Get complete information related to latest Radiation Monitor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiation Monitor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiation Monitor Tenders.
Tender For bid to ras corrigendum : supply of water cum foam monitor(2250 lpm) capacity with foam tank(500 liter) , trailer mounted , smoke extractor or exhauster conforming to is 941
Tender For corrigendum : annual maintenance contract for repair and maintenance of fire fighting equipment at erpl, rajbandh - amc for repair and maintenance of f&s eq, carrying out maintenance and inspection of fire extinguishers on monthly basis including pastings/ marking of maintenance date, clea ning, condition of threads of caps, discharge tubes, sharpness of piercing pin and cylinder body, replacement of defective parts ( iocl supplied), measuring weight and charges for labour, including oiling, greasing, testing as per direction of eic inclusive of al l tools &tackles, consumables, transportation, labour charges etc and measuring instruments for the same as directed by the eic/ si te engineer and submitting the reports of the inspection as per hse manual format (payment of spares not supplied by iocl shall be m ade as per respective items), for 10/9 kg. capacity dcp extinguisher, for 75/70/50 kg. capacity dcp extinguisher, for 4.5 kg. capacity co2 extinguisher, for 6.5 kg. capacity co2 extinguisher, for 2 kg capacity clean agent extinguisher, monthly: checking, inspection, maintenance, greasing, cleaning, oiling, replacement of disc washer, blank cap if any including compl ete overhauling etc. of double headed hydrant valves alongwith all tools, tackles, manpower, material etc. payment for disc washer, coupling washer & blank cap shall be made separately., supplying and fitting of hydrant disc washer as per directions of engineer-in-charge, supplying and fitting of fire hydrant/ fire hose coupling washer, supply and fitting of blank cap (as per is 5290 , red colour with gi chain) suitable for 63 mm hydrant outlet as per direction of ei c, supplying & fitting spindle assembly (gunmetal), repair of adaptor lug of hydrant/ hose inclusive of tools tackels & labour etc., monthly maintenance of 750 gpm monitors: oiling & greasing through grease nipple provided on bearing, worm wheel and worm shaft, cle aning, performance checking for complete vertical and horizontal movement, nozzle movement, water throw, foam suction, ensuring prop er tightning of flanges, clearing the debris around the nozzle etc as per approved procedure including tools & tackles, report submi ssion complete as per direction of site engineer / eic. water resistant low friction synthetic grease, grease gun and all other cons umable etc shall be arranged by vendor. after testing, afff jerry-can must be positioned and replinished near monitor including shif ting, transportation etc., cleaning, maintenance and repair of water cum foam monitor nozzle for fog jet operation by opening and dismantling of nozzle cleanin g by rustoline or kerosene of all the components thoroughly, further inspection of internal parts in the presence of the engineer-in -charge, repair/reconditioning by hand facing, machining, grinding, lapping, etc. and greasing,& reassembly in foam monitors as per direction of eic inclusive of necessary tools, tackles and labour., opening of blind flange of water curtain system of control building, sr tank cleaning of water line, dechoking of spray nozzles, ref ixing it with after testing with new gasket.etc of water spray system of all buildings (on monthly basis) including nozzle dechoking , strainer cleaning and all labour, tools & tackles complete as per direction of the site engineer/ eic. (rates per blind opening), valve maintenance : checking, inspection, greasing, cleaning, oiling etc. of all fire water valves, of all sizes upto 14" including grease and all labour, tools & tackles complete as per direction of site engineer / eic and provided by contractor. all such valves shall be fully closed and opened and restored in origional condition as per advise by eic/ site engineer.note: the valve sizes may vary from 3" to 14". rates are per valve., hydrotesting of fire fighting delivery hose of dia 63 mm on half-yearly basis (type a and b ) by making arrangement of hydraulic pum p, blind, shifting from plant area, bui
Tender For providing of calibration services - radiological calibration; calibration of radiationmonitoring equipment; any other government approved labs / service provider; buyer premises (onsite)
Tender For corrigendum : supply of spares for environmental radiationmonitors - low voltage power supply , high voltage power supply , area gamma radiation indicating meter with auto ranging , 6 digit electro magnetic counters , mains instrument transformers with line filter card , detector assembly with pmt with nai crystal , battery charger unit
Tender For corrigendum : supply of wide range area radiationmonitors - 1. ecil make wide range area radiationmonitors preamplifier pcs. , 2. ecil make wide range area radiationmonitors hv power supply. , 3. ecil make wide range area radiationmonitors lv power supply. , 4. ecil make wide range area radiationmonitors indicating meter. , 5. ecil make shutdown area radiationmonitors pre amplifier card. , 6. ecil make shutdown area radiationmonitors detector cable with connectors-25 meters. , 7. ecil make shutdown area radiationmonitors hv power supply. , 8. ecil make shutdown area radiationmonitors lv power supply. , 9. ecil make shutdown area radiationmonitors indicating meter.