Get complete information related to latest Reactor Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Reactor Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Reactor Tenders.
Tender For supply of bottom cover along with inspection cover for hood for smoothing reactor type sl- 42 to clw drg.no. 05/1/50/441 alt-6. [ warranty period: 30 months after the date of delivery ]
Tender For providing and fitting of safety devices at various water supply schemes of jal shakti (phe) mechanical rural division srinagar - providing, installation, testing and commissioning of power supply monitoring device for the protection of motors of reputed make to be installed at various water supply schemes of rural sub-division srinagar. (rest technical specifications as per annexure"a"), providing and fitting of thermal overload relays of type mn with following features:. built-in single-phase protection. manual and auto reset mode. confirms is/iec 60947-4-1 & iec60947-4-1the job includes fixing of the relay to the system and includes the cost on account of all accessories required for carrying out the said job. once connected the system is to be tested on load., relay range 45-75 a, relay range 66-110 a
Tender For dc-dc converter for dispatcher of 3s02 thales afc gate used in thales 3s02 afc gat e dispatcher for power supply. 1. specifications- 24v dc to 12v dc converter module. 1.1 make-la mda/cosel. 1.2 model- lambda pp25-24-12, cosel zus252412, 1.3 input voltage-18v to 36v dc. 1.4 output voltage-12v dc, output current-2.1a,output power=25.2w. 1.5 single output dc convertor with ultra thin profile-h-8mm, l-65mm, w-50mm. 1.6 terminal assignments: 1.6.1 input: pin*1 +v, pin*2 -v , pin*3 cnt. 1.6.2 output: pin*4 +v, pin*5 -v, pin*6 trm. 1.7 case: copper (thickness 0.4m m). 1.8 operating temperature -20 to +71 degreec. 1.9 convection cooling, isolation between input and output, overload voltage & overload current protection. 1.10 warranty-minimum one year. note: - 2. actual size, dimensions and fitment of supplied item must be "compatible" with the existing th ales 3s02 afc gates of dmrc in all respects. 3. vendor is required to mandatorily demonstrate/ sa mple test of the proposed items within 10 days from the date of award of loa/po for the functionalit y & compatibility with the existing thales 3s02 afc gates. 4. vendor is to provide the datasheets of the proposed items clearly depicting the technical details such as given below at the time of bid sub mission for technical evaluation. 4.1 make & model of the offered item. 4.2 specifications/ part no. w .r.t. its of supplied item. 4.3 all technical specs as per point 1 above. 5. vendor is to provide the "spe cifications compliance certificate" on their company's official letterhead as part of bid submission. 6. the supplied material must be compatible with existing system of dmrc in all respects. ]
Tender For dc-dc converter for dispatcher of 3s02 thales afc gate used in thales 3s02 afc gat e dispatcher for power supply. 1. specifications- 24v dc to 12v dc converter module. 1.1 make-la mda/cosel. 1.2 model- lambda pp25-24-12, cosel zus252412, 1.3 input voltage-18v to 36v dc. 1.4 output voltage-12v dc, output current-2.1a,output power=25.2w. 1.5 single output dc convertor with ultra thin profile-h-8mm, l-65mm, w-50mm. 1.6 terminal assignments: 1.6.1 input: pin*1 +v, pin*2 -v , pin*3 cnt. 1.6.2 output: pin*4 +v, pin*5 -v, pin*6 trm. 1.7 case: copper (thickness 0.4m m). 1.8 operating temperature -20 to +71 degreec. 1.9 convection cooling, isolation between input and output, overload voltage & overload current protection. 1.10 warranty-minimum one year. note: - 2. actual size, dimensions and fitment of supplied item must be "compatible" with the existing th ales 3s02 afc gates of dmrc in all respects. 3. vendor is required to mandatorily demonstrate/ sa mple test of the proposed items within 10 days from the date of award of loa/po for the functionalit y & compatibility with the existing thales 3s02 afc gates. 4. vendor is to provide the datasheets of the proposed items clearly depicting the technical details such as given below at the time of bid sub mission for technical evaluation. 4.1 make & model of the offered item. 4.2 specifications/ part no. w .r.t. its of supplied item. 4.3 all technical specs as per point 1 above. 5. vendor is to provide the "spe cifications compliance certificate" on their company's official letterhead as part of bid submission. 6. the supplied material must be compatible with existing system of dmrc in all respects. ]
Tender For design, engineering, manufacture, quality surveillance, testing at suppliers works, transportation, supply on for destination basis, retrofit, erection, testing and commissioning of plant scada, distributed control system(dcs), control and protection system, metering, synchronizing for all units including supply, laying, testing, termination of cables and networking, communication of ewly supplied and existing system, dismantling of existing panels & cables, etc. for nagjhari, kadra, kodasalli and supa power houses of kpcl
Tender For functional testing operation maintenance submission of report for isi of reactor pressure vessel and its internals and steam generators at kknpp 1 and 2