Get complete information related to latest Radiotheraphy Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Radiotheraphy Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Radiotheraphy Tenders.
Tender For purchase of equipments - purchase of equipment:chromatographic workstation with capillary injector, packed injector, and auto-sampler should be quoted. chromatography workstation instruments should be built with self-diagnostic features and active-time management tools for better productivity, general features of chromatography workstation: column oven can accommodate two columns with maximum temperature range up to 400 c with set point resolution of 0.1 c. it should support 20 ramps & maximum temperature ramp rates of 100 c /min. cool down of oven from 400 c to 50 c in less than 5 min. fully automated with electronic pneumatic control afc / ppc / epc (digital control) for injector gas afc/epc/ppc should provide optimum performance with all types of capillary columns. system should have the capability to install a minimum of three injection and four detector ports. capable of detecting h and o across 0.01% 100% ranges (i.e., both trace in a matrix and bulk near-pure streams) column oven: operational temperature range: ambient +10 to 400 c overheat protection: programmable up to 420 c injector port: split/spitless injector 1 no packed injector 1 no, maximum temperature: 400 c, pressure setting range 0 100 psi with control setpoint of 0.01psi for specified pressure range., carrier gas flow control should have constant flow, constant pressure modes and constant linear velocity. auto injector: automatic sample injector up to 15 vials 2 ml vial with crimp set 100 nos, detector: flame ionisation detector (fid) 1 no, minimum detectable quantity: 3 pgc/s or more liner dynamic range: 1 107, maximum acquisition rate: 4 ms (250hz), thermal conductivity detector, sensitivity: >40000 mv maximum acquisition rate: 4 ms, maximum operating temp: 400 cgas cylinders & fittings, gas sampling: zero air, h2, n2 and helium gas cylinder with 2-stage regulators, each 1 no. four-stage gas purification panel and gas tubing. quote a suitable gas sample injector apparatus for the analysis of co2 gas, gas standards and a suitable packed column quote a 6-port gas sampling valve suitable for both manual (through syringe) and auto injection (online) quote sample line, sample loop, heated lines, filters, safety hydrogen purging, and flow control of gas. calibration gasses: suitable gas standards such as ar, he, h2, o2, co and ch4 should be providedpc and ups: pc i5 (or higher), 8gb ram, 1tb hdd, 22-inch led monitor (or higher), ssd: 512 gb, windows 10 os (or higher), wired keyboard and mouse. laser printer b/w, online ups sine wave capacity of 5 kva with battery power backup of 1 hour should be provided by the supplier general terms and conditions:warranty: 3 years manufacturer s warranty certificate. vendor should be an authorised provider of sophisticated high-precision chromatograph workstation systems for the past 15 years or more with: a proven track record in multiple countries and national institutes standard quality certifications such (iso 9001) 5+ past installations of similar systems in india. compliance statement should be enclosed with the quotation. the installation should be done at free of cost. hands-on training for 1 day for two trainees (faculty and scholars) must be provided on operation, maintenance and troubleshooting to two to two-three persons at the site of installation. if required, hands-on training must also be given to our faculty/scholars at a later stage, without any financial commitment to university. the technical details of the quoted instrument must be available on the official website of the principal supplier. the vendor should provide the list of end-users (recent) with contact details. the vendor must submit the latest reference letters from their previous users. trained service engineers in india (with suitable certificates) for the quoted model must be readily available to resolve the technical problems. a list of recent scientific publications in reputed journals from the user institutions where the quoted mode
Tender For corrigendum : providing of operation and maintenance of electrical systems/electrical installations - diagnostic testing of lt power and control cable at nrl site
Tender For providing of repair, maintenance, and installation of plant/ systems/equipments (version 2) - industry unit; carry out electrical diagnostic tests on two nos of 38 mva generators at hurl barauni; as per nit
Tender For corrigendum : supply of hysteroscopic instruments - supply of hysteroscopic instruments, diagnostic hysteroscope-- feature specification- outer diameter 2.7 mm - working length 250 mm 300 mm- angle of view: 30 - field of view wide-angle ( 80 )- image transmission rod lens system (preferred), or fiberoptic- sheath size 3.5 mm (outer sheath)- distension media normal saline or co (based on system compatibility)- light source connection standard fiber optic light post (compatible with xenon or led sources)- port type luer lock inflow port (optional outflow depending on model)- sterilization autoclavable or low-temperature plasma sterilization- material surgical-grade stainless steel and medical-grade polymers, operative hysteroscope (4 mm)- telescope diameter 4.0 mm- working length 270 300 mm- outer sheath diameter 5.5 mm (depending on continuous flow or single-flow sheath)- working channels 1 or 2 channels, standard 5 fr (1.7 mm) instruments- angle of view 30 (standard)- field of view wide-angle, distortion-free- image system rod lens optical system, hd-compatible- sheath type continuous flow (inflow and outflow channels)- material surgical-grade stainless steel- light transmission fiber optic light post, universal connector- distension media compatibility normal saline (for bipolar energy) or non-electrolyte fluid (for monopolar)- electrosurgical compatibility bipolar or monopolar electrodes (rollerball, loop, hook, etc.)- electrode type supported 5 fr electrodes resectoscope type- instrument compatibility operative scissors, graspers, biopsy forceps (5 fr)- sterilization autoclavable (134 c) or low-temperature plasma sterilization, hysteroscopic resectoscopesheath & telescopeouter diameter: 4.0 mm working channel: 1.5 2.0 mm (for scissors, biopsy forceps, graspers, bipolar electrodes)angle of view: 30 length: ~25 30 cmfibre optic light transmission with high-resolution rod lens systemresectoscope system (if using with loop / rollerball)available as mini-resectoscope (4.0 mm)compatible with bipolar energy sourceworking element: spring-loaded resectoscope with 4 mm telescopeelectrodes: loop, rollerball, knife, needle (bipolar compatible)fluid managementcompatible with saline (0.9%) as distension medium (for bipolar)continuous flow sheath for clear visioninflow/outflow channels for pressure-controlled irrigationother featuresautoclavable stainless steelergonomic design for operative stabilitycompatible with standard hd camera and light source systems, hysteroscopic scissors size: 5 fr (~1.7 mm), 30 36 cmpasses through working channel of 4 mm hysteroscope.types: straight / curved / angledmaterial: stainless steel, autoclavable, hysteroscopic biopsy forcepssize: 5 fr (~1.7 mm), 30 36 cm long.fits into working channel of 4 mm operative hysteroscope.types: biopsy (punch), grasping, scissors.jaws: serrated, single/double action, rotatable.reusable (autoclavable)., hysteroscopic morcellatorsystem componentshandpiece with cutting blade (rotating/reciprocating)inner cutting tube (sharp-edged) inside outer sheathcontinuous suction attached simultaneous cutting + tissue removalcompatible hysteroscope sheathdimensionssheath outer diameter: 6 7 mm (mini systems available with 5 mm)working channel: 3 3.5 mm (for morcellator blade)blade sizes: 2.5 3 mm (straight or side-facing cutting window)length: 26 30 cmoptics0 or 12 telescope, 2.9 4 mm rod lenshigh-definition fibre-optic illuminationenergy / working principlemechanical cutting continuous suction for clear vision and specimen collectionworks with normal saline as distension medium, hysteromat fluid management systemspecificationsmedium used: co (rarely now) or, preferably, fluids (normal saline, glycine, mannitol, sorbitol).pressure range: adjustable, usually 30 150 mmhg.flow rate: 50 500 ml/min (depending on model).display: digital display for set pressure, actual pressure, inflow, outflow, and fluid deficit.safety: audible alarms for excessive pressure or fluid deficit (to prevent ove