Web Analytics Made Easy - StatCounter

Pvc Ducting Tenders

Get complete information related to latest Pvc Ducting Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pvc Ducting Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pvc Ducting Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :42063030 Due date: 06 Oct, 202506 Oct, 2025 1.00 Crore
Tender For supply of electric slaughterhouse (for animals) - primary & secondary chamber primary chamber* single chmber furnace of size 4270 mm x 1980 mm x 1820 mm.* plate thickness- 5 to 8 mm.* lining of interior of furnace- 400 mm wall cermaic blanketk, high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006* operation temperature- 800o c to 1000o c.* top smoke discharge for secondary chamber.* ash removal doors to be provided for ash collection after combustion.* ingtion- automatic.* temperature control- automatic* material loading- front gate- automaticsecondary chamber* operating temperature - 1050o c to 1250o c.* material of construction- mild steel with high aluminia refractory brick is-8-1994 line with insulation brick is 2042-2006.* made from is 2062 grade mild steel materials (or better) duty lined with insulation bricks, refractory bricks, hysil boards.* burner mounting arrangement with refractory burner block.furnace door:furnace door charging & discharging side fabricated from 5mm to 6 mm thickness door opening & closing automatic.ash door:* ash door (with casted cement lining) to remove nonhazardous ash from the chamber.* top inlet bottom smoke discharge for longer gas residence time.* furnace door charging & discharging side fabricated from 5mm to 6 mm thickness.* door opening & closing automatic/manual.refractory:{complete set of refractory shaped bricks for construction electric cremation of i.s. 8 bricks (approx. 1007nos bricks,insulation 4000 nos. refractory slid for construction of flue duct , as required, refractory heat resistant fire clay , ceramic blanket hysil board, asbestos ropes etc. as required for outer side of the furnace shall be constructed by red bricks by sand and cement as mortars and construction of chimney from basement of roof level including painting i.e. bricks portion shall be painted by two coats of red oxide as primer and to coats of synthetic enamel. (a) complete lining & assembling of entire cremation chamber according to standard size with proper arrangement of accommodation of heating elements, resting of dead body with sufficient opening for falling of ashes to the ash chamber & sufficient ventilation for fresh air spraying. (b) complete lining and assembling of entire cremation chamber according to standard size with provision of drawing out aces from the rear side and sufficient ventilation for fresh air injection. complete lining and assembling of entire cremation chamber according to the standard size with provision of air inlet supplying by fresh air blower and arrangement of multi ventilation path for fresh air}. osspl make, thermocouple heat sensor supply & fixing the thermocouple of heat sensing range 0 - 1200 c (cr.-al) sensor housed in s.s 304 casing of dimension 1200 mm long 22 mm od complete encased to and fitted terminal on other and for connection of compensating of 2 cores 0.5 aq. mm cr- al for heat sensing from thermocouple to temperature controller covered with asbestos embedded rope about 50 m length as per direction of eic., f.d. fan/centrifugal air blower with electric motor * supply and delivery at site, installation, testing and commissioing.* of fresh air injection system forced draft fan mild steel.* type: centrifugal.* capacity:- 500 cmh.* pressure:- 220 mmwg.* motor rating:- 2hp (kirloskar/crompton), burner assembly * total 2 nos. of lpg/cng/png fired automatic burner required.* the burner should be provided with comprising diffuser plate/ burner plate, photo cell housing electrodes with holding brackets, solenoid valve, electrodes caps, flexible hose pipes, spary nozzles, oil filter, blower, etc. connected with electric motor (each burner) & in built air regulator.* burners will work on auto on/off as per the set temperature for the combustion chambers.* the in-built bolwer will provide continuous air flow to the burners to prevent demages due to high temperature., supply and fixing of manifold with a p

CTN :42132622 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For mtps-i -bm-unit-iii- aoh-2025-26 - flue gas duct - ‘a’ & ‘b’ sides-patch up works and other repair works between aph out let to esp inlet.

corporations/Associations/Others

CTN :42135926 Due date: 17 Oct, 202517 Oct, 2025 NA
Tender For mtps i bm unit iii aoh 2025 26 flue gas duct a and b sides patch up works and other repair works between aph out let to esp inlet

State Government

CTN :42136907 Due date: 28 Oct, 202528 Oct, 2025 49.45 Lacs
Tender For supply and application of zinc rich paint for flue gas duct structure from air preheater out to chimney inlet in boiler unit no. 3 at sikka tps. - epoxy zinc rich anti-corrosion paint (90 percentage - 95 percentage zinc), zinc primer (epoxy base - 60 percentage zinc), thinner (g.p.) suitable for epoxy paint, charges for the application of zinc rich paint on flue gas duct structure from aph outlet to chimney of boiler unit no. 3 at sikka tps as per scope of works and instruction of eic

CTN :42093010 Due date: 20 Oct, 202520 Oct, 2025 NA
Tender For tender for supply of supply installation and commissioning of fully inverter type ivrf ac unit : : - supply of vrfv plus air conditioning system with energy efficient fully inverter scroll type compressors capable of delivering 100 % capacity at 43degree ambient and capable operating between 320v 460v with high performance oil accumulators self diagnostics redundant outdoor unit and indoor units.ivrfb 22tcn , indoor units with all supporting materials for hanging and fixing for existing duct. a. 6tr ducted indoor , b. 8tr ducted indoor , c. corded remotes , d. cordless remotes , installation , nitrogen pressure testing , vaccumising and commissioning of vrf odu units , installation charges for ducted indoor units , supply and laying of hard drawn copper refrigerant piping with elbows , couplings , reducer and slotted supports for suction and discharge line , supply and fixing of 19mm and 13mm thick nitrile rubber insulation for above copper pipe and ppe covering with fire retardant tape , refrigerant gas charging r410a , lifting , shifting and erection of ivrf outdoor units , communication cable for idu to odu , drain pipe cpvc with insulation , ms channel stand for odu units , scaffolding charges , dismantling charges for existing indoor units , dismantling charges for existing outdoor units , canvas fire proof for connection between indoor and cool air duct connection

State Government

CTN :41943242 Due date: 14 Oct, 202514 Oct, 2025 14.95 Lacs
Tender For supply of diversion plate for esp inlet/outlet flue gas duct of abvtps, cspgcl, janjgir-champa.

CTN :41963240 Due date: 13 Oct, 202513 Oct, 2025 NA
Tender For supply of 43.00. 00.603. 8 cold flue gas duct sections, 131f101 , 43.00. 00.604. 8 cold flue gas duct sections, 131f102

CTN :41814774 Due date: 03 Oct, 202503 Oct, 2025 NA
Location: Goa - Goa Goa - Goa
Tender For providing of customized annual maintenance contract/cmc for pre-owned products - annual maintenance contract of mig-29k ground support equipment (gse) for one year; ground support equipment; annual maintenance contract (amc); monthly; yes - air charging unit, nitrogen charging unit, oxygen charging unit, hydraulic jack, tow bar, hydraulic bottle jack, hydraulic stand for testing the jet nozzle, standardised crane of low lifting capacity, mooring facilities, wheel remover, hydraulic tyre puller, engine trolley, gas duct flushing and preservation unit, hydro stand for paz-mk servicing, equipment for pressure check shock strut, hoist fitting for engine, sling for canopy hoisting, mounting device, hoist sling rd33mk lifting in container, hoist sling for insert tank, lever plunger grease gun, pressure gauge radar cooling sys, conformal tank support, sling for wing mounting and canting, cockpit ladder, cradle support for cone, sling for external tank, support for a1505 cradles, chocks, manual hand operated trolley, brake bleeding gauge, engine inserter and remover, ksa-33m support (aagb stand), ejection seat trolley

corporations/Associations/Others

CTN :41908820 Due date: 09 Oct, 202509 Oct, 2025 NA
Tender For sitc of vrv vrf hvac system with allied equipments work st at esic hospital angul - outdoor unit 18 hp , outdoor unit 16 hp , cassette type indoor unit 1.2 tr , cassette type indoor unit 1.6 tr , cassette type indoor unit 2.0 tr , cassette type indoor unit 3.6 tr , hi wall type indoor unit 1.2 tr , high static ductable units 5.5 tr , high static ductable units 8 tr , 20 mm drain piping , 25 mm drain piping , 6.4 mm cu refrigerant piping , 9.5 mm cu refrigerant piping , 12.7 mm cu refrigerant piping , 15.86 mm cu refrigerant piping , 19 mm cu refrigerant piping , 22.2 mm cu refrigerant piping , 25.4 mm cu refrigerant piping , 28.58 mm cu refrigerant piping , 34.9 mm cu refrigerant piping , 41.3 mm cu refrigerant piping , cable tray of size 150 mm x 50 mm x 1.6 mm , cable tray of size 300 mm x 50 mm x 1.6 mm , cable tray bends of size 150 mm x 50 mm x 1.6 mm , cable tray bends of size 300 mm x 50 mm x 1.6 mm , cable tray tee of size 150 mm x 50 mm x 1.6 mm , cable tray tee of size 300 mm x 50 mm x 1.6 mm , gss sheet metal , gi volume control duct damper , aluminium supply air grills with damper , supply air diffusers , return air diffusers , class o insulation wit aluminium foil , pvc sheathed copper conductor , armoured cable 35 sqmm , armoured cable 70 sqmm , gland and lug , g.i wire , y joint or multijoint , refrigerant gas r410a , copper earth plate , 100 a 4p mccb , 63 a 4p rccb , 16 way double door mcb box , tpn double door distribution box , 25x5 mm gi strip , 6 swg gi wire , mcb 5 to 32 a , laying and fixing of pvc insulated xlpe cable , 20 mm pvc cassing , 25 mm pvc cassing

CTN :41928568 Due date: 16 Oct, 202516 Oct, 2025 NA
Tender For procurement of metallic expansion bellow for flue gas and air duct for unit- 5 o/h at bktps.
 Loading, Please wait...

Connect us via What's Up