Tender For providing of custom bid for services - annual maintenance contract of computers peripherals server lan cctv network and other it items installed at chamera power station1
Tender For annual maintenance and upkeep of lan/ radio network devices installed at different road weighbridges rail weighbridges ( phulbasia siding, balumath siding and bukru siding), check posts, pm 10 analyzer, and project office kundi of magadh ocp, magadh
Tender For general-supply and installation of computer network system in roads maintenance division (first floor) pwd compound kottayam-lan-general electronics work
Tender For supply of sitc of ofc laying and network components rf link at rajahmundry airport - 24 port l2 switch with fully populated 4 sfp plus and 2 power supplies , serial to ip converter make moxa model n port 5250a , 4 port fxo voip gateway , 4 port fxs voip gateway , pair of rf link antennas along with out door lightening protector pair means 02 nos of antennas , cat 6 lan cable. , cat 6 patch cord 3 mts , single mode 12 core armored optic fibre cable , 24 ports fully loaded light guide interconnect unit liu ,19-inch rackmountable, fully populated liu with required pigtails, modules, connectors, etc. with splicing of all cores , suitable ofc patch cord lc-lc for connection betweenliu and sfp plus of switch of 5 meters each , wall mount 15u 500d 19-inch rack with glass door, pdu cable organizer, fans, mounting hardware etc. , 24 port cat 6 patch panel , 40 mm plb hdpe pipe and suitable hdpe conduit couplers for joining 40 mm hdpe pipes during laying of ofc cable , 40 mm gi pipe and jointer with all accessories , ofc splice enclosures where ever ofc joints are required , physical route markers , electronic ofc cable route markers with reader as per the site requirement for every 150 meters , manhole or inspection chamber having top cover with cast iron , laying of 12 core ofc cable through hdpe pipe and gi at depth of 6 to 7 feet with hdd digging and backfilling , label printer with 5 no.sof cartridges , installation testing integration and commissioning sitc of items mentioned above with warranty as mentioned in specifications document annexure a
Tender For sitc of server based ip epabx with 3 years post onsite warranty and 7 year camc at mysuru airport - supply of main and standby set of epabx system it should be of ip epabx with media gateway category based on server media gateway architecture and it can be integrated with existing bsnl setup , supply of desktop latest technology with relevant software for monitoring and controlling of epabx , supply of epabx operator console , supply of 24-port layer-2 poe switch with 1g 4 no. sfp port. , supply of 16-port layer-2 poe switch with 1g 2 no. sfp port , supply of fully loaded 42u rack 800x1000x2013 wxdxh with both side earthing strips , supply of 12u wall mount rack. , supply of executive ip phone poe based sets with 4.3 inches display. , supply of ip phone poe based sets with 2.4 inches display. , supply of analog telephone sets with cli and speaker. , supply of sfp-1g-lr. , supply of materials for conventional earthing system, with length of copper strip is 50 meters. , supply and laying of 6 core smf 9 125 micron 1000mbps fiber optic network cable including clamps connectors terminations splicing and all accesories etc , supply of fully loaded liu with 12 port rackmountable , supply and laying utp cat 6 data cable with connectors termination etc , supply and laying telephone cable with connectors termination etc , supply of 2.5 sqmm 3 core multi strand coppe wire power cable , supply of 24 port cat 6 io patch panel with shutter , supply of rj45 cat6e lan io network keystone jack gang box single port face plate 1 set , supply of cat3 rj11 6p4c phone telephone keystone jack io box , supply of gang box with input output rosette box , supply of rj11 telephone line cabl 3 meter. , supply of cat6 lan cables 3 meters. , supply and laying casing capping for lan cable wiring with all fittings l and t 100x40 mm size , supply and laying casing capping for lan cable wiring with all fittings l and t 30x10 mm size , supply of mdf main distribution frame with cover with 10 krone connectores 100 pairs , supply of idf intermediate distribution frame with cover 02 krone connectores 20 pairs , supply of 0.5mm armoured 20 pair jfc cable , supply of 0.5mm armoured 10 pair jfc cable , supply of telephone line spd , supply and laying of 50 mm dia hdpe pipe pn-6 , excavation in soft soil with the required depth up to 75cm backfilling with marking flag , excavation in hard soil with the required depth up to 75cm backfilling , training and documentation charges , installation testing and commissioning charges. , 4th year camc after completing 3 year warranty - only for sl no 1 and 02 , 5th year camc - only for sl no 1 and 02 , 6th year camc - only for sl no 1 and 02 , 7th year camc - only for sl no 1 and 02 , 8th year camc - only for sl no 1 and 02 , 9th year camc - only for sl no 1 and 02 , 10th year camc - only for sl no 1 and 02
Tender For comprehensive maintenance contract for lan (passive & active components) network at integral coach factory, chennai-600 038 for a period of two year
Tender For sitc of dual communication media - supply of 12 core smf armored optical fibre cable , supply of 24 port fully loaded liu, lc type , ofc patch cord lc-lc type , supply of stp cat-6a lan cable , supply of wireless radios. , supply of 24 port poe plus l-2 switch, , supply of 10g sfp plus transceiver modules , supply of 1g sfp transceiver modules , nms server hardware with required software , 65 inch display with wall ceiling mounting accessories , nms workstation with 23 inch monitor , otdr , supply of dual port serial to ip converter. , supply of 12 u racks , supply of frangible mast-5 meter along with installation accessories anchor bolt and mounting base plate. , class e spd for rj 45 , hdpe conduit flexible diameter 1 inch. , supply of installation accessories. , installation testing and commissioning of radio link network items material serial number a.2 ti a.19 except serial no a.1 , installations and laying of ofc in existing duct bank. , installation and laying of ofc with new duct bank , cost of onsite comprehensive annual maintenance contract for 1st year ocamc as per sla after completion of 1 year warranty. , cost of onsite comprehensive annual maintenance contract for 2nd year ocamc as per sla after completion of 1 year warranty. , cost of onsite comprehensive annual maintenance contract for 3rd year ocamc as per sla after completion of 1 year warranty. , cost of onsite comprehensive annual maintenance contract for 4th year ocamc as per sla after completion of 1 year warranty. , cost of onsite comprehensive annual maintenance contract for 5th year ocamc as per sla after completion of 1 year warranty.