Web Analytics Made Easy - StatCounter

Raising Main Laying Tenders

Get complete information related to latest Raising Main Laying Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Raising Main Laying Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Raising Main Laying Tenders .

Filter
Loading....
Loading....
Loading....
Loading....
Loading....

Bid Submission Date Range
Tender Value

State Government

CTN :40955361 Due date: 19 Jul, 202519 Jul, 2025 39.45 Lacs
Tender For improvement of water pressure / supply in vijay park and adjoining area by laying a new water pipe line from noor - e -ilahi road to durga gali vijay park in ac -67

State Government

CTN :40972071 Due date: 26 Jul, 202526 Jul, 2025 28.30 Lacs
Tender For laying of new sewer line by p/l 400mm dia dwc pipe from b-223 to d/60, gandhi market road, hari nagar ward no-099 of ac-28 under ee(d)-82.

State Government

CTN :40950747 Due date: 18 Jul, 202518 Jul, 2025 1.77 Crore
Tender For supply, installation, testing and commissioning of 2 no. chillers with cooling tower in central ac plant of main hospital at skims soura - sitc of vfd based, ahri/ eurovent certified, water-cooled, mono/ twin screw type chiller of capacity not less than 100 tr with allied items. the item shall be complete and ready to be connected with main headers in the existing central air conditioning plant of skims soura. the chiller shall be accompanied with microprocessor based control panel with all safety, switch gears needed for safe, smooth and hassle-free operation. the job includes laying of foundation as per oem recommendation which shall be not less than 6 inches above the finished floor level. the technical specifications are further detailed in annexure b., sitc electric-motor driven centrifugal pump for condenser and chiller sides having a discharge of 15 to 18 litres per second, head of 30 metres, 1450 rpm. the technical specifications are furhter detailled in annexure b., insulated chilled water piping (nitrile rubber insulation)supplying, laying/ fixing, testing and commissioning of following nominal sizes of chilled water piping inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with following closed cell elastometric nitrile rubber of minimum 45 kg/ cum density, thermal conductivity 0.037 w/mk or better at 20 deg mean temperature class o insulation applied by suitable adhesive complete including repairing of damage to building etc. as per specifications and as required complete in all respect.note: the pipes of sizes 150mm & below shall be m.s. c class as per is: 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per is: 3589, from minimum 6.35mm thick m.s. sheet for pipes upto 350 mm dia., 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulationthickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulation thickness), 100 mm (32mm nitrile insulationthickness), 80 mm (32mm nitrile insulation thickness), 65 mm (32mm nitrile insulationthickness), sitc of butterfly valves with di body double flanged construction with epdm coated disc with long pitch and pn 16 pressure rating as per is 13095 (1991), 250 mm , 150 mm , 125 mm , 100 mm , 80 mm , 65 mm , providing and fixing of aluminum cladding of 0.63 mm thick sheet to the insulated pipelines including bends, valves, fittings, etc. the job includes grooving, providing and fixing of screws, washers etc. as per is : 2676 - 1981, 300 mm (32mm nitrile insulation thickness), 250 mm (32mm nitrile insulation thickness), 150 mm (32mm nitrile insulationthickness), 125mm (32mm nitrile insulationthickness), 100 mm (32mm nitrile insulation thickness), 80 mm (32mm nitrile insulationthickness), 65 mm (32mmnitrile insulation thickness), sitc of ductile iron non-return valve of following size with allied jobs as per site requirement. the valve shall be conforming to is-5312. pressure rating : pn16, 150 mm , 125 mm , 100 mm , sitc of y-strainer (ci) flanged end, of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , 100 mm , 80 mm , sitc of balancing valve (ductile iron) of following size with allied jobs as per site requirement. pressure rating : pn16, 150 mm , 125 mm , sitc of t-strainer (c.i.) of following size with allied jobs as per site requirement. pressure rating : pn16, 250mm , sitc of fully stainless steel pressure gauge (bourdon beryllium copper, socket ss316l, case and bazel ss304), rugged construction with epdm blowback, safety glass. 0-40 kg/cm , dual display bar/psi or selectable, sitc in position the bi-metal dial thermometer temperature guage 4 dail size bsp (m) connection, ss case and ss wetted parts completer as required, sitc of air release valve of following size. air release valves shall be provided at all higher points in piping system for venting., 25 mm dia , sitc

Central Government/Public Sector

CTN :40964005 Due date: 15 Jul, 202515 Jul, 2025 32.80 Lacs
Tender For supply of sitc of 1.5 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 1.5 tr split ac , sitc of 2 tr 5 star wall mount split ac , supply and fixing of extra copper refrigerant piping for 2 tr split ac , supply and fixing of 25 mm dia u pvc plumbing drain pipes , sitc of 4 tr floor mounted tower ac , supply and filling of extra refrigerant gas non cfc r32 or r410a , supply and fixing of 32 mm nominal dia rigid upvc drain water piping , making provision of hole in wall rcc cc of 100 mm dia to 150 mm dia , supply of 4c x 2.5 sq mm pvc insulated pvc sheathed stranded copper cable , supply of 4c x 6 sq mm copper conductor power cable , supply of 4c x 25 sq mm copper conductor power cable , laying and fixing of cable , supply installation testing and commissioning 15.9 mm o.d. insulation 13 mm thick suction pipe , supply installation testing and commissioning 9.5 mm o.d. insulation 13 mm thick discharge pipe , supplying and fixing of 12 way double door vtpn mcb db , supplying and fixing 3 pole 32 a rating, 415 v, 10 ka mcb , sitc of 200a, 36ka, 4 pole mccb in the existing vtpn mcb db , providing, fabrication and fixing of approved color painted ms cage or ms mesh or ms jali , providing, fabrication and fixing of painted ms stand for outdoor unit

CTN :40963414 Due date: 10 Jul, 202510 Jul, 2025 7.80 Lacs
Tender For rawalwas khurd dnit for laying of pipe line in place of old ac pvc pipe lines and balance in the streets in village rawalwas khurd and dhiranwas distt. hisar providing installing of raw water pumping machinery panel board construction of

State Government

CTN :40936541 Due date: 16 Jul, 202516 Jul, 2025 29.59 Lacs
Tender For providing and laying of 400/300 mm dia dwc sn 8 pipe from h. no. 46 to h. no. 267 in vp block, pitampura, shalimar bagh ac-14 under ee (d)-61.

State Government

CTN :40936555 Due date: 16 Jul, 202516 Jul, 2025 32.16 Lacs
Tender For providing and laying of 300 mm dia dwc sn 8 pipe from h. no. 13/42 to h. no. 01, h. no. 115 to 124, h. no. 137 to 125 in tp block, pitampura ward no. 57, shalimar bagh ac-14 under ee (d)-61.

corporations/Associations/Others

CTN :40929682 Due date: 12 Aug, 202512 Aug, 2025 NA
Tender For supply installation and commissioning of it hardware for establishment of lms-erp in government higher education institutions - annexure 13 price bid, desktop 1, desktop 2, laptop, desktop printer, multi function printer cum copier, a3 overhead scanner, 600va ups, 10kva online ups, lan for 655 sites, 9u wall mount rack, power strip 3 pin 5a & 6 socket, 90 cfm fans, 115~240v ac fan for above racks, 1u cable manager, cat 6 cable 4 pair utp cable, cat 6 key stone i/o, eia/tia-568-c certified, shuttered flush mount face plate dual socket, back box for face plate, cat 6 utp stranded copper wire, eia/tia- 568-c certified - 1m factory crimped patch cord, cat 6 utp stranded copper wire, eia/tia- 568-c certified -2m factory crimped patch cord, 32mm casing and capping for data cabling, smart managed 24 ports switch, cat 6 - 24 port fully loaded shuttered patch panel with built-in rear cable manager, eia/tia - 568-c complied, wlan materials required for 2 sites, 9u wall mount rack, power strip 3 pin 5a & 6 socket, 90 cfm fans, 115~240v ac fan for above racks, 1u cable manager, cat 6 cable 4 pair utp cable, cat 6 utp stranded copper wire, eia/tia - 568-c certified 1 m factory crimped patch cord, casing and capping for data cabling, l2 managed 24 ports sfp switch, enterprise wi-fi 6 wireless wall / ceiling mount access point 1800 mbps throughput, enterprise wireless controller, ap license per device, l2 managed 24 ports poe switch, cat 6 - 24 port fully loaded shuttered patch panel with built-in rear cable manager, eia/tia- 568-c complied, 48 port liu fully loaded - sm, 6 port liu fully loaded - sm, 6 core sm fiber cable, lc-lc sm fiber patch cord 3 mtr, 1 gig sm sfp module, 1" hdpe pipe with laying, 1 kva online ups 60 min back up

Central Government And Public Sector

CTN :40702670 Due date: 08 Jul, 202508 Jul, 2025 5.14 Lacs
Tender For corrigendum : supply of ems repair at bsnl tele bhavan ahmedabad f f - replace 4 ft 36 w t rod , replace 4 ft 18w led , replace 4 ft 230 v tl starter , replace electronic choke for tl , replace side holder for tl , replace 5 amp piano switch , replace 15 amp piano switch , replace 5 amp modular switch , replace 15 amp modular switch , replace 5 amp socket outlet 3pin , replace 15amp socket outlet 3pin , replace 5 amp modular outlet 3pin , replace 15 amp modular outlet , replace 2 module electronic regulator , replace 9w led lamp , rewinding 0.5hp monoblock pump , rewinding 10 hp monoblock pump , pvdg skilled technician , wiringfor l powerwith4sqmm cu , wiring with1.5qmmfrlscuwire , wiringwith4.0sqmmfrlscuwire , sdrg 1no 1.5 sq.mm frls cu wire , s drg 2no 1.5 sq.mm frls cu wire , sdrg 2no 4.0 sq.mm frls cu wire , sf 20mm pvc conduit , sl 2c 6 sq mm xlpe al cable , sl 4c 10 sq mm xlpe al cable , laying cable upto 35sqmm , laying cable 35to95sqmm , laying cable 95sqmm to 185sqmm , endtermi2c6.0sqmm cable , endtermi4c10sqmm cable , endtermi3.5c35sqmm cable , sf 32atpn mcb , sf 40atpn mcb , sf 63atpn mcb , sf 5 to 32a sp mcb , sf 5 to 32a spn mcb , sf 40a dp rccb spn , sf 40a 4p rccb tpn , sf 63a 4p rccb tpn , repalce sreet light with 25 w led in holder , repalce sreet light 25 w led on pole , repalce pvc box , replace heat detector fda system , replace smoke detector fda system , replace mcp fda system , replace ri fda system , replace ri of sounder fda system , refill fire extgshr 4.5kgs , pvdg hosepipe for fire extgshr 4.5kgs , sf 12v 26ah battery fda system , rpair card of fda panel , repair hooter of fda system , repair mcp of fda system , repair ri of fda system , repair pa amplifier of fda system , repair mike of pa fda system , conduct fire drill for bldg , serice 11kv 400a id substation , filteration mineral oil , servicing mv and lt panels incl all , calibartion relays by inj method , replacement 2a hrc fuselink , replacement 63a hrc fuselink , replacement 125a hrc fuselink , replacement 200a hrc fuselink , service of dg set 250 kva , service radiator for ea set 250 kva , supply smps battery charger 10a , sf 12v 130ah battery for ea set , supply brass battery terminals , sf led indi lamps 220 v ac , sfixing bradided fuel pipe for ea , replace blower motor for sac unit , replace blower drum for sac unit , replace condenser motor for sac unit , replace condenser blade for sac unit , replace pcb for ac indoor unit , replace pcb for ac outdoor unit , replace rotary compressor for sac unit , replace 25to35 5 mdf capacitor for ac , replace 25a 2p contactor for ac , replace term box for ac , water service for ac unit , blower service for ac unit , leak test and r22 r 410 gas charge for ac unit , replace 50mm thick filter , sf micro controller for ac unit , replace 25a spn mcb , site visit for ac repair

Central Government And Public Sector

CTN :40140601 Due date: 08 Jul, 202508 Jul, 2025 5.53 Lacs
Tender For corrigendum : supply of call base ems repair at bsnl oa himatnagar - attending fault at te below 25 km , attending fault at te 25 to 50 km , attending fault at te more than 50 km , sf 12v 88ah battery , sf 12v 130ah battery , sf 10amp 12v smps battery charger , repair smps battery charger , service of dg set 40 to 62.5kva , service of dg set 100 to 125kva , service of dg set 320 kva , 320 kvadg set starter repair , calibration of fuel pump and nozzle , service radiator for ea set upto 125 kva , service radiator for ea set upto 160 to 320 kva , rewinding 3 to 5 hp mono water pump , dol starter for 5 hp motor , repalce sreet light with 25 watts led lamp in holder , repalce sreet light with 25 watts led lamp on pole , repalce pvc box , sf 4 ft 20 w white led tl , sf 3 c 2.5 sq mm cu cond cable , sf 3 c 1.5 sq mm cu cond cable , laying xlpe cable upto 35 sq mm , end termination for 4c 10 sq mm cable , dismental ac unit incl all , shifting of 1.5 tr sac unit incl all , itc of 1.5 or 2 tr split ac units , charging r 32 or r410 gas for sac , charging r 407 gas for sac , sf add copper pipe with cable for sac , sf25 mm pvc isi drain pipe , disemntaling all ems , servicing mv and lt panels incl all , repalce 400 a mccb incl shift and itc
 Loading, Please wait...

Connect us via What's Up