Web Analytics Made Easy - StatCounter

Push Cutton Tenders

Get complete information related to latest Push Cutton Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Push Cutton Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Push Cutton Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :39665856 Due date: 19 Mar, 202519 Mar, 2025 NA
Tender For procurement of various electric items for installation in ac 16 tri nagar - s/o changeover switch fuse unit 4 pole with rewireable fuse with current capacity 63 amp. 415 volt, 50hz, make-l&t/havells/hpl/bch/c&s, s/o changeover switch fuse unit 4 pole with rewireable fuse with current capacity 100 amp. 415 volt, 50hz, make-l&t/havells/hpl/bch/c&s, s/o changeover switch fuse unit 4 pole with rewireable fuse with current capacity 200 amp. 415 volt, 50hz, make-l&t/havells/hpl/bch/c&s, s/o changeover switch fuse unit 4 pole with rewireable fuse with current capacity 400 amp. 415 volt, 50hz, make-l&t/havells/hpl/bch/c&s

Central Government/Public Sector

CTN :39715633 Due date: 10 Apr, 202510 Apr, 2025 NA
Tender For supply of cartridge + 130degree c, suitable for esti switch of lhb variant ac coaches of roof mo unted ac package unit, conf. to rdso spec. no. rdso/pe/spec/ac/0061-2005 rev -1. [ warranty per iod: 30 months after the date of delivery ]

State Government

CTN :39716431 Due date: 24 Mar, 202524 Mar, 2025 3.02 Lacs
Tender For replacement of switch disconnector fuse (sdf) unit with necessary hrc fuse replacement of spare coils of by-pass contactor along with some tit bit allied works at naihati booster pumping station

Central Government/Public Sector

CTN :39715701 Due date: 07 Apr, 202507 Apr, 2025 NA
Tender For supply of shunt safe device specification 1. the unit should be an audio visible alarm unit, to be u sed by the shunting staff for their own safety during shunting operations. 2. the unit should be made of at l east 1.2 mm thick ms sheet duly powder epoxy coasted. 3. the visible indication is to be provided with the help of a matrix of blue led?s of 5 mm diameter. the front size matrix should be have 4 rows and 4 column s and the matrices on either side should have 1 column of 4 led?s each. the led?s should be flashing with one second off and one second on times. the side led?s should be located at an angle of 32 to 35 degrees from the front matrix, with the objective is to disperse the light in the front, as well as on the two sides. 4. t he audio alarm should comprise of a loud speaker of such intensity as to be audible from a distance of at le ast 75 meters in a noisy environment. nominal audio power out put of the unit should be 10 watt, which sh ould be provided by the means of the sturdy horn type loud speaker. the horn should be protected with the help of ms bracket of suitable size duly powder coated. the sound to be intermittent to be decided in consu ltation with railways. 5. the unit should be provided with a battery backup of at least 4 to 5 hours. 6. batte r 12v 4.5 ah lithium-ion battery. 7. the unit shall be usable in all weather conditions in open areas. the de sign should be rainwater proof. 8. there should be hook for hanging the device with the coach/wagon. the hook should have a diameter of 2.5 inches and it should be possible to rotate the hook in any direction. hoo k should be strong enough tom sustain the regular used of the unit. 9. rubber lining or any other type of sh ock absorbers should be provided at the bottom and the back side. 10. the unit should be provided with a s uitable and sturdy on off switch, so located that it is not operated accidentally. a jack plug in arrangement should be provided to facilitate the changing of batter with an external charger. 11. the led?s should be pr otected with the help of an acrylic sheet. 12. battery on charge indication should be provided at suitable lo cation. 13. external smps charger to be provided for charging batteries. [ warranty period: 30 months af ter the date of delivery ]

corporations/Associations/Others

CTN :39709748 Due date: 28 Mar, 202528 Mar, 2025 NA
Tender For mtps i m ii oahs fam pdfacs unit ii attending annual overhauling works in plc switch gear panels modules breakers transformers pdfacs equipments and related accessories overhauling of mixing apparatus by dismantling cleaning painting and reassem

corporations/Associations/Others

CTN :39721571 Due date: 02 Apr, 202502 Apr, 2025 NA
Tender For mtps i m ii oahs fam pdfacs unit iv attending annual overhauling works in plc switch gear panels modules breakers transformers pdfacs equipments and related accessories overhauling of mixing apparatus by dismantling cleaning painting and reassem

corporations/Associations/Others

CTN :39721592 Due date: 02 Apr, 202502 Apr, 2025 NA
Tender For mtps i m ii oahs fam pdfacs unit iii attending annual overhauling works in plc switch gear panels modules breakers transformers pdfacs equipments and related accessories overhauling of mixing apparatus by dismantling cleaning painting and reasse

Central Government/Public Sector

CTN :39730505 Due date: 28 Mar, 202528 Mar, 2025 NA
Tender For supply of switch point shifting unit

Central Government/Public Sector

CTN :39706833 Due date: 25 Mar, 202525 Mar, 2025 NA
Tender For supply of 4203077683 switch point shifting unit, hs12d03-ii

Central Government/Public Sector

CTN :39711510 Due date: 26 Mar, 202526 Mar, 2025 15.32 Lacs
Tender For tender for supply of shunt trip coil assembly , part no.v0021 , electrical release coil assly , , part no.v0022 , fail safe relay , part no.p0068 , ammeter , part no.fsv00104 , voltmeter , part no.fsv00105 , push to trip assy , part no.v0042 , operating mechanism , part no.om009 , vacuum interrupter , part no.v0048 , vacuum circuit braker assly. vcb9576 , part no.vfs0062 , indicating lamp , part no.p0043 , ammeter voltmeter selection switch , part no.p0046 , earth leakage relay test reset switch , part no.p0047 , rectifier capacitor unit , part no.p0048 , auxiliary contactor 110 vac , part no.p0061 , fuse base and carrier , part no.fsv00117 , breaker charging handle , part no.v0030 , push button switch , part no.p0044 , control fuse 2-10a , part no.fsv00116 , potential transformer single phase 3.3kv 110v ac , part no.p0056c , earth leakage relay , part no.p0049
 Loading, Please wait...

Connect us via What's Up