Get complete information related to latest Pulse Generator Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pulse Generator Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pulse Generator Tenders.
Tender For supply of aoh kit for pulsegenerator speedometer of m/s autometer alliance ltd. part no. 1900007200/01 consisting 5 items as per annexure-a.
Tender For corrigendum : purchase of various testing advanced apparatus (lab equipment) in quality control labs under zone bharatpur, jaipur-i and jaipur-ii, jodhpur-i and jodhpur-ii, kota and tonk. - ultra sonic pulse velocity testing instrument :-supplying ultra sonic pulse velocity testing instrument for non destructive testing (ndt) of hardened concrete to asses the quality of concrete in term of dense, homogeneity and uniformity. instrument shall also be capable of crack & void detection and elastic properties measurment of concrete. the apparatus for ultra sonic pulse velocity measurment shall consist electrical pulsegenerator, transducers in one pair, standard calibrator bar, amplifier, electronic timing device. performance requirement of apparatus shall be as under :-- transit time accuracy within - 1 % range- range of time - 20 s to 10 ms- referance specimen - two no. usually steel bars having pulse transit time 25 s to 100 ms with accuracy 0.2 s- transducer - one pair - piezo electric and magneto strictime type frequencies in between 10khz to 200 khz, contact type ultra sonic concrete tester range - upto 5 mtr. & 5 mtr. and aboveaccuracy - 100 nano second, power - 7.2 v (dc), rechargable bettary - oper. temperature - 0 to 500 c - resolution - 0.1 s- display - 128x64 graphic lcd - display response time - instantaneousstandard accessories :-1- 1 set of 7.2 v nicd cell2- probe cable 2 no. (4m each)3- transduces - 2 no. (50 mm dia, 60 khz)4- calibration block alongwith verification block with nabl traceability certificate5- cover /bag instrument shall meet requirements of is: 516(part-5/sec.-i) 2018, en 12504-1 & astm c 597. standards.the complete item shall be supplied as per direction of engineer in charge . rates are inlusive of all taxes ., rotational viscometer : supplying & installation of rotational viscometer of spring torque model for higher viscosities that specially designed for conducting high-temperature testing of ashphalt binders in compliance with astmd 4402/d4402m-23 and is: 73-2013,is :15462-2019 & is:17079-2019 .standards . it should be capable to determine viscosities of liquids. like oil, ashphalt & solvent etc.key feature of apparatus shall be as under :-precise temperatures control unit to ensure precise temp control and maintaining content & accurate testing temperatures.user friendly inter face to easy to use and display of accurate result.level indicators surface level indictors should be our both the temp control unit and the main unit to ensure equipment remain level., versatile spindle options capable of with standing the demanding condition of ashphalt testing., builtin micro printer for convenient result printing., automatic range calculation capable of automatic full scale range (fsr) calculation for 100 % viscosity with specific spindle and speed combination., window based software shall include window based software for creating viscometer vs temperatures course with test data continently stored ms excel., high-visibility lcb the lcb display features a white backlight for enhanced visibility and clarity.technical specifications of apparatus shall be as under :-rotation speed 0.1- 250 rpm, viscosity measurement range 100 cp to 64m cp, torque range high up to 57496 dyne.cm ( 5.749 mn.m) ,, spindles set of large spindles as required, torque range 10%- 100% full -scale torque, measurement error: 1% (f s), temperature controlling range: up to 200 c, temperature controlling accuracy: 0.1 c, cubage of sample cylinder: 20ml, serial interface: rs232, working environment: ambient temperature: 15 c to 35 c, 85%, operating voltage: ac (220v 10%)v, 50hz, single phase, total power consumption: 200w, components included of apparatus shall be as under :- -head of viscometer -auxiliary controlling case (containing a temperature controller and a micro-printer), - thermo-electric heater, -spindles made of aisi 316l as per requirment with adaptor, -pen drive for pc software setupstand, ext
Tender For technical specification point wise dbs implant & accessories - dbs rechargeable with directional lead with25yr battery life & image guided programming integrated inside clinician programmer with micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers, usfda & ce approved kit contents: rechargeable pulsegenerator-1 , directional lead kit -2 , extension kit -2 , burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1, patient charging kit -1 , dbs rechargeable with non directional lead with 25yr battery life & image guided programming integrated inside clinician programmer micc multiple independent current control technology with zero volt technology,bluetooth connectivity with clinician and patient programmers. have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage, usfda & ce approved kit contents:rechargeable pulsegenerator -1, non-directional lead kit -2, extension kit -2, burr hole locking kit -2, tunneling tool -1, patient remote control kit -1, patient charging kit -1, dbs non rechargeable with directional lead with image guided programming integrated inside clinician programmer micc multiple independent current control technology &bluetooth connectivity with clinician and patient programmers,usfda & ce approved kit contents: non-rechargeable pulsegenerator -1 , directional lead kit -2 , extension kit -2, burr hole locking kit -2 , tunneling tool -1 , patient remote control kit -1,), dbs non rechargeable with non-directional lead with image guided programming integrated inside clinician programmermicc multiple independent current control technology withbluetooth connectivity with clinician and patient programmers. should have 8 contact non-directional lead kit with array span of 15.5mm for maximum coverage,usfda & ce approved kit contents: non-rechargeable pulsegenerator -1, non-directional lead 1), dbs implant kit with non-rechargeable, 3t mri compatible and sensing enabled ipg and directional leads.the implanted pulsegenerator (dbs neurostimulator- ipg) should have a minimum service life of 5-7 years and there should not be a need to recharge it periodically.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the leads should be able to stimulate in specific directions, in addition to the ability to stimulate circumferentially. markers on leads should facilitate directional programming even if lead rotates. the leads should also be able to sense lfps.burrhole kit should be there for securing lead in place. microelectrodes for intra op stimulation and recording should be there.the extension connecting the lead and ipg should be flexiblethere should be a tunneller to place the extension wire and the tunneller should be metallic and firm to enable smooth tunnelling.the system should have approval for conditional full-body 1.5t & 3t mri compatibility.patient programmer, enabling the patient to see and if needed, modify the stimulation under guidance, should be available. patients should be able to mark dyskinesia, tremor etc. using the programmer., dbs implant kit with rechargeable, 1.5t & 3t mri compatible and sensing enabled ipg and directional leads.the implantable pulsegenerator (dbs neurostimulator- ipg) should have a service life of 15+ years if regularly recharged by the patient at specified intervals.ipg should have the capability for group programming and ability to store the programming data in ipg itself and retrieve from ipg.the system should be able to sense local field potentials (lfps) from brain targets and this data should be accessible through the physician programmer. the system should have fda ap
Tender For supply of drive shaft for aal make pulsegenerator to part no. 5.8600.505. set consists of 2 items for aal make pulsegenerator 1) oil seal dia 20/40 x 6, to part no - 8.3010.138/01, qty - 01 no/set. 2) counter sunk screw m5 x 10 to part no 8.1211.404/14, qty - 01 no/set.deep groove ball bearing 6002 - 2z to aal part aal part no. 1910016300.o ring 39/42 x1.5mm for aal make pulsegenerator to part no. 8.3010.503
Tender For supply of pulse probe comb for aal make pulsegenerator aal part no. 5.8600.120/31. [ warranty period: 30 months after the date of delivery ]
Tender For supply of pulse probe comb for aal make pulsegenerator aal part no. 5.8600.120/31. [ warrant y period: 30 months after the date of delivery ]