Web Analytics Made Easy - StatCounter

Probe Tenders

Get complete information related to latest Probe Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Probe Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Probe Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :40849714 Due date: 30 Jun, 202530 Jun, 2025 NA
Tender For supply of probe cleaner for 5-part councell panta 2.0

Central Government / Public Sector

CTN :40825578 Due date: 08 Jul, 202508 Jul, 2025 NA
Tender For supply of so2 analyzer , nox analyzer for online stack monitoring , out of stack dilution probe , zero air generator , umbilical cord

State Government

CTN :40398381 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For corrigendum : empanelment of agencies for supply of laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoridemeter: ph/ise benchtop meter with electrode stable, universal power adapter, literature, pc cable, meter test certificate electrode: ionplus fluoride and nitrate combination ion selective electrode, 1m cable, waterproof bnc benchtop ion meter (ise) along with fluoride, nitrate #electrode range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 relative accuracy 0.002 calibration points up to 5 calibration editing yes #mv/ rmv orp range 2500.0 mv resolution 0.1 relative accuracy 0.2 mv or 0.05 % of reading whichever is greater eh orp mode yes ise range 0 to 19999 resolution up to 3 significant digits relative accuracy 0.2 mv or 0.05 % of reading whichever is greater units ppm, m, mg/l, %, ppb, none calibration points up to 5 calibration editing yes calibration features timed end point, linear point to point, non-linear selectable auto-blank, low concentration range stability #temperature range -5 to 105 c, 23 to 221 f resolution 0.1 relative accuracy 0.1 offset calibration 1-point datalogging memory 2000 with time and date stamp log function manual, ready (include auto-read ), timed log edit delete individual points, group of points or all inputs ph electrode bnc, reference pin atc probe 8-pin mini-din #output rs232, usb power ac adapter included universal, 100-240 vac battery power optional 4 aas battery life 800 hrs, fluoride electrode of ion metersame make that of the ion meter, manifold filtration assembly* wide range of pumps and filtration flasks * high quality components * easily exchangeable elements *maintenance-free * low noise * added filters for enhanced pump longevity * filtration base with silicon stopper, cap & aluminium clamp connecting silicon tube technical specification for filtration flask set # high-pressure resistant tube # fiberglass filter membranes (47mm / 0.1 m) # ptfe disc filter #normal liquid filtration * specification for filtration glass set #suction bottle capacity(ml) 1000 ml # filter diameter(mm) 47/50 mm # * specification for filter flask * material: statinless steel 304, capacity: 300 ml (100 ml each) [ unit should consist of 3 flask so that 3 sample can be filtered simultanelously without any issue] # effective filtration area(cm2) = 9.6 cm2, outlet connector(mm) = 8 mm * specification for vaccum flask: #flow rate of the pump(l/min) = 17 l/minultimate vacuum(mbar) = 150 mbar # oil free, maintainance free, built in thermal protection to shut off when over heated., auto cut heater for distill water plant so that when water level decreases the heater is switch off automatically, voltage stabilizer capacity- 3 kva servo stabilizer 5 star rating, heating mantle (single station) should have digital energy regulator with multiple step power regulation automatic spill detection and saftey shutdown in built precision temperature control technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 420 degree celcius. accuracy: plus minus 1.0 degree celcius, power consumption : 150 w, heating mantle (combined unit) material of construction heating block: made with grade epoxy painted chemical resistant coating, aluminum block with 6 thermo wells for processing 6 different samples at a time. #racks: ss 316 # glassware: teflon coated # temperature range ambient + 10 deg c to 450 deg c # stability of temperature better than 0.5 deg c # controller consist of digital read out of temperature and time with 4 programmable ramps for each method. # number of programmable methods 20 numbers. # heating powers 1000w # heating position minimum 6 position # digestion time range -1 to 999 minutes # the system should have facility of acoustic signal at the end of completion of cycle to notify the operator. # the thermal digestion unit should have high thermal homogeneity # the setup should have small f

Central Government/Public Sector

CTN :40229542 Due date: 26 Jun, 202526 Jun, 2025 NA
Tender For bid to ras bid to ras bid to ras bid to ras corrigendum : supply of azithromycin disc (15? g) , ceftazidime disc (30? g) , ceftriaxone disc (30? g) , ciprofloxacin disc (5? g) , clindamycin disc (2? g) , co-trimoxazole disc (25? g) , erythromycin disc (15? g) , gentamicin disc (10? g) , gentamicin disc (120? g) , levofloxacin disc (5? g) , minocycline disc (30? g) , streptomycin disc (300? g) , imipenem-edta disc (10-750? g) , cefoxitin-cloxacillin disc (30-200? g) , oxidase disc , amikacin disc (30? g) , ampicilin/sulbactam disc (20? g(10/10? g) , ampicillin disc (10? g) , aztreonam disc (30? g) , cefepime disc (30? g) , cefotaxime disc (30? g) , cefoxitin disc (30? g , ceftazidine avibactam disc (30/20? g) , cefuroxime disc (30? g) , linezolid disc (30? g) , meropenem disc (10? g) , nitrofurantoin disc (30? g) , tetracycline disc (30? g) , vancomycin disc (30? g) , ertapenem disc (10? g) , imipenem disc (10? g) , piperacillin-tazobactam disc (100/10? g) , ceftazidime/clavulanic acid disc (30/10? g) , brain heart infusion agar , brain heart infusion broth (blood culture bottle) (adult 70 ml) , brain heart infusion broth (blood culture bottle) (paediatric 20 ml) , antisera- shigella dysenteriae poly a , antisera-shigella dysenteriae poly a1 , antisera-shigella flexneri poly b , antisera- shigella sonnei , total and direct bilirubin estimation kit based on diazotized sulphanilic acid method. , sterilization indicator- chemical autoclave tape

Central Government/Public Sector

CTN :40842519 Due date: 05 Jul, 202505 Jul, 2025 NA
Tender For supply of oxt4cdr explo-proof oxymeter 18" probe for oxt4c oxygen analyser, make: emerson, part no. : oxt4cdr-1,remote mounted oxymitter electronics for oxt4c oxygen analyser,zirconia cell replacement kit for oxt4c oxygen analyser, ansi 18" - hazardous area, make: emerson, p

Central Government/Public Sector

CTN :40825071 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of laboratory items - fluoride ion selective electrode package for ion meter , e coli and coliform , nitrate ion selective electrode package for ion meter , dissolved oxygen probe , mel mpn total coliform and e coli test kit

Central Government/Public Sector

CTN :40827305 Due date: 04 Jul, 202504 Jul, 2025 NA
Tender For supply of traditional architecture type in-situ zirconium oxide probe , rosemount 6888xi oxygen transmitter

CTN :40507382 Due date: 01 Jul, 202501 Jul, 2025 NA
Tender For corrigendum : supply of probe insert holder diameter 8 mm, length-400 mm ta-ih- 127 for v7 model trimos make 2d height gauge. , perpendicularity probe ta-ms-101 for v7 model trimos make 2d height gauge.

CTN :40826669 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For supply of spo2 probe , humidifier bottle , bactria filter , patient lead , chest electrode , limb electrode , on off switch spst 16a , on off switch spst 4 a , toggle switch dpdt , cap 33 uf , ic 7808 7805 7812 , ntc 10 d 20 , 2 core wire , fuse 5a , fuse 10a

Central Government/Public Sector

CTN :40837804 Due date: 10 Jul, 202510 Jul, 2025 NA
Tender For supply of spring for probe assembly for paras make 09 channel b-scan srt 2011b [ warranty period: 30 months after the date of delivery ]
 Loading, Please wait...

Connect us via What's Up