Get complete information related to latest Power Transmission Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Power Transmission Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Power Transmission Tenders.
Tender For supply of portable battery-operated dc annual rate contract welding power source suitable for shielded metal annual rate contract welding (smaw) with accessories of esab renegade volt es 200i or equivalent brand and model as per annexure-a clause 8. [ warranty period: 30 months after the date of delivery ]
Tender For battery charger and discharging panel : "supply and commissioning of digital signal processing (dsp) controlled igbt based ac to dc rectification (converter) with active power factor correction with fine control on voltage regulation, ripple, thd and improved efficiency with re-generative feature suitable to provide float charging and boost charging of ni=cd battery 199ah/110v capacity.the technical specifications are as per enclosed annexure. [ warranty period: 30 months after the date of delivery ]
Tender For supply of pilot operated hydraulic dc valve to model no dg 5v-8s-6c-t-mu-b10 of m/s vickers or model no.4weh22j-7x/6e-w110-n9k4 of m/s rexroth for hydraulic power pack of hub cutter and speicial cranes in wheel shop. ]
Tender For supply of contactor 800a dc, 28v coil with 1no/1nc aux, contact , 400amps tp two way waith off switch , power module , battery 12v/12ah 4.0 kg, sealed & maintenance free
Tender For supply of digital insulation tester features pi (polarization index) measurement autopower off battery power indication external connection to 12v/1a power s supply over load protection testtime function setting, automatically run the measurement within the specified time. specifications- rated voltage 500v/1000v/2500v/5000v ac/dc, measuring range-500v/1000m!, 1000v/2g!, 2500v/100g! & 5000v/1000g!, open circuit voltage-dc 500v +30%, -0% -dc 5000v +20%, -0%, including inbuilt lithium iron rechargeable 12 volt battery. packing-gift box accessories testing cable, lead, power adapter and etc. [ warranty period: 30 months after the date of delivery ]
Tender For bid to ras supply of flexible copper trailing cables d d - item 10 , item 20 , item 30 , item 40 , item 50 , item 60 cable,trg,atc,3.3kv gr,3.5cx50mm2,is9968 size & tvpe 3.5cx50 sq. mm 3.3 kv grade flexible atc conductor of class-s, epr le-3, insulated &black hofr nbr pvc type se-4 sheathed flexible trailing cable suitable for reeling/un-reeling operation. cable type- flexible, standard: is 9968(part 2) 2002 d.c. resistance at 20deg. c (ohms/km) power core max- 0.393 earth core max - 0.795. annealing test in %- (before stranding) 13.5 %. per sulphate test in g/m2- max. 5.00. conductor screeninq power core only material approx thickness mm - extruded semiconducting compound/ extruded semi conducting tape- 0.80. conductor material: annealed tinned copper, 6.6 klv grade, cable type: flexible, standard: is 9968(part 2) 2002 tests on insulation thickness (nom) mm core ldentification - power core-2.20 colour rpct red, yellow & blue for power cores & green for earth core tensile strength before ageing n/mm2- min.4.20 % variation after ageing (air oven)- max. +-30% % variation after ageing in (air-bb)- max. +- 30%. elongation before ageing in % - min.200% % variation after ageing (air oven)- max. +- 30% % variation after ageing in (air-bb)- max. +- 30%. hot set test hot set elongation- 175% permanent set 15%. lnsulation resistance constant (min.) m ohm km. at 27deg.c- min. 3670 at 90 deg.c-min 3.67. thick of lnner sheath min 2.00 mm. rein forcement- open braid of textile material physical test on outer sheath thickness (nom) / min mm- 3.50/ 2.60 colour black, over all diameter of cable mm- 52.00+-3.00. tensile strength ) /bid number : gem/2025/b/6811700 * /dated: 24-10-2025 & & / bid document 1 / 22 before ageing n/mm2 - min. 11.0 at 2oo elongation 4n/ sq. mm. % variation after ageing in (air-bb)-max. +- 50% elongation before ageing in %- min.250% % variation after ageing in (air-bb)- max. + 50%. hot set test hot set elongation- max.175% permanent set- max 15. oil resistance test variation in % in tensile strength- max. +-40% variation in % in elongation-max. +-40%. tear resistance in n/mm - min.5.0. flammability test period of burning after removal of flame- max. 60 sec. min unaffected portion from the lower edge of the top clamp - min 50 mm. test high voltage at room temp- 10 kv ac for 4 hours. water absorption test increase in capacitance 1 to 14 days max- 6% 7 to 14 days max- 2.5%., control trailing cable 12 c x 2.5 3 p x 1.5 (pair screened) 2 voltage grade 1.1 kv 3 reference standard generally confirming to is: 9968 (part- 1)1998 4 conductor a. material to is:8130/84 annealed tinned copper b. nominal area of cross section(sq. mm) i)-unscreened core (sq. mm.) 2.5 ii) - screened pair (sq. mm.) 1.5 c. flexibility class as per is:8130/84 class-5 d. maximum dc resistance of conductor at 20 deg. c i)-unscreened core (ohms/km) 8.21 ii)- screened pair (ohms/km) 13.7 5 insulation i) material epr type ie-2 to is:6380/84 ii) nominal thickness (mm) 1.0 6 two cores of 1.5 sq. mm. size twisted together to form a pair yes. 7 individual pair screening each pair of 1.5 sq. mm. size taped with rpct, screened with 0.2 mm nom dia of annealed tinned copper wires braid, taped with melinex tape. yes. 8 no of cores / pair i)-unscreened cores 12 ii)-screened pairs 3 9 identification of power cores by number printing on cores. 10 laying up (i) three screened pairs laid up together, taped with rubber proofed cotton tape to form group as "a" (ii) 12 unscreened control cores laid up together around group as "a" of screened pairs and taped with rubber proofed cotton tape applied with open spiral. 11 inner sheath a) material to is: 6380/84 hd hofr csp type se-4 b) minimum thickness (mm) 1.6 12 an open braid of nylon cord reinforced in between inner and outer sheath. yes. 13 outer sheath a) material to is: 6380/84 hd hofr csp type se-4 b) nominal thickness (mm) 2.5 14 nom. overall diameter of cable (mm) 33.0 tolerance on nom. overall dia