Tender For supply of sitc of scctv system at isolation bay of rupsi airport c c -supply installation testing and commissioning of providing joints by using brazing technique , supply installation testing and commissioning of copper bonded rod with low carbon steel high tensile strength copper bonded rod with min 254 microns of copper plating , excavation of soil for making trench , laying or fixing of hdpe conduit or pipe underground or surface complete as required as per site condition , laying of 25mm pvc pipe , laying of 25mm pvc flexible pipe for indoor complete as required , laying of 25 or 32mm pvc reinforceable flexible pipe complete as required , laying of optical fiber cable end to end ferruling labeling and termination through gi conduit or pvc pipe complete as required , laying of cat6 utp end to end ferruling labeling and termination through pvc pipe complete as required , laying of electrical cable end to end ferruling labeling and termination through gi conduit or pvc pipe complete as required , mounting and fixing of gi pole after excavation of soft or hard soil including cutting of bituminous road or pavement , mounting fixing labeling and dressing of floor standing rack complete as required , mounting fixing labeling and dressing of 6u pole mount rack complete as required , mounting fixing and labeling of all types of cameras complete as required , installation splicing of all ofc core rack to server rack labelling testing and commissioning , installation of db , installation of 2 x 15- or 16- amp shuttered switch socket combined with cover plate and back box for surveillance room end , installation of electrical box with 25 amp mcb 15 or 16 amp socket at rack end , installation testing and commissioning of 5kva online ups with 60 min backup including ups output electrification complete as required , installation testing and commissioning of nvr primary and redundancy complete as required , termination and fixing of category 6 utp information outlet , mounting fixing installation and configuration of all types of switches complete as required , installation and configuration of workstation complete as required , installation and configuration of point to multipoint radio with accessories complete as required , testing commissioning certification providing 3 sets of completion diagram and documentation of entire project complete as required
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; installation, testing and commissioning ip 67 flood lights 200 watt minimum luminous flux of luminaire 120 lm/w 64 nos, electrical system or installation; serv..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; providing and fixing following rating and breaking capacity and pole mccb with thermomagnetic release and terminal spreaders in existing cubicle panel board 1 n..,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; supplying & laying of pvc insulated and pvc sheathed/ xlpe aluminium powercable (armoured cable) 25 sq mm 250 mt; service provider,repair, maintenance, and installation of plant/ systems/equipments (version 2) - stadium; supplying, installation, testing and commissioning of cubical type indoor/outdoor lt panel board suitable for 415 v 3 phase 4 wire 50 hz ac supply system with ..,repair, maintenance, and installation of
Tender For supply of supply of sitc of various electrical lt switch gears control equipment and cables in the ltdb of power load c c - 630 amp 3 pole mccb 415 volt, , supply of spreader link for 630-amp 3 po , supply of extended rod with handle 630-a , supply of ring ct make- kappa, ratio60 , supply of 400 amp 3 pole mccb 415 volt, , supply of spreader link for 400-amp 3 po , supply of extended rod with handle 400-a , supply of ring ct make- kappa, ratio40 , supply of 200 amp 3 pole mccb 415 volt, , supply of spreader link for 200-amp 3 po , supply of extended rod with handle 200-a , supply of ring ct make- kappa, ratio20 , supply of 100 amp 3 pole mccb 415 volt, , supply of spreader terminal for 100-amp , supply of extended rod with handle 100-a , supply of ring ct make- kappa, ratio10 , replacement and retrofitting of 630 amp 3 , replacement and retrofitting of 400 amp 3 , replacement and retrofitting of 200 amp 3 , replacement and retrofitting of 100 amp 3 , supply of 95 sq mm single core copper fl , laying of 95 sq mm single core copper ca , supply, replacement and re-fixing of 95 , supply of indicating led lamp red- 60 n , replacement and re-fixing of indicating , supply of multifunction meter make- secu , installation, calibration, testing and ret , supply of auxiliary contactor for mccb m , ring ct installation and retrofitting , control cable connection and circuit mod , supply of 2. 5 sq mm flexible wire , supply of 400 amp 3 pole power contactor , supply of 160 amp 3 pole power contactor , supply of 160 amp 3 pole mccb for capaci , supply of spreader terminal for 160-amp , supply of extended rod with handle 160-a , replacement and retro-fitting of 400 am , replacement and retro-fitting charges fo , replacement and retro-fitting of 160 amp , supply of 12 window apfc relay, make- ep , replacement and retro-fitting charges fo , supply of 3-phase digital voltmeter make , supply of 3-phase digital ammeter make- , replacement and retro-fitting of 3-phase , rectification and restoration of mechanic , supply of 300 sq mm, 3. 5 core, 1. 1 kv gr , supply, fitting and fixing of gland for 30 , laying of 3. 5 core, 1. 1 kv grade armoure , supply and replacement of socket for 300 s , manual disconnecting of powersupply, di , supply, installation, testing and commis
Tender For laying at ltug cable ,ac repairs and other maintainance work & installation at ups system lakkundi circuit house and electrical maintaince at mundargi court building premises in gadag tq for the year of 2025-26
Tender For tender for the annual rate contract work of laying, commissioning and testing of 11kv ug xlpe cable & erection and maintenance of o/h 11 kv ht line/lt line (with bare conductor, mvcc or abc)transformer center, replacement of bare conductor & its accessories, etc.for shifting of electrical network from avdha to tutarkhed (r&b shifting works) and others scheme under jurisdiction of dharampur-1 sub division under dharampur division.
Tender For tender for supply of design and engineering of imcc panel 2 nos and vfds and plc network , design and engineering of apfc and hvac , design and engineering of apfc and field instruments , design and engineering of cables and termination and airconditioning for imcc building , design and engineering of earthing of imcc , field equipments and soil testing , design and engineering of civil buildings and structure foundations , design and engineering of imcc building with earthing system , design and engineering of structural works for cablelaying for both incoming and outgoing cables , design and engineering of lighting system of imcc building , equipment locations at ccr ground floor and along the structural path for cable route , design of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , supply of imcc panels , vfd panels , supply of apfc panels , hvac system/ air conditioning systems for imcc building and other area air conditioners as mentioned in scope of work , supply of mldb , lighting distribution boards , lighting material including db , light fittings , and all related accessories or wiring material and other electrics etc , supply of field instruments and necessary piping materials as required , supply of plc and other related required accessories , supply of lt cables and other related accessories for electrical , termination material and other instrumentation cables etc and other related electrics as required , supply of cable trays for electrical and instrumentation , supply of all earthing material as per is 3043 for imcc and connection to earth pits for motors , panels etc , supply of fire detection and alarm system for building and cable alley area along with integration and display at fire station/existing control centre , erection , testing , commissioning , and handover of equipments of imcc panels and vfd panels , erection , testing , commissioning , and handover of equipments of apfc panels and hvac system , erection , testing , commissioning , and handover of equipments of lighting system as per above supply , erection , testing , commissioning of earthing system , erection , testing , commissioning of field instruments and necessary piping materials etc as required , erection , testing , commissioning and handover of plc , erection , laying , testing and commissioning of lt cables cable terminations wherever required along with necessary accessories is in the scope of the contractor for electrical and instrumentation , erection , testing and commissioning of cable trays for electrical and instrumentation , erection , testing and commissioning of fire detection and alarm system for building and cable alley area along with integration and display at fire station or existing control centre , substructure excavation , foundation works footings , columns up to plinth level , dpc damp proof course , and backfilling. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork up to ground floor , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors up to ground floor. , superstructure columns , beams , slabs , brickwork or masonry for all floors above plinth level , and formwork for subsequent floors as per approved design , finishes plastering , flooring tiles , marble , painting , wall cladding , and other interior or exterior finishes , plumbing works , fixing of doors for subsequent floors as per approved design , supply and erection of structural works for cablelaying for both incoming and outgoing cables
Tender For memo no. 1073 /e-1375506 /ee-e/nkda/ elect/ 2025-26 - laying of main powersupplycable to the feeder pillar box and additional related electrical works to new street lights behind coffee house, nkda area, newtown, kolkata
Tender For providing of design installation and maintenance of educational lab/centre - vocational lab; site preparation, supply and installation of hardware, furniture; service provider,design installation and maintenance of educational lab/centre - smart class lab; site preparation, supply and installation of hardware, furniture; service provider - 65" interactive display, 75" interactive display, 86 interactive display, al training workstation, printer, computer chair, computer table, 600va ups system, 1000va ups system, 24 port switch, b port switch, 6u network rack, 4u network rack, 4 socket power strip, cat 6 cable, 2.5 sqm cable, 1.5 sqm cable, 1.0 sqm cable, 16a mcb, 25a mcb, 32a mcb, supply, foxing and commissioning of pvc casing-capping, structured network cabling laying, termination, and testing, electrical power cabling. installation and safety integration, comprehensive desktop/pc deployment & system configuration, integration & mounting of interactive display, supply, on-site delivery, and functional commissioning
Tender For supply of ac system of display hall c c -air diffusersorgrill with powder coated aluminium refer annexure iii , 100000000013 supply of return air diffusersorgrill with powder coated aluminium single piece refer annexure iii , 100000000014 supply of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iii , 100000000015 supply of fire dampers in supply air duct of required size controlwiring,the damper shall be motorised and spring return refer annexure iii , 100000000016 supply of control instruments and sensors required for combined fire and smoke damper including actuators refer annexure iii , 100000000017 supply of freshor exhaust air louvers made of extruded aluminium with birdor insect screen including volume control damper made of aluminium refer annexure iii , 100000000018 supply of floor mounted cubicle non drawout electrical control panel for operating 3 nos ductable unit and 1 no heater bank total 4 nos outgoing feeder refer annexure iii , 100000000019 supply of following size lt powercable with copper conductor xlpeorpvc insulation pvc inner sheathed armoured extruded pvc outer sheathed refer annexure iii , 100000000020 supply of xlpe insulated pvc sheathed armoured copper conductor 2xfy, 1. 1 kv grade lt cable of size 4. 0 core - 2. 5 sqmm refer annexure iii , 100000000021 supply of perforated hot dipped galvanised iron cable tray of size150 mm width x 50 mm depth x 1. 6 mm thickness refer annexure iii , 100000000022 installation testing and commissioning of high static pressure ductable ac unit capacity not less than 16. 5 tr having one indoor and refer annexure iv , 100000000023 erection testing and commissioning of high wall mount type hot and cold split ac units of cooling capacity not less than 2. 0 tr minimum 3 star rating inverter refer annexure iv , 100000000024 erection testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of ductable split ac refer annexure iv , 100000000025 erection, testing and commissioning of suitable size refrigerant grade copper piping between indoor and outdoor units of split ac refer annexure iv , 100000000026 laying of flexible pvc duct hose covering pipe gray colour of size 60 mm suitable for exposed refrigerant pipes and cabling refer annexure iv , 100000000027 laying of cpvc sdr11 pipe of 25 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000028 laying of cpvc sdr11 pipe of 32 mm dia with 9 mm thick tube type nitrile rubber insulation for condensate refer annexure iv , 100000000029 fabrication installation testing and commissioning of site fabricated gi sheet metal ducts of 24 guage birmingham gauge refer annexure iv , 100000000030 fabrication, installation, testing and commissioning of site fabricated gi sheet metal ducts of 22 guage birmingham gauge refer annexure iv , 100000000031 fixing of thermal insulation for supply air ducts with 19 mm thick self-adhesive closed cell elastomeric nitrile rubber class o refer annexure iv , 100000000032 fixing of acoustic insulation for ducting with open cell nitrile rubber insulation or open cell physically crosslinked polyolefin foam insulation refer annexure iv , 100000000033 erection testing and commissioning of volume control dampers for ducts made of gi sheet of thickness not less than 18 g including fittings refer annexure iv , 100000000034 fixing, testing and commissioning of supply air diffusersorgrill with powder coated aluminium single piece moulded frame refer //bid details2 / 31annexure iv , 100000000035 fxing, testing and commissioning of return air diffusersorgrill with powder coated aluminium single piece moulded frame refer annexure iv , 100000000036 erection testing and commissioning of 27 kw finned type electric strip air heaters for winter heating in three banks 9 kw in each bank refer annexure iv , 100000000037 fxing testing and commissioning of fire damp