Get complete information related to latest Radiology Film Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiology Film Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiology Film Tenders.
Tender For corrigendum : supply of airconditioning work at sbi motiram adda branch under rbo2 ao gorakhpur d d - supply of cassette ac, 3.0 tr single phase only bee 5- star inverter ac , supply of hi-wall split ac, 1.5 tr bee 5- star inverter ac , supply of hi-wall split ac, 1.0 tr bee 5- star inverter ac , installation of 3.0 tr cassette ac , installation of 1.5 or 1.0 tr hi-wall split ac , supply and installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 3.0 tr cacs , supply and installation of copper refrigerent pipes with min thickness 0.7 mm or higher for 1.5 or 1.0 tr sacs , supply and installation of interconnecting wires for 3.0 tr cassette acs , supply and installation of interconnecting wires for 1.5 or 1.0 tr hi-wall split acs , supply and installation of 25 mm pvc drain pipes with insulation , supply and installation of ms angle for outdoor units , supply and installation of 4.0 kva stabliser having copper winding with voltage range of 130 - 280v , supply and installation of 5.0 kva stabliser having copper winding with voltage range of 130 - 280v , dismantle shifting and reinstallation of old existing 2.0 or 1.5 or 1.0 tr hi-wall
Tender For corrigendum : supply of vrf ac work at hlc gomti nagar d d - 20 hp outdoor vrv or vrf , 4 way 2.0 tr vrf cassette indoor , 4 way 1.3 tr vrf cassette indoor , y joints , installation of vrv or vrf outdoor , installation of 2.0 casssette vrf indoor , installation of 1.3 casssette vrf indoor , commisioning of complete vrf system , refrigerant piping 28.6 mm , refrigerant piping 22.2 mm , refrigerant piping 19.1 mm , refrigerant piping 15.9 mm , refrigerant piping 12.7 mm , refrigerant piping 9.5 mm , refrigerant piping 6.4 mm , drain pipe 32 mm , drain pipe 25 mm , control and transmission wiring , ms sloted angle for pipe paying , outdoor stand for vrv or vrf 20 hp , sitc of 5 star 2 ton cassette a c , copper pipe refrigerant piping for 1.5 or 2 tr , interconnecting standard wire cable , drain pipe , ms stand , 5 kva automatic stabilizer
Tender For providing of custom bid for services - operation maintenance of centralized ac plants package ac units split n cassette type ac units deep freezers refrigerators cold storage
Tender For supply of canon copier consumable parts : : - canon ir advc 3720 - seperation roller , canon ir advc 3720 - paper pickup roller , canon ir advc 3720 itb , canon ir advc 3720 - cassette auto close assembly , canon ir c3120 - seperation roller , canon ir c3120 - paper pickup roller , canon ir 2625 - seperation roller , canon ir 2625 - paper pickup roller , canon ir 2625 - adf roller kit , canon ir 2625 - laser scanner assembly , canon ir 2625 - cam unit , canon ir 2625 - usb relay pcb assembly
Tender For supply of vrf or vrv airconditioning system for circle office madurai d d - si of vrf outdoor units , sitc of vrf idu , supply of cordless remote controller with receiver for 4-way cassette. , sitc of lcd touch screen , refnet joints , lifting and shifting charges of odu from gf to sf , lifting and shifting charges of odu from gf to tf , lifting and shifting charges of idu from gf to tf , pressure testing and pressure holding nitrigen , testing and commissioning of vrf systems , refrigerant pipe for vrf system , communication cable , drain piping with 9 mm thick nitrile rubber insulation. , supply and charging of r-410a refrigerant , protective glass wool tape above the copper pipes , 2.5 inch pvc pipe for exposed coppe pipes area , sitc of underdeck insulation of ceiling , supply and fixing of ms angle iron, channel, chequered plates with 2 coats of primer, 2 coats of enamel paint and complete in all respect etc. , perforated cable tray , ventilation fans , gi round duct 22swg , powder coated extruded aluminium of 18 g disc valve , supply and installation of insulated flexible ducting, complete with connecting rings, aluminium foil tape, duct supports etc. , dx system biq , supply, installion and testing of interconnecting copper refrigerant pipe , electrical power cable from power mcb to odu , control cable between idu to odu with conduits and necessary fittings and accessories. , insulated pvc drain piping for indoor unit with 9 mm thick nitrile rubber insulation. , comprehensive amc charges , buyback offer for acs
Tender For annual maintenance of high wall cassette vertical split ac and window ac system of college building new ss building animal building morgue building eye building blood bank and other buildings under agmc gbp hospital agartala tripura for 01one year4th
Tender For supply of air condition system for manufaturing inspection c c - variable refrigerant flow consisting of one outdoor and multiple indoor units refer details as per specification , vrf 4 way cassette ac capicity 4 tr refer details as per specification , installation of all the above odu and idu cassette vrf unit with hanging rods refer details as per specification , copper pipe of minimum thickness 1 point 6 mm or higher from 1st idu to 6th idu as per site requiremen refer details as per specification , cpvc drain pipes hot and cold with fittings main cpvc drain pipe size shall be 4 inch or higher refer details as per specification , cable tray with cap for idu copper pipings from unit to unit refer details as per specification , cable tray with cap for main line from odu to 1st idu unit refer details as per specification , communication cable 2 point 5 sqmm 2 core refer details as per specification , power cable 3 core 4 sq mm with 32 amps with 2 poles mcb and socket refer details as per specification , 30 sq mm 4 core cable with 100 a and 4 poles mcb with proper earthing from odu to idu mcb refer details as per specification , conduit for cable 1 inches with fittings refer details as per specification , n2 pressure testing for all circuits refer details as per specification , welding work refer details as per specification , odu stand refer details as per specification