Tender For corrigendum : procurement of disposable and implants items for ctvs department rgssh - part-01, oxygenator membrane (adult) with hard shell reservoir:1. should have a micro porous hollow fibre membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 4000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 7 ltr/min.5. should have priming volume less than 220ml6. should have high efficiency heat exchanger.7. venous return port with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 10. should have sampling port., oxygenator membrane (semi-adult) with hard shell reservoir:1. should have a micro porous hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 3000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow range 0.5 ltr to 3.5 ltr/min.5. should have priming volume less than 180ml6. should have high efficiency heat exchanger7. venous return port 3/8 with rotating facility.8. should have an auto vent facility.9. port size : arterial outlet, venous outlet 3/8 venous inlet 3/8 10. should have sampling port., oxygenator membrane (paed.) with hard shell reservoir:1. should have a microporus hollow fiber membrane oxygenator2. should have open circuit configuration3. should have hard shell venous reservoir of capacity more than 1000ml. with built of cardiotomy reservoir with 30 filter capacity.4. should have blood flow upto 2.8 ltr/min.5. should have priming volume less than 140ml6. should have high efficiency heat exchanger.7. venous return port 3/8 with rotating facility and redurs8. should have an auto vent facility.9. port size : arterial outlet 1/4 , venous inlet 3/8 with redurs, oxygenator membrane (neonatal):1. should have venous inlet .2. arterial outlet port tubing size.3. it should have least priming volume less than 70ml.4. arterial flow upto 1.2 ltr/minute.5. approximate reservoir capacity should not be 600ml.6. should have redurs.7. blood inlet and outlet port size redu able to 3/16 ., pre-connected tubing pack adult with arterial line filter:1. circuit diagram attached.2. tubing should have transparent, medical implant grade pvc of class vi usp, marked., pre-connected tubing pack paed. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack paediatric small. with arterial line filter:1. circuit diagram attached2. tubing should have transparent ,medical implant grade pvc of class vi usp, marked, pre-connected tubing pack neonatal. with arterial line filter:1. circuit diagram attached.2. it should have a good quality arterial filter pore size should have 35-40 micron.3. tubing should have transparent medical implant grade pvc of class vi usp, marked., online blood cardioplegia delivery system:1. should have in built high efficiency heat exchanger of metallic for fast cooling & re- warming.2. should have priming volume less than 80ml.3. should have max flow rate 1 ltr/min4. should have pressure drop not more than 13mmhg 500ml/min5. should have blood to crystalloid ratio of 4:1 with bride connection facilities and interchangeable tubing ratio.6. should have auto-vent line system on accidental bock of cardioplegia deliver liner.7. pvc tubing should have medical implant grade of class vi ,usp, marked., ante- grade root cardioplegia cannula with side arm:1. should have size 12fr,14 fr. & 16 fr.2. should have regular tip stilate with side arm for vent with flange3. selection strictly on quality basis., ante- grade root cardioplegia cannula without side arm:1. should have size 12fr, 14 fr. & 16 fr.2. should have regular tip stilate with flange3. selection strictly on quality basis.4. iso certification, coro
Tender For tender for supply of surgical and disposable item - 3 way stop cock , non pyrogenic and single use, should be leak proof, with smooth movements, 3 way stop cock with extension tube (vein-o extension line) size 10cm (non pyrogenic & single use), 3 way stop cock with extension tube (vein-o extension line) size 150cm (non pyrogenic & single use), abdominal belt, abdominal drain kit (with collection bag 2000 ml size 24, abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 16), abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) (size 20), abdominal drain kit, sterile, having drainage catheter and collection bag (2000 ml) size 28, abdominal drain kit,sterile,having drainage cather and collection bag(2000) ml size 32, absorbable gelatin sponge 80 x 50x 10mm, absorbable oxidized regenerated cellulose netsize 2 x 3 topical absorbable haemostatic bactericidal property, absorbent cotton wool 300 gm, absorbent cotton wool 500 gm, adult ventilator circuit single water trap, adult ventilator circuit with universal single limb, advance bipolar hand activated probe with 5mm shaft diameter and 35 cm shaft length with 5 mm wide, anti microbial gloves 6.5 inches, anti microbial gloves 7 inches, anti microbial gloves 7.5 inches, apple hunt trocar :- should be single use sterile trocars, have side port , two cannula & one trocar ,5 mm & 10 mm trocar with pyramidal tip, ergonomic design , fascia anchoring thread should be usfda / ce approved, aprin plastic disposable, arterial pressure monitor lines (100 cm long), arterial pressure monitor lines (150 cm long), asepto syringe with transparent bulb sterile, 60 ml, baby kit (cloth set for new bourn babies in summer use), baby kit (cloth set for new bourn babies in winter use), baby diapers pkt. of 5 pcs., band aid (water proof) long, bed paan plastic, bed protective plastic sheet disposables size 120x210cm, blood administration set blood transfusion set, breast pump, barbia three way foleys 22 fr, cannula fixer, care handloom guaze pad ( sanitary pad) pkt. of 10 pcs, carter thomason port closure :- should be carter thomson type port closure system, have pilot guide and suture passer separately, able to use for trocar defects of 5mm - 15mm, suture guide holes should be 180 degree access across each other s, single use , catheter,size 10(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 16(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 18(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, catheter,size 8(foleys ballon catheter sterile,2 way for urinary drainage,single use,)silicon coated natural latex material, ceasarian drape sheet, central line triple lumen with y needle and nitinol guide wire 7fr to 8.5 fr with 15cm to 20cm catheter with tecoflex/polyurathane material, central neck line ? double lumen (antimicrobial coated/ chlorhexidine , silver sulfadiazine coated) central lumen catheter, double lumen) 7 fr, close suction system adult fr-14, close wound drainage device under negative pressure (closed wound suction unit) 10 no, close wound drainage device under negative pressure (closed wound suction unit) 8 no, close wound drainage device under negative pressure (closed wound suction unit) no. 12, close wound drainage device under negative pressure (closed wound suction unit) no. 14, close wound drainage device under negative pressure (closed wound suction unit) size of bellow 800 ml, catheter size 16, close wound drainage device under negative pressure (closed wound suction unit) size of bellow 800 ml, catheter size 18, combined spinal & epidural set latex free disposable pencil point spinal needle 27g , 127.5 mm with grooved transparent hub with centering protective plastic sleeve, touhy needle with black
Tender For corrigendum : supply of lab equipment - details decription attach in the specfication document ), bench top single beam systronics uv spectrophotometer 340 999 model no 167 covers 190to 1100 nm 4 position cuvette holder automatic wavelength selection 128x64 graphical lcd printer interface usb computer interface with professional scanning software specifications wavelength range 190 1100nm spectral band width, remi cis 24 plus orbital shaking incubator size 580 by 600 mm shaking speed range 20 to 250 rpm voltage 220 240v external dimensions 800 x 1150 x 1300 mm chamber volume 215 ltrs, manual baby mini power pack manual bio world, mini horizontal gel electrophoresis system, advance rotary microtomy latest spencer 820 type with razer, compound microscope, laboratory hot air oven, laboratory eggs incubator capacity 80 lit, ph meter digital, conical flask 200 ml insufficient number available, electronic balance, gel electrophoresis assembly with digital power pack, thermal cycler, cooling centrifuge, gel documentation unit with computer, micropipette, tips of micropipette, eppendorf tubes, pcr tubes, deep freezer, laminar air flow, ph meter, soxhlet apparatus with heating mantle, autoclave, bottle top dispenser with dual inte technology, centrifuge, digital chemical balance, double door refrigerator, d o meter, digital ph meter with electrode lcd display, digital photoelectric colorimeter, digital potentiometer, distillation apparatus, dryer and temperature controller, blower, chemical thermometer, calorie meter, beaker 50ml 100ml 250ml 500ml and 1000ml catering to various volume crafted from high quality 3point3 borosilicate glass the low form design with a wide base and tapered spout, funnel, pipette, burette, burette stand, mortar pestel, electronic balance, burette brush, test tube brush, conical flask, volumetric flask capacity sg 100 100ml sg 250 250ml sg 500 500ml sg 1000 1 000mlmaterial glass heat resistance with graduation, wire gauze, round bottomed flask, periodic table poster, gas connection and fitting in new lab, water bath digital, digital ph meter, digital blood pressure machine, blower, single needle lock stitch sewing machine, over lock or inter lock sewing machine, usha steam ironpro s13816, notice board, inverter, water coller
Tender For bid to ras supply of sitc for vrindavan dch - bowl and splash guard , one thousand two hundred w x twothousand one hundred h for main storage , surgeonsdouble arm pendant ce marked with electrical socketoutlets etc and provision with gas outlet , anesthesia singlearm pendant ce marked with electrical socket outlets etcand provision with gas , dual dome led ot light as perminutes specifications and annexures referred above forregular ot , camera as par requirement , monitor as parrequirement , white ceramic writing list board as perminutes specifications and annexures referred above forregular otsize six hundred and fifty x twelve hundred mm ,medical grade isolation transformer as per minutesspecifications and annexures referred above for regular ot, hatch box for dirty disposal material and finish same aswall panels with two mechanically interlocked doors size sixhundred x six hundred x six hundred mm , operationtheater antistatic conductive two mm thick imported pvctile flooring complete with application of self levelingcompound laying of copper grounding strips , medical gaspipe line inside of ot , pressure relief damper pressurerelief damper made up of three hundred and four gradedstainless steel blades with all accessories , tower ac withstabilizer , radiation protection pannel for one room barcapproved four wall and one roof total equal to five partrequired for one room radiation , non invasive five functiontest machine hemoglobin bilirubin sugar oxygen levencreatinine in thirty seconds without blood sample , noninvasive bilirubin monitor , anti static anti bacterial wallprotector price per mtr , three seater bench with foamcousin ss high quality , nurse call system twenty bedded |