Web Analytics Made Easy - StatCounter

Pvc Trunking Tenders

Get complete information related to latest Pvc Trunking Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Pvc Trunking Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Pvc Trunking Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

corporations/Associations/Others

CTN :36532189 Due date: 25 Nov, 202425 Nov, 2024 4.00 Crore
Tender For corrigendum : supply of spare parts of vcbs - shunt closing coil with plunger assembly [aux volt: 110v dc] , series & shunt trip coils with plunger assembly & mounting bracket [4 coils = 1 set), shunt trip coil with plunger assembly [aux voltage: 110 v dc], fuse hrc link 10 a, hrc fuse base 32 a, spur gear big, spur gear small, pole assambly (barrier, vacuum interrupter & upper-lower bus bar), epoxy barrier, vacuum interrupter , roof bushing , roof bushing with copper stem & assembly , wiring of trolley, operating mechanism, (spring charged store energy), spring charging motor mechanism , ammeter selector switch , breaker auxiliary switch [contact: 6 no+ 6 nc], breaker auxiliary switch [contact: 8 no+ 8 nc], voltmeter [type: analog, size: 96x96 sq.mm] (range: 0-15 kv), ammeter (96x96 sq.mm) range: 0-100-200-400/5a , test terminal block rear connection, relay test terminal block , breaker control switch , trivector meter (tvm), ac ht static meter suitable for 3 ph 4 wire unbalanced load [ct ratio: 100-200-400/5a ptr: 11 kv/110 volt], numerical relay 3 o/c & 1 e/f, make _____, current transformer [ratio: 400-200-100/5-5a, stc: 16 ka protection core:5p/15 va, metering core: 0.5s/15 va], indoor single phase resin cast potential transformer, ratio: 11 kv/110 volt, burden: 100 va, , pt primary fuse [ rating: 11kv, 3.15 amp, , jaw contact / disconnecting contact [ ratio: 630 amp & above] , charging link with assembly for bb1-3, epoxy post insulator, wiring of trolley , type:rb1-3, power factor meter, shunt trip coil with plunger assembly, aux voltage: 110 vdc , bridge rectifier, power pack 100watt ,110vdc, upper terminal-l type, middle terminal-l type, earthing bus bar l type [50x6 mm copper], copper flexible bus bar, pt jumper, middle terminal-pad, top terminal pad, limit switch/micro switch, toggle switch, door switch, 32 pin plug socket, push button-black shroud, local-remote switch, terminal connector, indication lamp, antipumping relay, heater, thermostate, labour charges per breaker for inspection & fixing of required spare parts to put defective breaker in operating condition.
 Loading, Please wait...

Connect us via What's Up