Get complete information related to latest Pvc Meter Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pvc Meter Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pvc Meter Tenders.
Tender For purchase of various apparatus/instruments required for department of chemistry, chaudhary ranbir singh university, jind - stirrer the stirrer should be made up of ceramic coated aluminium alloy top with digital speed and temperature control. the stirring speed should be 50-1500 rpm or better. the stirrer should be operational up to a temperature range of 300oc with an accuracy of 1.0oc and ip 42 protection class. the input power should be 600 w or above. the stirrer should be supplied with hemispheric bowl (100 ml= 1 no; 250 ml= 1 no) to replace oil baths and mantles in order to perform clean and safe analysis with round bottom flasks., electronic balance the electronic balance should have a maximum weighing capacity of 200 g or more with a resolution and repeatability of 0.1 mg, and a response time of 5 sec or better. the system should have automatic internal calibration with touch screen display. the system should have internal database capacity of 2500 or more with multiuser password protection feature. , vacuum pumpthe pump should be operational at a maximum power of 65 w or more with a max. vaccum of 99 mbar or more. the pump should be fitted with vacuum and filter cartridge., hot air oventhe inner chamber should be made of stainless steel and the outer chamber should be m.s powder coated. the maximum capacity of the oven should be 100 ml or more. the operational temperature should be between ambient to 250 oc or more with a temperature accuracy of 1o c. pid based digital temperature control., double distillation unitthe unit should be pyrogen free with a distillation water output capacity of 1.5 l/h. the minimum cooling water requirement should be 1lt/min. auto-power cut facility in case of halted supply of water., circulating oil baththe oil bath should be made up of stainless steel with 4 digit 7 segment led display for temperature and time. the bath should have s.s perforated tray for holding flasks. the bath should have a capacity to accommodate flask of 1l. the working temperature range should be +5 to 240 oc (0.1 oc increment) with a temperature stability of 1oc., water baththe water bath should have a capacity of 20 l within built water level sensor. the bath should be made up of stainless steel and supplied with 8 concentric rings. the bath should have digital temperature control with pt100 sensor. the system should have stirring capability with ptfe magnetic bars. , ph conductivity meter operational between a ph range of -2 to 16.00 with a resolution of 0.01 ph and an accuracy of 0.02 ph. 5 points calibration. the ec range should be in between 0.00 to 29.99 s/cm, uv cabinet operational at two uv wavelengths (254 and 365 nm). the cabinet should also be equipped with one visible light. the external body should be coated with ms powder/epoxy., flame photometerapplication: the flame photometer is used for qualitative and quantitative determination of several cations, especially for metals that are easily excited to higher energy levels at flametemperature. these metals include na+, k+, ca2+, ba2+ and li2+.specification requirementmeasuring range na+: 0 to 99.9 ppm k+:0 to 99.9 ppm ca2+ :0-99.9 ppmli2+: 0 to 99.99 ppmsensitivity na+= 0.1 ppmk+ = 0.1 ppmspecificity less than 0.5% interference when concentrations are equal to test sample concentrationsgas control-adjustable with knobsignition system-auto ignition systemflame failure-auto detectiongas cut off-automaticreproducibility-less than 1% coefficient of variation for 20 consecutive samplesusing 10 ppm na set as maximum standardlinearity-less than 1%display led, 12.5 mm (1/2")fuel supply-high-grade propane/butane mixture regulated at approximately30 psiair supply-6 l/min at 12 psi; oil and moisture freerecorder-output 0.05 to 5 v (switchable)operating manuals, service manuals, other manuals should provide user, technical and maintenance manuals in english language list of equipment and procedures required for local calibration and routine maintenance service and
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - lab; equipment chemistry lab; service provider - analytical weight box 100 gm, chromatography cabinet 6 leaves, digital callorimeter with & filters, digital conductivity meter, digital do meter, kipps apparatus 500 ml, distillation app. double cap 5 litre, electronic digital balance cap.0.001gm-200 gm, electronic digital balance cap.0.01gm-600 gm, 0, heating mantle 51., 1, hot air oven size 14"x14"x14"s.s.chamber, 2, kjeldah digestion app with glass parts
Tender For supply of lab equipment - determination of work function and plank's constant using photoelectric effect , determination of hall co-efficient and carrier concentration of a given semi-conductor , characteristics of seriesa and parallel lcr circuits , v-i characteristics of a p-n junction diode and zener diode , input and output characteristics of bjt a) v-i , characteristics and l-i characteristics of led , determination of energy gap of a semiconductor , study b-h curve of a magnetic material , determination of dielectric constant of given material , understanding the method of least square torsional pendulum as on example, beakers(glass)- borosil, beakers -plastic, pipette - glass -borosil, burets plastic, conical flask - glass -borosil, winchester -bottles, watch glasses, dropper box, glass rods for stirring, tripods -iron, conical flask holder with stand, tangs -steel for holding purpose, forceps, filter paper, funnel holder stand (plastic or, pipette stand ( plastic ), test tubes, ostwalds viscometer, stopwatch, rubber tube, reagent bottles wide mouth -glass, reagent bottles wide mouth -glass, dessicator (100ml), mortar & pestle, concentrated hydrochloric acid, concentrated sulphuric acid, disodium salt of ethylene diamine, calcium carbonate (caco3), magnesium sulphate, ammonium chloide (nh4cl), ammonium solution (nh4oh), sodium chloride (nacl), glacial aceticacid, formaldehyde, phenol, hexamethylene diamine, adipoyl chloride, cyclohexane, distilled water, acetone, potassium hydroxide (koh), ethonol, diethyl ether, potassium dichromate, 5-amino -8-hydroxyquinoline, phenopthalein indicator -power, methyl orange indicator -power, 1- butanol, ph meter with electrode (digital) (elico brand), conductivity meter (digital)-(elico brand), potentiometer (digital) (elico brand), magnetic stirrer with stir bar, single pan electronic balance (1 mg or 0.1mg), hot plate, mantle (500ml), heating mantle -250 ml, oven (28-35liters), air dryer (hair dryer), refrigerator with freezer (150 lit), collar mics, public address system amplifier setup with speakers
Tender For printing technology laboratory equipment for government polytechnic gulzarbagh. spectrophotometer, digital ph meter , digital conductivity and hardness meter, flexo machine along with electronic web guide system, screen printing machine, sheet fed offset press, tensile tester, brusting tester, gsm tester, spiral and wire o binding m/c, comb binding machine, digital viscometer, gravure printing machine, digital printing press.