Get complete information related to latest Primer Coating Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Primer Coating Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Primer Coating Tenders.
Tender For : roof mounted ac package unit (rmpu) for lhb eog ac coaches in coach sets consisting of rmpu(with r-407c refrigerant)-02 nos. and microprocessor controller unit -1 no., with supply of bellows set consisting of01 no. supply air bellow, 02 nos fresh air bellows & 02 nos. return air bellows ducts made of meta aramid/ paraaramid fabric with silicon rubber coating on both sides to spec. no. rdso/pe/spec/ac/0197-2020 (rev-0), rmpuas per specification no rdso/pe/spec/ac/0061-2005, rev-1, type-i & microprocessor controller unit tordso/pe/spec/ac/0139-2009, rev-1, complete with accessories, as per scope of supply as in the rdsospecification.rdso item id: 3100018
Tender For supply of hex head screw m16 x 50-10.9(ht) to specn. no.is:1364(pt.2)/2023 is:1367(pt.3)/2017 ce coating as per rcf/mdts-057 rev. nil. item should be procured from rdso approved sources of axle end high tensile cap screws [ warranty period: 48 months after the date of delivery ]
Tender For supply of hex head screw m12x25, as per drawing: is:1364(part-2)-2002,5.6, ce coating as per mdts-057, packing instruction-pi042. it should be ensured that item should not rub during transportation. make :- tvs / tuff / dfl / unbrako .
Tender For provision of external electric supply for 661 sailors inliving accommodation at visakhapatnam - supply, installation, testing and commissioning of outdoor type step down transformer 1000 kva 11kv/433v dyn11 oil filled (onan) distribution transformer double copper wound with radiator wall with conservator tank & porcelain bushing for ht, lt with off circuit tap changer, marshalling box all as per is 1180 (part-1) : 2014, bee certified, energy efficiency level ii (as per latest ammendment no 4) complete as directed., a) off circuit tap changer (octc), tapping range +5% to -10% in a steps of 2.5% per step (7 positions)b) temp. rise shall be 40/45 deg. c for oil/winding resp. over an ambient of 50deg.c tempc) insulation class: ad) losses ( subject to is 1180 efficiency level 2/ star 2 as per latest amendment 4) max. total loss @ 50% loading: 2620 w and max. total loss at 100% loading: 7000 w.e) % impedance (%z) shall be 5.00% (subject to is tol.)f) rating & diagram (r&d) plate (fitted on transformer)g) oil temp. indicator (oti) with alarm and trip contacth) winding temp. indicator (wti) with alarm and trip contactj) rated temp class of transformer compartment k10 upto 1000kvak) lifting lugs/ hooks for transformer.l) oil filling inlet pipe with plug.m) air release valve and drain out pipe with plug.n) conservator tank with level guage.o) silica gel breatherp) first oil fill up to recommended level by manufacturer with new oil as per is 335.q) cable terminal boxes with bushes on both ht and lt sides.r) hv winding: delta & lv winding: star.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply and fixing main lt panel cpri approved made out of crca sheet 3.15 mm thick outdoor pedestal type totally enclosed with front and rear opening, hinged doors with projected an raised platform of suitable size, weather and water proof with necessary locking arrangements along with lugs, cable glands of various sizes for cables, danger notice plate, strickering of switcher gear about termination of switch gear, and the nuts/ bolts etc used are to be made of rust proof material incl as per al bus bar rated with insulators suitable for three phase and four wire lt ac, 50 hz 415 v 2000 a capacity complete with powder coating, necessary internal electric connection as required and provision of the following : (main lt panel)., incoming:air circuit breaker 1600 amps, 50 ka, mdo type, 4 pole, micro processor release, with adjustable type overload protection, short circuit protection, with necessary cts, meters and cable boxes. - 1 no.outgoing:a) mccb 250 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 07 no (bldg vtpn 02 nos, bldg panels 04 nos + spare)b) mccb 140 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (dg amf panel)c) mccb 160 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (ff panel)d) mccb 100 amps, 25 ka, 4 pole, suitable for capacitive loads, thermal magnetic release, with adjustable type overload protection, short circuit protection - 01 no (apfc panel)e) intelligent panel meter to measure voltage, current, frequency, power factor, kwh etc with all connected cts.f) led indicating lamps with colour red, yellow, blue of 03 sets.note: civil work for the construction of foundation including necessary earthwork etc is deemed to be included in quoted rates of the item., supply & fixing of perforated gi cable tray of size 150 mm width x 50mm depth x 1.6mm thickness with perforations not more than 17.5% in convenient sections, joined with connectors, suspended from the ceiling with gi suspenders including bolts & nuts etc as req
Tender For supply of corona resistant copper wire for repair shop d d - item 10 , item 20 , item 30 , item 40 , item 50 electrical wire type : corona resistant material : copper dimension : 1.25mm additional information : is:13730 triple coated corona resistant wire for vfd controlled motor base material : copper insulation coating :- base coat poly etserimide + middle coat corona resistant +top coat polyamide- imide, class temp- 220 c.material: special metal oxide filled enameled copper conductor. the insulation covering thickness may be complied as per grade 2 specification of indian standard is 13730. dimension :- 1.25mm surface :- smooth breakdown voltage :- 5 kv insulation class :- c maximum working temp :- 200 degree centigrade specification value :- is-13730, part-13, grade -2 electrical wire type : corona resistant material : copper dimension : 1.25mm additional information : is:13730 triple coated corona resistant wire for vfd controlled motor base material : copper insulation coating :- base coat poly etserimide + middle coat corona resistant +top coat polyamide- imide, class temp- 220 c.material: special metal oxide filled enameled copper conductor. the insulation covering thickness may be complied as per grade 2 specification of indian standard is 13730. dimension :- 1.25mm surface :- smooth breakdown voltage :- 5 kv insulation class :- c maximum working temp :- 200 degree centigrade specification value :- is-13730, part-13, grade -2, electrical wire type : corona resistant material : copper dimension : 1.0mm additional information : is:13730 triple coated corona resistant wire for ) /bid number : gem/2025/b/6606108 * /dated: 30-08-2025 & & / bid document 1 / 17
Tender For corrigendum : supply of web welded with top plate as per drawing no le11317 alt a & le11319 alt a with welding a s per rdso guidelines for irsm-41 and with red oxide zinc chromate primercoating [ warranty period: 30 months after the date of delivery ]
Tender For supply of [hex head screw m16x120 high tensile as per is:1364 (part-2) -2002, ce-with property class-10.9 to is-1367(part-3)-2002, coating as per mdts-057. and the item should be procured as per rdso l. no. ? mc/ctrb/genl., dated- 10/12/24.]
Tender For lws shell complete (a) one coach set of roof, 2 mm sidewall and end wall 1) roof assembly to drg no 58116032, alt 'l'- 1 no. welding pin to be assembled as per drg no 58110037, alt 'nil' (with latest sub drawing49516008, alt "a") 2) end roof assembly to drg no 58116066, alt "g"- 2 nos. 3) sidewall to drg no 75214023,alt "nil"- 1 no. 3mm thick to rdso spec. c k-201 x2crni12 sheet to be used for manufacturing sidewall sheet instead of 2mm sheet. 4) end wall to drg no 74115001, alt "h"- 2 nos. (b) partition frames & body shell items and floor supports 1) 75210012, alt "nil"- 1 no. 2) 75210002, alt "nil"- 1 no. 3) 58210036, alt "a"- 2 nos. 4) 75210003, alt"nil"- 1 no. 5) 67010011, alt "a"- 2 nos. 6) aaa10488, alt "c"- 6 nos. 7) 58110017, alt "b"- 2 nos. 8) 58110015, alt "a"- 6 nos. 9) 58110016, alt "a"- 3 nos. 10)aab10338, alt "nil"- 16 nos. (c) under frame complete to drg.no.67011001, alt 'n'- 1 no. the firm shall fulfill the manufacturing requirement of icf/md/spec-451, issue status-01, rev-01. assembly of (a), (b) and (c) shall be done as per drg no. 75210001, alt 'b' (d) installationitems 1) body side entrance door installation as per drg no. -58152001, alt "b" -1 no. 2) foot step complete to drg no. 58124004 alt "nil"-6 nos. 3) exterior garniture to drg no. 59326001 col-i alt "h" -1no. 4) application of epoxy coating. 46590003 col-1 alt "d" -1 no. 5) roof ventilator assly -01873401 col-i alt"r" - 7 nos. 6) coupler mounting -46021001 col-i alt "e" (aar h coupler to pl no. 33549771 -2 nos and anti-rotational channel to pl no.-33544402 -1 no as free supply). for installation items (d) general installation drg no. 75290002, alt 'id' to be followed. special condition : suitable packing should be done to prevent damage during transit and unloading. installation required as per assy.drg.& annexure-a, dtd 13-09-2023 to be followed. supply rates and installation rates to be quoted separately. [safety item ]