 5 5a , 150 300v unity power factor 3 , wattmeter 2. 5 5a , 150 300v unity power factor 4 , wattmeter 5 10 a ,150 300 600v unity power factor 1 , wattmet