Tender For bid to ras bid to ras corrigendum : supply of hpsu with its spares for singrauli project - hpsu with flushing device etc for turbine valves for singrauli unit-1 , hpsu with flushing device etc for turbine valves for singrauli unit-2 , main con trol fluid pump along with motor & coupling complete assembly , filter element along with o-rings/gaskets etc. for filter in main line , filter element along with o-rings/gaskets etc. for filter in regeneration circuit , molecular sieve and ion exchanger amberlyist including o rings gaskets etc , filter element along with o-rings/gaskets etc. for filter in cooling cum filtration circuit , pressure transmitter for main hpsu , level transmitter for main hpsu , rtd for main hpsu , pressure switch for main hpsu , differential pressure switch type 1 for main hpsu , differential pressure switch type 2 for main hpsu , differential pressure switch type 3 for main hpsu , proximity switch for main hpsu , pressure gauge type 1 for main hpsu , pressure gauge type 2 for main hpsu , pressure gauge type 3 for main hpsu , pressure gauge type 4 for main hpsu , permanday charges for training supervision during erection and commissioning , per visit charges for training supervision during erection and commissioning
Tender For supply of supply of consumables /implants /devices/accessories, on consignment basis for ctvs - ventilator, invasive pressure monitoring, iv drip sets, anticoagulation monitoring and airway consumables, bain circuit adultbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., bain circuit pediatricbased on mapleson "d" system, provided with a corrugated tube, expiratory valve and antistatic bag.should have co-axial modification of the basic "t"-piece system, developed to facilitate scavenging of waste gases.the process should include patient inspiring fresh gas from the outer reservoir tube and expiring into reservoir tube.lightweight anesthesia delivery system., corrugated tube connectorshould allow connection between all breathing circuits and the et tube connector.thecorrugatedtubeshouldbeexpandable.shouldallowmovementofbreathingcircuitatpatientend.should be made of medical grade pvc.should be compatible with ett and tracheostomy tube., micro aggregate blood filter for red cell transfusionfilter media should be 40 micron rated polyester screen media with uniform pore sizeshould have total filter surface area of 170 sq.cmshould have average capacity of filtering 10 units of blood., packed red cell & whole blood leucocyte reduction filters.bedside filtration of one & two unit of packed red blood cells or whole bloodshould have universal spike with microbiological recovery ventshould be with attached straight administration set/automatic self leveling drip chamberperformance should consistently average less than 2x105 residual leukocytes per unitred cell recovery should average greater than 90%.filter housing hold up volume should be 25ml for one unit filter and 35ml for two unit filterit should be single use, forced warming blanketshould be disposable and two layered; should consist of non woven propylene fabric for body warming. should be usable with forced air warming units. material should be latex free and should meet flammability standard 16 cpr 1610 for safety. the manufacturer must have all the below listed types of blankets and should quote the prices separately for separate blankets full body adult underbody adult with arm and head openings pediatric full body pediatric underbody blanket. should be compatible withcommon machines. should be ce certified, cuff inflator and pressure gauge itisusedtoinflate& preciselymonitorthecuffpressureofet tube, tracheostomy tube and lma cuff. reducetheriskofpressurenecrosisandmucosal ischemia theriskofaspirationcanbeavoidedeliminatestheuseofsyringestoinflate&deflatethecuffs. should have release valve to adjust the pressure. gaugecalibratedincmh2owiththedetachablelongconnecting tube. shouldhaveinflationbulbfortheinflationofthecuffshouldhavethehookatthebackoffitsintostandardrail.should have widely spaced scale markings with colour coded pressure ranges.ergonomiconehadoperation, intubation pillow reusable intubation pillow for head elevated laryngoscopy position (help) for airway management of obese &l arge framed patients. shouldbemadeupofdensefoam. shouldbesuppliedwithheadcradle shouldbevinylcovered shouldbecemarked, negative insipratory force meter should be disposable, compact, light weight & amp;single patient use negative inspiratory force meter to check the negative inspiratory force of the ventilated patients with the facility of memory indicator point ertore cord reset highest force achieved by the patient individually packed ready for use. shouldbe ,ce marked, capnography co2 sampling mask shouldhavetheprovisionforbreathtobreathmonitoringforboth nose & mouth should have the facility to deliver oxygen; allow sampling of exhaled carbon dio
Tender For corrigendum : supply and complete servicing/ overhauling & replacement of media and nozzle in side stream filters at sikka tps. - side stream filtration media- (quartz sand) for unit ssf tank, complete strainer/nozzel set (approx.1100) for unit ssf tank, bottem/ strainer plate (is:2062 gr.a 8mm thick) for unit ssf tank, work of replacement of filtration media ( quartz sand ) & strainer / nozzles., work of replacement of bottom/ strainer plate
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; power house equipment, electrical system or installation; service provider - maintenance and servicing of 315kva, 6kv/433v transformer at beml,kolkata site:top cover opening, change of top cover gasket, re-fixing with connection afterproper maintenance. oil leakage repairing ,change of all necessary gasket ifrequired, cleaning of all terminals etc. filtration of transformer oil .top up oftransformer oil as required. testing & commissioning of transformer and makeready for operation as per acceptable parameters.
Tender For supply of urine monitoring device , modular dilysis unit on turnkey basis , water filtration plant on tyrnkey basis at mira bhaynder , fully automated processor for gel cards , chemiluminescence immunoassay machine for blood bank , blood storage refrigerator 2 to 6 , domestic fridge 365 liter , deep fridge , tube sealer machine , ophthalmoscope , diathermy bipolar , blood gas analizer , c arm machine , non contact tonometer , ophthalmic microscope , phaco machine
Tender For corrigendum : supply of h.b.f spares> - wear belt (56850 x 50 x 6mm thk), scrapper blades 4.2mtrs hbf, curb of 125mm height (each meter), 4 numbers of end slides, buta seal (1mm thk x 29000mm), teflon strips (4200mm lg) (uhmwpe), spray nozzles (each), belt guide rollers, cloth trackig air bellows (1 set = 2 nos), plummer blocks for 110 sq.mm "uhmwpe"-1210ek with out bearing, plummer blocks "uhmwpe"-1209ek with out bearing, vacuum box lifting cylinder assembly, 4 nos ss304 clamps, air duct sleeve, 400 nb belt return rollers "msrl", feed dam roller msrl, 100 nb cloth return rollers, 150 nb cloth return rollers, cloth tension assembly, pneumatic panel, filtration hose along with 100mm x 2900mm length with 4nos ss304 clamps, filtration hose along with 100mm x 3000mm length with 4nos ss304 clamps, one set of seal strips s for 110 m2 hbf (one set consists of 18 pieces for the vaccum box, 1 piece at head end, 1 piece tai end, 4 pieces half moon at ends), slurry feeder hose for nuetral hbf flexible hose -274m id x 1850mm long with hose clamps to suite 250b pipe., slurry feeder hose for nuetral hbf flexible hose -169m id x 1800mm long with hose clamps to suite 150b pipe., bowed roller for horizontal belt filter of diameter 150mm (moc of shaft : ss316), axle diameter : 75mm.roller face : 4450mm, height of bow : 74mm, wear belt(56850 x 50 x9 mm thk), vacuum box (moc :ss304), vacuum box lifting leaver assembly(moc :ss304), spares of 5 m2 horizontal vaccum belt filter (model: 12b/02-30v product filter), cloth tensioner assembly, belt return rollers 250 nb, feed dam rollers 285 nb, cloth roller 75 dia, cloth tension roller 75 dia, cloth tracking roller 75 dia, belt guide roller m.k a ss304/hdpe, belt guide roller m.k b ss304/hdpe, belt guide roller m.k c ss304/hdpe, seal water assy-ss304, spray pipe assembly, spray sheet pvc, cloth tracking unit-ss304/nr bellows, pneumatic pannel/cloth sensor assy, spray pipe manifold, slurry feeder assy, curb 75mtrs ht (each meter), wear belts endless (6thk x 35 width, 12875 length), plummer blocks "uhmwpe"-1207ek with out bearing, cloth scrapper, plummer blocks 30 dia for scrapper "uhmwpe" with out bearing, feed dam roller bearing blocks with out bearing, filtrate hoses along with hose id 75 x 1750mm long with 4 nos of ss316 clamps, seal strip sets consistes of 4 nos of seal strip, 1 no. head end pad, 1 no. tail end pad, and 4 nos of end slides