Tender For empanelment of agencies for supply of different laboratory instruments for various water testing laboratories under jal jeevan mission, assam - ion meter with electrode and accessories for fluoride & nitratemeter: ph/ion/ mv-redox-orp/ temperature benchtop meter with electrode for testing both fluoride & nitrate separately in water samples. technical specification: ph range: -2.000 to 20.000 resolution 0.1, 0.01, 0.001 accuracy 0.002 ph + 1 lsd calibration points up to 5 buffer sets: usa/ nist/ din/ custom orp range 2000.0 mv rel. mv range 2000.0 mv accuracy 0.2 mv resolution 0.1 mv ion concentration 0.001 to 19999 ppm resolution up to 3 digits relative accuracy 0.5 % full scale (monovalent) and 1 % full scale (divalent) calibration points up to 8 temperature range 0 to 100 c, 32 to 212 f resolution 0.1 accuracy 0.3 c/ 0.5 f compensation: auromatic temperature correction other requirement: auto buffer recognition, memory 500 with time and date stamp rs 232 alarm for calibration due & out of range alurm auto logging function., fluoride electrode of ion metersame make that of the ion meter, nitrate electrode of ion metersame make that of the ion meter, manifold filtration assembly (to be used for micobiological test)* sturdy and easy to clean ss filtration assembly with funnel, manifold unit, air vent filter and vaccum pump ready to be used for mictobiological testing * specification: # funnel with inbuilt clamp: made of ss 316, capacity: 300 ml, ss filter support base, ss support screan: 47 mm, made of ss 316l; filtration area 9.6 cm2; silicon stopper: size 8, with silicon lid and silicon o ring. # filtration manifold: 3 place manifold, made of ss 316, valves made of ptee, connection 12 mm; suitable for both pp and ss funnel with rubber stopper fittings. # vacuum pump: oil free, piston powered, suitable to be used with 3 possition manifold; max flow rate: 34 l/ min; vaccum stage: double. max vaccum: 100 mbar. the vaccum pump should also have a vacuum suction bottle to protect the pumps componennt by preventing liquid or solid material from entering the pump during filtration process., voltage stabilizer (3 phase)# capacity- 3 kva # input voltage range: 295 v - 465 v normal range # output voltage range 380 v / 400 v / 415 v # output regulation: 1 %; # output settability: 380 v - 420 v; # frequency: 47 hz - 53 hz; correction rate: 70 v/ sec; # aircooled servo stabilizer, three phase., heating mantle (single station) should have safety cut off with precise heating for boiling, evaporation, distillation or extraction process technial specification: flask capacity 250 ml, working temp range: ambiant + 5 to 350 degree celcius. accuracy: 1.0 degree celcius, display: led display with temperature, time; construction material: ms; power consumption : 150 w, semi automatic digestor for cod analysis with all assssories material of construction epoxy painted with chemical resistant coating; temperature range ambient to 450 deg c # stability of temperature 0.5 deg c # temperature calibration - automatic; selectable ramp: upto 4 per program; digestion time range: 1 to 999 minutes; time selection: 1 minutes steps; countdown: digital readout; heating places - 6 possition; size of tubes: 250 ml test tubes (42 mm); power 1000 w; number of programmable methods 20 numbers. # the thermal digestion unit should have high thermal homogeneity # the setup should have small footprint., digital thermometer with probe# mini lcd thermometer # type: digital, # sensor cable length: 1 meter water proof probe # batteries: 2 x batteries should be included, # temperature range: - 50 - 110 oc, # temperature measurement accuracy: 1 0c, micropippete stand#self-standing holder accommodates most major brands of pipettes. #material: pmma, # capacity: 5 pipptes/stand, conical flask draining rack#material: acrylonitrile-butadiene-styrene/polycarbonate, # no. of pegs: 20
Tender For bid to ras corrigendum : supply of customized work benches and storage systems f f - vertical storage , wall , island , wall mounting , computer , technical drawing analysis , sitting , aluminium frame with glass
Tender For corrigendum : hiring of knowledge partner for gap analysis of pngrb technical regulations vis a vis international regulations, codes, standards and best practices
Tender For corrigendum : request for proposal for selection of technical consultancy services for validation and scrutiny of estimates and the cost analysis for projects undertaken by the government of chhattisgarh.
Tender For supply, installation, commissioning & testing of microprocessor based gas chromatograph for dissolved gas analysis as per technical specification attached.
Tender For empanelment of consultant/experts for various renewable energy relatedworks like technical due diligence, conducting energy audit as well as energyand o&m contact bill verification, re potential analysis (wind/solar), otherdesktop studies for re projects, regulatory policy compliance review, carboncredit advisory etc.
Tender For tender for supply of supply of amc of turbogenrator e e - capacitance and tan delta test on stator winding of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of partial discharge test pd on stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of stator core imperfection detection elcid test for 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of wedge tightness test for stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of natural frequency test for stator of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of polarization - depolarization current analysis on stator winding of 235mwe turbogenerator refer detail scope of work in attached technical specification. , supply of digital repetitive surge oscillograph rso test on rotor winding of 235mwe turbogenerator refer detail scope of work in attached technical specification.