Tender For corrigendum : supply of control valves for lara singrauli and talcher projects - lara-cv-asv-8, dea pegging from aux. steam header , lara-cv-crhv-6, dea pegging from crh line , lara-cvcdv-25, low load condensate control , lara-cvcdv-39, gsc min. flow recirculation , lara-cv-cdv65, cep-a min. flow recirculation , lara-cv-cdv-67, cep-b min. flow recirculation , lara-cv-cdv-69, cep-c min. flow recirculation , lara-cv-cdv-43, excess dump control , lara-cv-cdv-72, condensate for valve gland sealing and flash tank , lara-cv-cdv84, condensate spray for flash tank , lara-cv-cdv94, condensate spray for unit flash tank , lara-cvdrv-53, hph-9a normal drain to hph-8a , lara-cv-drv59, hph-9b normal drain to hph-8b , lara-cv-drv-56, hph-9a alt drain to flash tank , lara-cv-drv-62, hph9b alt drain to flash tank , lara-cv-drv-2, hph-8a normal drain to hph-7a , lara-cv-drv-8, hph-8b normal drain to hph-7b , lara-cv-drv-5, hph-8a alt drain to flash tank , lara-cv-drv-11, hph-8b alt drain to flash tank , lara-cv-drv-15, hph-7a normal drain to deaerator , lara-cv-drv-22, hph-7b normal drain to deaerator , lara-cv-drv-18, hph-7a alt drain to flash tank , lara-cv-drv-25, hph-7b alt drain to flash tank , lara-cv-drv-82, lph-5 normal drain to lph-4 , lara-cv-drv-85, lph-5 alt. drain to flash tank-b , lara-cv-drv-65, lph-4 normal drain to lph-3 , lara-cv-drv-68, lph-4 alt. drain to flash tank-b , lara-cv-drv-77, drip pump discharge control , lara-cv-drv-31, lph-3 alt. drain to flash tank-b , lara-cv-drv-48, deaerator overflow to flash tank-b , lara-cv-dmv-43, normal dm mu to hotwell , lara-cv-dmv-78, emergency dm mu to hotwell , lara-cv-asv-16, drain of aux steam from existing unit header to unit flash tank , lara-cvdmcwsg12, dmcw system for sg aux , lara-cvdmcw18, dmcw system for tg aux , lara- one fourth inch ss tubing -12 meter for each tag , lara- ss fittings for connection to air filter regulator- for each tag , lara- ss fittings for connection to air lock relayfor each tag , lara- ss fittings for connection to ia header isolation valve - for each tag , lara- ss equal tee - for each tag , lara- ss half inch npt m x one fourth inch od tube connector- for each tag , lara- commissioning spares gaskets and gland packing set for each valve , lara- valve diagnostic and configuration software , lara- cv test charges , lara- mandatory spares- pneumatic and electro hydraulic actuator assembly or equivalent item applicable for selected actuator type shall be provided, 1 no. of each type model and rating , lara- mandatory spares- diaphragms, o rings, seals etc.- 5 nos. of all types make etc. , lara- mandatory spares- solenoid valves if applicable - 1 no. of each type , lara- mandatory spares- smart positioners complete unit and accessories link assembly - 2 nos. of each type, model and rating , lara- mandatory spares- pneumatic air filter or regulator- 2 nos. of each type, make rating etc. , laramandatory spares- air lock relays- 1 no. of each type, model and rating , lara- mandatory spares- valve trim - including cage, plug, stem, seat rings, guide bushings etc. - 1 set for each type,class,size of control valve , lara- mandatory spares- gland packing- 5 sets , lara- mandatory sparesgaskets- 5 sets , lara- mandatory spares- cep recirculation valve trim which includes spindle with cone, seat ring, guide bush, cage- 1 set , lara- mandatory spares- cep recirculation valve soft parts i.e. gland packing, seals, orings, gaskets etc.- 3 sets , lara- mandatory spares- ss fittings for connection to air filter regulator- for each tag- 100 nos. of each type , lara- mandatory spares- ss fittings for connection to air lock relay- for each tag100 nos. of each type , lara- mandatory spares- ss fittings for connection to ia header isolation valve- for each tag- 100 nos. of each type , lara- mandatory spares- ss equal tee- for each tag- 100 nos. of each type , lara- mandatory spares- pneumatic air filter or regulator- 20 nos. of each type and model , laramandatory spares- v
Tender For 5hp non clog submersible sewage pump set, pumping capacity 72 cubic meter per hour at 8 mtrs head with speed 1450 rpm, complete with water protected seal for continuous operating 415v, 50 h z, supply with 10 mtrs, resin filled control cable and 10mtrs s.s chain with shackle and suitable fully auto matic three phase starter control panel (dol/star delta starter which is suitable for that pump) along with s ingle phase preventer with phase reversal sensing and dry run relay protection (current sensing type), ther mistor relay and moisture control relay, analog /digital voltmeter , analog /digital ammeter , power on/trip and indication lamps, on/off switch and auto/manual mode switch (authorized dealership certificate to be e nclosed while submitting offer, test certificate and warranty certificate to be submitted along with supply). make: ksb or kirloskar or mbh or karvel or similar [ warranty period: 30 months after the date of d elivery ]
Tender For equipment items - behavior of proximity sensors kit inductive and capacitive proximity sensors, relay, buzzer, suitable power supply unit , performance of light sensor test kit ldr, mc ammeter and voltmeter, 0-30v dc power supply unit, dc motor with optical sensor set up , performance of ultrasonic and moisture sensors arduino shield, arduino compatible ultrasonic sensor and moisture sensor , observe the behavior of transistor as a switch push button, spst, spdt, limit switch, low voltage dc motor, transistor and relay , forward and reverse control of ac motor 3 phase induction motor, forward reverse control switch and clamp meter, servo motor control with an arduino arduino shield, arduino compatible servo motor and potentiometer
Tender For sewage submersible pump set 5 hp capacity non clog type with 10 mtrs outlet hose, outlet 1 00mm, pumping capacity 72 cubic meter per hour, 8 meter head with speed 1450 rpm, complete with wate r protected seal for continuous operating 415v, 50hz supply with 10mtrs resin filled control cable and 10mt rs s.s .chain with shackles and suitable fully automatic three phase starter control panel (dol starter suita ble for the pump) along with single phase preventer with phase reversal sensing and dry run relay protectio n (current sensing type), thermistor relay and moisture control relay, analog / digital voltmeter, analog /digi tal ammeter, power on, trip and indication lamps, on/off switch and auto/manual mode switch. make acce ptable: grundfos / deccan / kirloskar/ cri / ksb / mbh / psg / crompton / suguna / karvel. oems or authoriz ed dealer only to quote with documentary evidence. test certificate and warranty certificate to be submitte d along with supply. the firm has to indicate the make and model number in their offer to assess the techni cal suitability. [ warranty period: 12 months after the date of delivery ]