Get complete information related to latest Quantitative Risk Assessment Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Quantitative Risk Assessment Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Quantitative Risk Assessment Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

Central Government And Public Sector

CTN :41033444 Due date: 15 Jul, 202515 Jul, 2025 NA
Tender For insulation monitoring relay 110 volt ac, range 50 v to 200 v ac insulation measuring range 25 kilo ohm to 100 kilo ohm, control supply-230 volts, 50 hz having fault memory test and reset button and alarm lead as per rcf specification edts-073 rev d amend 3. as per drg.no. nil specn: rcf specification edts-073 rev d amend 3

CTN :41002934 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For supply of supply of sitc of clean agent based fire suppression system at bpcl rajbandh top west bengal - 2 kg clean agent cylinder fitted with dlp valve , supply of 6 kg clean agent cylinder fitted with dlp valve , supply, installation end of line adapter. , pressure switch , health monitoring cum alarm panel , installation commissioning system , heat sensing tube ul

CTN :41002370 Due date: 29 Jul, 202529 Jul, 2025 NA
Tender For supply of quantitative risk assessment (qra) & hazop study , hira study , erdmp preparation as per pngrb regulation

Central Government/Public Sector

CTN :40848015 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For corrigendum : insulation monitoring relay rated 415 volts, 3 phase neutral isolated voltage - range 0 to 500 volts ac, insulation measuring range 0 to 500 volt ac, insulation measuring range 10 kilo ohm to 150 kilo ohm, control supply 230 volts %b1 10%, 50 hz having fault me mory test reset button and alarm lead as per rdso specification no rdso/pe/spec/0192 -2018 (r ev-1). make: m/s bender- ir 470ly-21a or equivalent of m/s abb or m/s contrel or m/s woka or m/s-schneider or m/s-siemens or m/s-dold. (to be supplied with oem's proof of purchase along with test certificate.) [ warranty period: 30 months after the date of delivery ]

Central Government/Public Sector

CTN :41021384 Due date: 18 Jul, 202518 Jul, 2025 NA
Tender For insulation monitoring relay rated 415 volts, 3 phase neutral isolated voltage - range 0 to 500 volts ac, insulation measuring range 0 to 500 volt ac, insulation measuring range 10 kilo ohm to 150 kilo ohm, control supply 230 volts %b1 10%, 50 hz having fault me mory test reset button and alarm lead as per rdso specification no rdso/pe/spec/0192 -2018 (r ev-1). make: m/s bender- ir 470ly-21a or equivalent of m/s abb or m/s contrel or m/s woka or m/s-schneider or m/s-siemens or m/s-dold. (to be supplied with oem's proof of purchase along with test certificate.) [ warranty period: 30 months after the date of delivery ]

CTN :40324015 Due date: 11 Jul, 202511 Jul, 2025 NA
Tender For corrigendum : computerised control, alarm and monitoring system (ccams) for orv project yard 3041

CTN :40955453 Due date: 17 Jul, 202517 Jul, 2025 NA
Tender For procurement of alarm and monitoring system (ams)

Central Government/Public Sector

CTN :40904413 Due date: 22 Jul, 202522 Jul, 2025 NA
Tender For electrification work in connection with provision of one common room for datalogger, eld, fuse alarm system monitoring and storing s&t critical maintenance spares at various stations/automatic huts on bsl division.

CTN :40865390 Due date: 17 Jul, 202517 Jul, 2025 77.00 Lacs
Tender For e-tender (2nd call) for procurement of laboratory instruments, equipment, appliances for the college of veterinary sciences and ah, rk nagar under the nec funded project for the year 2025-2026 - biosafety cabinetclassii, a 2 with accessories and power back up (bacteriology)-- the biological safety cabinet should be of class ii, type a2 designed in compliance with international standards the biological safety cabinet quoted instrument model must have international standards test likensf, tuv nord, en 12469 certification. certificate copy must be provided along with the technical bid. working area should be around 4foot. it should have exterior dimension w x h x d of 1300x 1568 x 800 and interior dimension wxhxdof 1200x 780x 630 it should have 1 piece grade 304 stainless steel or thermos scientific smart coat interior itshouldhavefeatureforpersonalprotection,sample protection, cross contamination protection and environmental protection. it must utilize brushless dc motor technology which uses significantly less energy with less heat emission provision compared to traditional ac motor technology to ensure lower levels of energy consumption. it should have 10 sloped front for exceptional comfort and ergonomics thesystemshouldbedesignedwithdualmotor. the motor must automatically adjust or control fan speed in real time to maintain constant airflow during filter loading or temporary obstruction. air flow direction: vertical laminar flow & air intake across front opening and 70% recirculation. filter: high performance particle air filter h14(hepa en1822), filtering efficiency 99.995% mpps or better. energy saving mode when cabinet not in use with maintaining sterility. continuous airflow helps to maintaina sterile environment, evenwhen the cabinet is not in use. thesystemshouldhaveindependentsensorstodetect pressure changes across the exhaust and down flow plenum/ air velocity and should indicate alarm signal when a 20-30% change in inflow/ exhaust or down flow occurs. control panel and performance monitor displays inflow/ down flow velocities, hours of use etc. to verify proper cabinet operation. frontglasswindowshouldbeeasilyloweredfor thorough smart cleaning of inner surfaces and designed to protect users by maintaining inflow, even when the window is lowered. the uv light must be quoted which should be programmable from 30 min to 24 hrs. in minimum 30 minutes increment to shut off automatically. the settings must allow the user to program the timer. the cabinet noise level must be less than 63 db(a) as measured in a sound proof room to promote more comfortable and safer working habitsof the user a per nsf/ ansi 49. the controller must be located on a slanted frontpanel so it is easy to see from a seated working position in front of the cabinet. control panel should be a large digital color touch screen display with health monitoring system, valuable safety and performance data with constant read-out of downflow/ inflow velocities and hours of operation in real-time, number of hours of use on the hepa filters. the front window sash must be angled 10 sloped front for operator comfort. two pieces of removable and autoclavable stainless steel arm rest should be provided for operator s comfort without disturbing the air flow. the system must have audio visual alarms to indicate when inflow is restricted and as well as whether front window is in correct position or not. theworkareashouldbeilluminatedwithswitchable fluorescent lamp of lighting power >120 fc or higher. suitable height floor stand without casters should be provided. in built access ports, 2 nos. (1 on each side) shouldbe available. it has single piece stainless steel work tray for easy cleaning and decontamination. warranty:minimum3year. electrical supply available: 230v a.c, single phase, 50 hz. bidder should provide printed brochure of the quoted model and details specification should be available in the manufacture website. customized model would not be accepted wi

State Government

CTN :40846282 Due date: 14 Jul, 202514 Jul, 2025 NA
Tender For comprehensive preventive and breakdown maintenance cum round the clock monitoring of fire detection and alarm systems at different building within the campus of calcutta pavlov hospital, kolkata, for one year