Get complete information related to latest Precast Beam Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Precast Beam Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Precast Beam Tenders.
Tender For state scheme (nabard)/25-26/barsoi/01 - construction of hl rcc bridge from ganjan to vibhor hat road at ch.-1.720km, earthwork in excavation for structures as per drawing and technical specifications clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. i) upto 3m depth, providing and constructing temporary island 8 m diameter for construction of pile foundation. assuming depth of water 4.0 m and height of island 4.5 m., dismantling of reinforced concrete pile head complete as per drqwing and technical specification, providing and laying of pcc m15 levelling course 150mm thick below the pile cap. ii. pcc grade m-15 (levelling course), r.c.c. grade m 35 in pile foundation complete as per dwg & tech specification. pile cap in rcc m-35, bored cast-in-situ m35 grade r.c.c. pile excluding reinforcement complete as per drawing and technical specifications and removal of excavated earth with all lifts and lead upto 1000 m. ii. 1200 mm dia, supplying, fitting and placing hysd bar reinforcement in foundation complete as per drawings and technical specifications clauses 1000 and 1202, providing steel liner 6 mm thick as per detailed drawing., r.c.c. grade m-35 in substructure complete as per dwg & tech specification i) upto 5m height (using concrete mixer), r.c.c. grade m-35 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), r.c.c. grade m-40 in substructure complete as per dwg & tech specification ii) from 5m upto 10m height (using concrete mixer), supplying, fitting and placing hysd bar reinforcement (fe 500) in substructrue complete as per drawings and technical specification clauses 1002, 1005, 1010 & 1202, supplying, fitting and fixing in position true to line and level pot-ptfe bearing consisting of a metal piston supported by a disc or unreinforced elastomer confined within a metal cylinder, sealing rings, dust seals, ptfe surface sliding against stainless steel mating surface, completre assembly to be of cast steel/fabricated structural steel, metal and elastomer elements to be as per irc: 83 part-i & ii respectively and other parts conforming to bs: 5400, section 9.1 & 9.2 and clause 2006 of morth specifications complete asper drawing and approved technical specifications., providing weepholes in brick masonry/stone masonry, plain/reinforced concrete abutment, wing wall, return wall with 100 mm dia ac pipe extending through the full width of the structures with slope of 1(v):20(h) towards drawing face complete as per drawing and technical specification clauses 614, 709, 1204.3.7, backfilling behind abutment, wing wall and return wall complete as per drawings & technical specification clause 1204.3.8 i) sandy material, providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and technical specification clause 1204.3.8, providing and laying reinforced cement concrete in superstructure complete as per drawing and technical specifications clauses 800, 1205.4 and 1205.5 ii. rcc m-35, supplying, fitting and placing hysd bar reinforcement (fe 500) in superstructrue complete as per drawings and technical specification clauses 1002, 1010 & 1202, providing and laying cement concrete wearing course m30 grade including reinforcement complete as per drawing and technical specifications clauses 800 and 1206.3, provision of an reinforced cement concrete crash barrier at the bridge decks& approaches to bridge structures constructed with rein forced cement concrete with hysd r
Tender For bid to ras constr mod maint of 8 feet ditch of size 8 feet x 6 feet x 3 feet , constr mod maint of zig zag balance of size 19 feet 8 inch x 4 feet 18 inch x 5 ft , constr mod maint of confidence walk of size 25 feet x 8 feet x 10 feet , constr mod maint of w wall of size 22 feet 6 inch x 14 feet x 6 ft 3 inch , constr mod maint of obstacle ramp of size 18 feet x 16 feet 6 inch x 8 feet , constr mod maint of stepping stone of size 20 ft x 17 ft 6 inch x 8 ft nos 8 , constr mod maint of inclined wall of size 4 feet x 16 feet 6 inch x 5 feet , constr mod maint of in out vault of size 12 feet x 18 feet 5 inch x 3 feet 2 inch , constr mod maint of high balance of size 24 feet x 6 feet x 6 feet x 2 , constr mod maint of belly roller of size 17 feet 7 inch x 14 feet 7 inch x 4 feet , constr mod maint of clear jump of size 55 feet x 13 feet 7 inch x 2 feet , constr mod maint of gate vault of size 12 feet 4 inch x 6 inch x 5 feet 5 inch , constr mod maint of tarzan swing of size 25 feet x 21 feet 5 inch x 3 feet 5 inch , constr mod maint of leopard jump of size 9 feet x 11 feet 6 inch x 25 feet , constr mod maint of way bars of size 26 feet x 8 feet x 8 feet , constr mod maint of swing stop jump of size 20 feet x 12 feet x 25 feet , constr mod maint of burma bridge obstacle of size 42 feet x 42 feet x 12 feet , constr mod maint of crawl trench of size 66 feet x 20 feet x 1 feet 8 inch , constr mod maint of horizontal rope of size 31 feet x 27 feet x 17 feet 6 inch , constr mod maint of stage platform work of size 80 ft x 80 ft x 1 point 5 ft 02 nos , constr mod maint of urine point and 3 urine pot arrangements 02 nos , constr mod maint of toilet room of size 6 feet x 6 feet x 10 feet nos 1 , constr mod maint of rcc plinth nos 25 , constr mod maint of store room of size 10 feet x 10 feet x 10 feet , supply installation of rfid complete sys and electrical timer 100 nos , constr mod maint of drain cover of size 15 feet x 20 feet , constr mod maint of path way of size 2800 feet x 15 feet , brick work needs to be done comma the old one is broken and needs to be re masoned appx 525 sqft , the old plaster needs to be removed and new plaster needs to be laid sqft 5000 appx