Tender For supply of repair of ms frame,removing and fixing of puff panel,puff panel,removing of grid ceiling,providing and fixing of grid ceiling,providing and laying of pcc,providing and laying of tiles,removing and refixing of aluminium doors,aluminium doors,providing and fixing of aluminium doors and windows shutter,partion removal,wiring of 6 amp light points,wiring of 16 amp light points,wiring of fan points,wiring of ac points,pvc conduits 25mm,pvc conduits 32mm,flexible pipe 25mm,flexible pipe 32mm,distribution board,ups distribution box,distribution box,ac unit,wall fans,wiring to mcb,electrical accessories,lights,exhaust fans,tube,red oxide paint,emulsion paint,apex paint,rust treatment
Tender For state plan supply and laying pipe line at various places in varkala legislative constituency budget outlay under state plan 2021 2022 appendix replacement of 450mm ac from triveni supermarket to kannamba road in varkala municipality pipeline
Tender For supply of transportation of ac units,itc of split ac unit,supplying and fixing extra copper pipe line,providing and fixing 20mm dia pvc pipe,supplying and fixing of powder coated heavy duty iron stand,supplying and laying 3 core 2 point 5 sqmm copper cable,supplying and fixing of timmer,removing of all window or split ac,closing the opening of ac unit,supplying and fixing 4 way single pole and neutral mcb db,wiring for light power plug,supplying and fixing 20a sp mcb,supplying and fixing 40 a dp isolator
Tender For supply of providing air conditioning facility of various labs and sitting areas at nrsc balanagar : : 5 =5 = - supply installation testing and commissioning of inverter cassette ac units , supply and laying suction copper pipe line for inverter cassette ac units , supply and laying liquid copper pipe line for inverter cassette ac units , supply installation testing and commissioning of minimum 2 tr inverter split ac units , supply and laying suction copper pipe line for 2 tr inverter split ac , supply and laying liquid copper pipe line for 2 tr inverter split ac , supply and erection of 25 mm condensate drain pipe , supply and erection of 32 mm condensate drain pipe , supply and installation of minimum 100 mm durable pvc pipe , supply and installation of heavy duty floor mounted metal stands , unarmoured control cable , unarmoured power cable
Tender For 400 mm dia ms pipe shifting near jubilee park and ac pipe line taking out and 100 mm dia di pipe laying near jubilee park at ward no. 5 and 160 mm dia hdpe pipe linelaying at ward no. 6, 9 and different dia lrc fit within gayeshpur municipality
Tender For corrigendum : tender for supply of boq for sitc of addl acs for sagarika including camc : - sitc of approx 16 and a half tr fixed speed ductable split type jet diffuser ac systems including indoor and outdoor unit r410a refrigerant including all materials for commissioining foundation works asethetic covering materials for indoor units etc , supply and charging of additional refrigerant r407c , supply and installation of hard drawn copper refrigerant piping of various dia with 13 mm nitrile rubber tubular insulation for 16 and a half tr ductable air conditioners , supply and installation of suitable casing and caping 300 mm for enclosing copper refrigerant piping , supply and installation of control cabling between indoor to outdoor of ductable unit with conduit pipe 2 and a half sqmm 4 core , sitc of canvass connection , sitc of fabricated ducting plenum jsw 120 gsm box 24 g rectangular duct tdf , supply installation of round alu powder coated jet diffuser with damper of desired dia as per cfm requirements and locations , supply and fabrication of ms channel or angle pedestal for outdoor units , supply and fabrication of ms channel support for idu and duct plenum hanging arrangements , sitc of 32 mm rigid pvc drain piping with 9 mm nitrile rubber tublar insulation complete fittings u trap as specified nearest drain point , sitc of 32 mm rigid pvc drain piping without insulation complete fittings u trap as specified nearest drain point , sitc of lt panel board ip 54 incomer 1 no 200a 4p mccb outgoing 1 no 160 a 4p mccb 3 nos 63a 4p mccb as per annexure , sitc of mv panel with incomer 1 no 160 a 4p mccb outgoing 5 nos 63a 4p mcb including all materials as required , supply and laying of 3 and a half 185 sq mm aluminium armoured cable under ground ceiling supports clamping along walls including all materials as required , supply and laying of 3 and a half 120 sq mm aluminium armoured cable through ceiling supports clamping along walls etc including all materials as required , supply and laying of 3 and a half 50 sq mm aluminium armoured cable , supply and laying of 4 x 16 mm copper armoured cable outdoor isolator to odu , supply and end termination of 3 and a half 185 mm aluminium armoured cable , supply and end termination of 3 and a half 120 mm aluminium armoured cable , supply and end termination of 3 and a half 50 mm aluminium armoured cable , supply and end termination of 4 x 16 mm copper armoured cable , supply and installation of 63 a 4 pole isolator with lockable box , supply and installation of 25 x 3 gi strip outdoor unit earthing , supply and installation of 10 swg copper earthing panel db and isolator box , excavation for laying 3 and a half 150 sqmm cable and replacing the interlock tiles etc , sitc of b class gi pipe of size 65 mm for laying cables , sitc of 250 a mccb in existing mv panel at substation after removing the existing 125 a mccb with suitable modifications including all materials as required , providing protective polycarbonate sheet covering in existing outdoor ducting units to prevent rainwater and sunlight directly falling above the ducting items fabrication of covering system with gi angles 40x4 pipe supports 50 mm epoxy painting foundations for supports etc as required , camc for 3rd year after 2 years guarantee for ductable split type jet diffuser ac systems , camc for 4thyear after 2 years guarantee for ductable split type jet diffuser ac systems , camc for 5th year after 2 years guarantee for ductable split type jet diffuser ac systems , camc for 6th year after 2 years guarantee for ductable split type jet diffuser ac systems , camc for 7th year after 2 years guarantee for ductable split type jet diffuser ac systems , sitc of 10hp vrf rotary inverter compressor with cooling only function including refrigerent r410a as required , sitc of 2 tr 4way cassette type units by modification of existing ceiling , sitc of 1 and a half tr 4 way cassette type units by modification of existing ceiling , sit