Tender For corrigendum : supply of design and supply of 11 kv, 630a, 25ka,erection, testing and commissioning of 11 kv, 630a, 25ka,supply of earthed armoured,aluminium conductor xlpe powercable,laying of earthed armoured,aluminium conductor xlpe powercable,supply and making straight through joint with cast resin compound,supplying and making end termination with brass compression gland and ai.lugs,supply of control cable pvc insulated, sheathed, unarmoured, flexible copper conductor cables,laying and connectorization of control cable pvc insulated, sheathed, unarmoured, flexible copper conductor cables,supply part for maintenance free earthing system,service part for maintenance free earthing system,supply of 50x6 gi strip,laying of 50x6 gi strip,removing and dismantling of existing ht panels and shifting to store,supply and placement of 3 mm thick rubber mat. class b,supply, fabrication and installation of ms items,supply and installation shock hazard charts complete with frame and glass in english and hindi,supply and installation first ai
Tender For supply of ems shifting and installation for dgm office at te kankaria ahmedabad d d -point wiring group c , wiring with 2c 1. 5sq mm cu wire in pvc conduit with earthing , wiring with 2c 6sq mm cu wire in pvc conduit with earthing , s drawing 3c 1. 5 sq mm cu wire in extg conduit , s drawing 5c 1. 5 sq mm cu wire in extg conduit , s drawing 5c 2. 5 sq mm cu wire in extg conduit , s fixing piano switch 5 or 6 amp , s fixingpiano switch 15 or 16 amp , s fixing 3 pin 5 or 6 amp socket outlet , s fixing 6 pin 15 or 16 amp socket outlet , s fixing metal box with lamnated sheet cover 6 module , s fixing 5 or 6 amp modular switch , s fixing 3 pin 5 or 6 amp socket outlet , s fixing 2 stepped electronic regulator , sf modular blanking plate , s fixing single pole 5 to 32 amp mcb , s fixing single pole and neutral 5 to 32 amp mcb , s fixing 20w led in extg fitting , s fixing recessed luminire with led etc as per site reqd , sitc celing fan 1200 mm bee 3star , itc extg tl and cfl fittings , itc extg ceiling fans , sf of downrod 15mm dia gi pipe of 20cm length , endtermi for 4 c 35 sq mm al cable , endtermi for 4 c 10 sq mm al cable , laying on wall upto3. 5c 35 sq mm cable , pf 6 swg gi earth wire , s fixing 8 way double door mcb db 240v , dismentaling extg ei fittings fans wiring etc , dismentaling window or split ac units , itc of 1. 5 or 2 tr split ac units , s f powder coated iron stannd of ac outdoor unit , sf add 0. 25 inch copper pipe with cable for sac , sf add 0. 625 inch copper pipe with cable for sac , wrapping polythene foam tube on 0. 25 inch copper pipe , wrapping polythene foam tube on 0. 625 inch copper pipe , sf 3 c 2. 5 sq mm cu cond flexible cable , sf 20 mm pvc isi drain pipe
Tender For corrigendum : supply of supply installation testing and commissioning of 1600 kva 11 by 0.433 kv delta star step down as per atc attached , supply installation testing and commissioning of 11 kv 630a rated breaking capacity 21ka for 3sec sf6 insulated rmu as per atc attached , sitc of 2500 amps sandwich type bus trunking as per atc. , supplying and laying of 3 core 150 sqmm xlpe insulated cable on the existing cable tray or rcc or hume or metal pipe or susface as per atc attached , supplying and laying of 3 core 150 sqmm stranded aluminium conductor conductor screen with extruded semi conducting compound xlpe insulated cable in the existing masonary duct as per atc attached , supplying and makingoutdoor cable end termination with heat shrinkable joint for 3 core 150 sqmm 111 kv grdae as per atc attched. , copper plate earthing complete as per atc attached. , gi plate earthing complete as per atc attached. , providing 50 mm and 5 mm thick copper strip on surface as per atc attached. , providing 25 mm and 5 mm thick copper strip in 40 mm gi pipe as per atc attached. , providing 25 mm and 5 mm thick copper strip on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class on surface as per atc attached. , supplying and laying of 80 mm gi pipe a-class in ground as per atc attached. , supplying and laying 120 mm dia dwc hdpe pipe as per atc attached. , supply and installation of 4.5 kg co2 type fire extinguisher isi marked as per atc attached. , supply and installation of 06 kgs abs powder type fire extinguishers as per atc attached. , supply and installation of 3 mm thick rubber mat suitable for 33 kv as per atc attached. , supply and installation 0f 4 nos 9.5 ltrs capacity gi bucket as per atc attached. , supply and installation of first aid box as per atc attached. , supply and fixing safety instruction chart as per atc attached. , supply and fixing shock treatment chart as per atc attached. , supplying and fixing of 40mm x 40mm x 5mm thick angle iron frame complete as per atc attached. , supplying and fixing of single line diagram and layout diagram complete as per atc attached.
Tender For supply of replacement and provision of led lights at chandigarh airport d d -supply of 350w led flood light , itc of 350w led flood light , supply of 80w led flood light , itc of 80w led flood light , supply of 200 w led highbay luminaire , itc of led highbay luminaire 200 w on existing ceilings with a 400mm diameter round cutout at height of approx 10-12 m , itc of led highbay luminaire 200 w on existing ceilings with a 400mm diameter round cutout at height of approx 18-20 m , supply of 80w led highbay luminaire , itc of led highbay luminaire 80w at height of approx. 9-11 m , supply of 96w led recessed canopy or highbay luminaire , itc of led recessed canopy or highbay luminaire 96w on acp ceilings with a rectangular cutout of approximately 270mm x 300mm at height of approx 7-10 m , supply of 120w led street light , itc of led street light 120w on 9 meter street light pole , supply of nerrow beam 400w to 500w led flood light , itc of nerrow beam 400w to 500w led flood light , supply of 10w recessed square led decorative downlight , itc of led light fixture 10w on existing acp ceilings square cutout of approximately 110mm x 110mm , supply of 36w led recessed 2x2 light panel , itc of led recessed 2x2 light panel 36w , supply of two 18 to 20w led t8 tubes with weatherproof housing of 4 foot length , itc of two 18 to 20w led t8 tubes with weatherproof housing of 4 foot length , supply of 35w surface-mounted circular ring minimum outside diameter of 600mm , itc of surface mounted 35w circular ring type led light fixture , supply of 40w recessed tiltable cob led downlight , itc of led light fixture of range 40 w , supply of 15w led recessed round down light , itc of 15w recessed led light fixture , supply of 1. 5 mtr long each arm hot dip galvanised double arm standard bracket , itc of 1. 5 mtr long each arm hot dip galvanised double arm standard bracket on 9 meter street pole , supply of 3 core 2. 5 sq mm size, pvc insulated copper conductor flexible cable , laying of 3x 2. 5 sq mm cable
Tender For supply of supply and installation of 20 kva dg set at keating point lighthouse : : - supply and installation of 20 kva dg set , transportation sea freight loading and unloading the dg set upto keating point lighthosue , supply and installation of of armoured cable 2 core 25 sqmm , supply and installation of earthing , supply and installation of copper strip , laying of cable and dg set installation , supply and installation of amf panel , consumable of spares for 02 years
Tender For supply of concealed point wiring comp with 1. 5 sq mm frlsh,pvc 1 multi standard copper conductor 1 core cable 1100 v gd for one 15 a socket outlet but using 2. 5 sqmm frls copper conductor , s and f single pole and neutral db wall mounting type, 240 volts, 8 way with 100 amps rated bus bar, double door suitable for fixing mcbs including connecting etc , s and f wall mounted fan 450 mm turbo metal body with all accessories all as specified and as directed , supply and fix in replacement vertical tpn db 4 way in double door 415 volt all as specified and as directed. make-legrand cat no 507745 , material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground , automatic organic waste machine, per day waste processing capacity 250 kg features per day waste processing capacity of composting system- 250 kg per day , installation testing and commissioning of automatic organic waste machine cap 250kg , automatic organic waste machine, per day waste processing capacity 500 kg features per day waste processing capacity of composting system- 500 kg per day , installation testing and commissioning of automatic organic waste machine cap 500kg , automatic organic waste machine, per day waste processing capacity 1000 kg features per day waste processing capacity of composting system-1000 kg per day , installation testing and commissioning of automatic organic waste machine cap 1000kg per day , kill waste unit of capacity 80kg per hr material non-corrosive mild carbon steel of is2062-grade b category cylindrical chamber as specified by bis, manufactured by jindal steel thickness 5mm , installation,testing and commissioning of kill waste unit of capacity 80kg per hr , bailer of 5hp specification for balling press machine capacity- 20ton weight of bale-50-60 kg bale size lxwxb-700mm x 500mm x 650mm , installation,testing and commissioning of bailer 5hp, machine capacity 20 ton , excavation in trenches in soft by loose soil n exceeding 1. 5 m depth and in exc 1. 5 m width for foundation etc or for shafts cesspit mainhole pier holes etc , excavation in trenches in hard by dense soil not exceeding 1. 5 mir wide and not exc 1. 5 m depth for laying of gl pipes and getting out all as specified and directed. , m and l for machine pressed precast conctete interlocking paver block any shape and size confirming to is 15658-2006 of 60 mm thickness , m and l for providing and laying at or near ground level factory made kerb stone of m-25 grade cement concrete in position to the required line, level , m and l for plain cement concrete 1-2-4 type b-0 using 20 mm graded stone aggregate as in sub base of floor complete all as specified and as directed , removing of excavated earth to a distance beyond 50m and upto total distance 250m , removal of surplus excavated solid to a distance exc 50m and n exc. 250m and deposting where directed at a level n. exc. 1. 5m above the starting point complete , s and f gl water tubing, medium grade, 20 mm dia, incl fittings by accessories like sockets, bend, elbow, union exc laying in trenches including taking out old us pipe all as specified and directed , s and f gl water tubing, medium grade, 25 mm dia, incl fittings by accessories like sockets, bend, elbow, union etc laying in trenches including taking out old us pipe all as specified , s and f gl water tubing, medium grade, 50 mm dia, incl fittings by accessories like sockets, bend, elbow, union etc laying in trenches including taking out old us pipe all as specified and directed. , m and l for gunmetal globe by gate valve with iron wheel head, screwed both //bid details3 / 79ends of sizes 50 mm isi marked all as specified and directed , construction of brick masonary valve chamber with 3. 00 mm thick ms sheet cover and angle iron frame of size 40 x40x6 mm , supply and fix stop valves 25mm dia cast copper alloy scrawed down high pressure,. with crutch or butterf y handle, screwed both ends for iron pipe
Tender For corrigendum : ridf xxviii - lift irrigation projects in various padashekharams of wayanad district- procurement of submersible pumpsets, fittings, accessories, and related electrical works - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses. - procurement, installation, erection, testing, and commissioning of pumpsets and allied works at punchavayal, manikkuni, kolembetta, valiyavattam, and padiyeri pumphouses., supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontally mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day night operation.the pump discharge capacity of 230 cubic metre /hour against duty point head of 42 mtrs, working head range 18 - 47m, discharge range 136 - 57 lps ,speed 1450rpm(n) or nearer ,with 10meters of copper powercable and control cable, railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided with an additional iron grill for preventing foreign particles inside the inlet side of the pump casing., supply and erection of 60hp auto transformer starter (ats) with suitable incommer and contactors including 24 kvar capacitor with required indications ,metering and protections for single phasing ,overload, pump monitoring unit to protect from ingress, high temperature level etc enclosed in a closed panel board, supply and laying additional termination cable of 1.1kv 3.5 core 95sqmm aluminium conductor xlpe insulated ;steel armoured ug cable as per relevant is 7098 with support for cable, supply, installation, erection, testing, commissioning and fitting charges for all accessories of horizontzlly mounted submerged centrifugal non clog pump set of compact unitary mono-block submerged single/multi stage,volute type casing with suitable radial type impellers on common shaft for pump and motor ,anti friction bearing with life time greasing, protection features with sensors to monitor temperature,mechanical seal leakage ,etc.(the pump should be confirming to his/is standards).the moc of pump,casing-cast iron,impeller -ss cf8m,shaft-ss-316,suction strainer -ss and other as per is standard.the motor should be suitable for 3 phase,415v /-10%,50hz /5%,ac supply submersible motor having class f /h insulation, air filled and ip-68protection confirming to is 325 or latest standards suitable for day nightoperation.the pump discharge capacity of 188 cubic metre /hour against duty point head of 35 mtrs,working head range 16 - 42m, discharge range 102 - 42 lps ,speed 1450 rpm(n) or nearer ,with 10meters of copper powercable and control cable,railing arrangement. the pump should be painted with three coats of suitable anti corrosive paint over priming coat. the electrical works for the pumpset should be completed as per kseb rules and regulations and the contractor is responsible for arranging premissions and certificates from the electrical inspectorate. the suction side of the pumpset should be provided wi
Tender For supply of providing electrical infrastructure work for ht to lt powr supply conversion at te lal tekri : - dismantling of existing 3. 5 core al armoured cable , disconnection of terminations of all cables , supplying laying 3. 5 core 50 sqmm xlpe armoured cables with copper conductor , supplying and making end termination3. 5 core 50 sqmm , supplying and fixing of 3 nos 500 amps ceramic cut-out fuse with base , supplying and fixing of 50 mm copper cable lead wire , supplying and fixing of 125 amp tpn sfu switch with enclosure , supplying and fixing of 100 amp four pole rccb , supplying and fixing suitable size of enclosure box , providing and fixing 8 swg dia g i wire
Tender For brief scope of works includes-a) design, manufacture and supply of 2 nos. of 3ph, 750kva, 11kv/433v, onan, dyn11, outdoor type, copper wound generator auxiliary transformer with off load tap changer. b) supply of 400sq.mm, 3.5 core, 1.1kv grade, pvc armored, copper lt powercable along with cable termination accessories required for connecting lv side of auxiliary transformer to ltac panel. c)supply of essential spares as per the bid requirement d) laying and termination of supplied 400sq.mm, 3.5core copper cable from auxiliary transformer to ltac panel along with necessary termination accessories. e) dismantling of old 2 nos. of 750kva, 11kv/400v auxiliary transformers along with old oip cables connected from auxiliary transformers to ltac panel. f) erection, testing and commissioning of newly supplied 3ph, 750kva, 11kv/433v auxiliary transformers.