Get complete information related to latest Rectifier Repair Tenders . from India at Classic Tenders. Search the best available tenders from Indian government tenders, domestic Rectifier Repair Tenders , private tenders, online tenders, tender invitation notice, business tender notices, online tenders and bidding Rectifier Repair Tenders.
Tender For bid to ras corrigendum : providing of repair and overhauling service - repair of rectifier; repair of rectifier; yes; buyer premises,repair and overhauling service - repair of frequency convertor; repair of frequency convertor; yes; buyer premises,repair and overhauling service - repair of ac dc gpu; repair of ac dc gpu; yes; buyer premises
Tender For corrigendum : repair maintemance of ups automatic transformer switches apfc panel change over switches and other miscellaneous repairs at afs yelahanka
Tender For supply, installation, testing & commissioning of microprocessor based digital automatic karl fischer titration system for coulometric determination of water content in insulating oil of main transformer & gr of electric locomotives as per els/bza technical specifications no. b/trs/spec/4/238, sheets 1, 2, & 3.
Tender For corrigendum : custom bid for services - repair and maintenance of ac modules dc modules and various pcbs of all departmental drilling rigs of ongc tripura asset-work includes but not limited to supply of men, materials, testing equipment / tools etc for fault finding (trouble shooting), repairing, calibration and functional testing of ac modules, dc modules and various pcbs in e1400 series drilling rigs of tripura asset. broad details of the activities to be carried out are as below: a. following jobs are to be carried out in pcbs i. physical checking of healthiness of components & cleaning of the pcbs. ii. checking of voltages at different points in the pcbs after powered up through simulator. iii. replacement of faulty components, limited to 50% cost of the pcb, to make it operational. iv. calibration of pcbs v. on load testing of 12 hrs. continuous loading for satisfactory operational vi. fixing of pcbs in the respective panels b. following jobs are to be carried out in ac module i. visual inspection of module for any loose hardware & cleaning of the module. ii. checking of circuit by using simulator. iii. checking of over frequency tripping. iv. checking of under frequency level. v. under frequency voltage cut back test vi. idle-run ramp and idle trip test vii. throttle regulation check viii. master slave and command circuits check ix. current demodulator check x. automatic voltage regulator check xi. meter circuit check xii. over voltage trip check xiii. reverse power trip check xiv. frequency demodulator check xv. module panel meter check xvi. replacement of faulty components, limited to 50% cost of the ac module, to make it operational. xvii. on load testing of 12 hrs. continuous loading for satisfactory operational xviii. fixing of ac modules in the generator panel c. following jobs are to be carried out in dc-module i. visual inspection of module for any loose hardware & cleaning of the module. ii. dead band and current limit calibrations iii. zero throttle interlock circuit test iv. firing circuit test v. speed feedback circuit test vi. power limit circuit test vii. slave circuit test viii. manual voltage circuit test ix. over current trip calibration test x. meter circuit check xi. replacement of faulty components, limited to 50% cost of the dc module, to make it operational. xii. on load testing of 12 hrs. continuous loading for satisfactory operational xiii. fixing of dc modules in the dcpcr panel d. following jobs are to be carried out in battery charger i. visual inspection and cleaning of components such as transformer, voltmeter, ammeter, pcbs, rectifier, indication lamps and tightening of loose hardware, if any. ii. checking of tripping logics, dc under voltage, dc over voltage, reverse polarity, ac mains fail, over current, over temperature etc. iii. replacement of faulty components, limited to 50% cost of the battery charger, to make it operational.-msme exemption - no | startup exemption - no
Tender For corrigendum : repairing and testing of bgp failed distribution transformer capacity 25 kva to 200 kva with and without design supply and installation of automatic on off dtr protection device
Tender For corrigendum : supply of spares for ece make elevators installed in main plant for unit 5 and 6 csctpp, chhabra - a. common items, rccb 32 amp 3 pole for controler, cop single digit display with pcb, cop double digit display with pcb, transformer 500va input415 output 220/90/20 volt, brake liners for tm 40 machine (set), lop button up with pcb industrial type, lop button dn with pcb industrial type, lop set up and down industrial type (size 287mm x 98mm), lop set up and dn with pcb slim type (size 287mm x 98mm), lop button up with pcb slim type, lop button dn with pcb slim type, lop double digit pcb, lop single digit display with pcb, cop button slim type mark g, 1,2,3, do dc button industrial type, do dc button slim type, fan switch industrial type, fan switch slim type, auto / attendant key switch slim type, door track roller size 48 mm dia and 14 mm, eccentric roller size 48 mm dia and 14 mm, door beak roller size 48 mm dia and 14 mm, door guide shoe, reed switch fin type, door sensor complete set, dbr for 15 kw vfd, guide shoe liner - 16 mm, guide shoe liner - 10 mm, cwt guide shoe - 10 mm, alarm pcb complete set, coupler sket lh csk-vf00.ci000 skate set automatic horizontal sliding car door model 40/10 vf, capacitor 470 mfd, d locking key, magnet brake coil ( type: tmb-490, volt 80 dc,amp: 3.6a insu;lation type: class f), fermator motor drive (make:- fermator, model no:- cvf-vf4ac0000), fermator motor (make: fermator,type 125/40, model: yvp90-6s voltage 230v, freq: 50hz rpm: 900), fermator door drive belt, car fan dia 300 mm, car fan grill size 365 x 365 mm, door lock contact male and female (make:- fermator, model no:-005546, 1a, 230 vac, 50/60 hz, 200vdc ), limit switch with lever roller type with no/nc contact limit switch 2 amp and 110 dc, door drive pulley (single teeth), synchrimision rope, bmo pcb, vmvf2 card, pfard card, vfvr2b assy card, apcld card, apex-1 card, apex-2 card, ard for 4 floor, car door track 800 mm opening, car door track 1000 mm opening, landing door track 800 mm opening, landing door track 1000 mm opening, osg 8mm rope breaking strength of rope 69kn desighn factor of safety 13.98, osg set for 8mm rope, osg set for 6mm rope, b. service building lift requirement (nrj 2630), vfvr1 card, inverter board for adcon ard, kds controller mother board, c. boilrt-5 lift requirement(nrj 2434), coupler sket rh, ard for 11 floor, controller card, d. boilrt-6 lift requirement(nrj 2435), bridge rectifier 3512, arl-300 lite card, fixed contact assy. 1a/110 v, moving contact assy 1a/110 v, concentric roller fermator, cam arrangement (pickup) pm lh fermator( lh rh coupler), micro switch mtpc-27, fermator motor, reed switch pencil type with led, fermator door driver belt, ard for 11 floor, e. jnt-1 lift (g+3), vfvr1 card, inverter board for adcon ard, kds controller mother board, coupler sket rh, ard for 4 floor, reed switch pencil type, f. sch-1 lift (g+6), vfvr1 card, inverter board for adcon ard, kds controller mother board, coupler sket rh, ard for 7 floor, reed switch pencil type, g. jnt-21 lift (g+3), controller for g+3, cop for g+3, lop, normal inspection box, reed switch, limit cut angle, magnet, vfd main drive, h. sch-21 lift (g+6), controller for g+6, cop for g+6, lop, normal inspection box, reed switch, limit cut angle, magnet, vfd main drive
Tender For corrigendum : supply of spares for ece make elevators installed in main plant for unit 5 and 6 csctpp, chhabra- rccb 32 amp 3 pole for controler, cop single digit display with pcb, cop double digit display with pcb, transformer 500va input415 output, 220/90/20 volt, brake liners for tm 40 machine (set), lop button up with pcb industrial type, lop button dn with pcb industrial type, lop set up and down, industrial type (size 287mm x, 98mm), lop set up and dn with pcb slim, type (size 287mm x 98mm), lop button up with pcb slim type, lop button dn with pcb slim type, lop double digit pcb, lop single digit display with pcb, cop button slim type mark g, 1,2,3, do dc button industrial type, do dc button slim type, fan switch industrial type, fan switch slim type, auto / attendant key switch slim type, door track roller size 48 mm dia and 14, mm, eccentric roller size 48 mm dia and 14, mm, door beak roller size 48 mm dia and 14, mm, door guide shoe, reed switch fin type, door sensor complete set, dbr for 15 kw vfd, guide shoe liner - 16 mm, guide shoe liner - 10 mm, cwt guide shoe - 10 mm, alarm pcb complete set, coupler sket lh csk-vf00.ci000 skate set, automatic horizontal sliding car door, model 40/10 vf, capacitor 470 mfd, d locking key, magnet brake coil ( type: tmb-490,, volt 80 dc,amp: 3.6a insu;lation type:, class f), fermator motor drive (make:- fermator,, model no:- cvf-vf4ac0000), fermator motor (make: fermator,type, 125/40, model: yvp90-6s voltage, 230v, freq: 50hz rpm: 900), fermator door drive belt, car fan dia 300 mm, car fan grill size 365 x 365 mm, door lock contact male and female, (make:- fermator, model no:-005546, 1a,, 230 vac, 50/60 hz, 200vdc ), limit switch with lever roller type with, no/nc contact limit switch 2 amp and, 110 dc, door drive pulley (single teeth), synchrimision rope, bmo pcb, vmvf2 card, pfard card, vfvr2b assy card, apcld card, apex-1 card, apex-2 card, ard for 4 floor, car door track 800 mm opening, car door track 1000 mm opening, landing door track 800 mm opening, landing door track 1000 mm opening, osg 8mm rope breaking strength of rope, 69kn desighn factor of safety 13.98, osg set for 8mm rope, osg set for 6mm rope, service building lift requirement (nrj, vfvr1 card, inverter board for adcon ard, kds controller mother board, boilrt-5 lift requirement(nrj, coupler sket rh, ard for 11 floor, controller card, boilrt-6 lift requirement(nrj, bridge rectifier 3512, arl-300 lite card, fixed contact assy. 1a/110 v, moving contact assy 1a/110 v, concentric roller fermator, cam arrangement (pickup) pm lh, fermator( lh rh coupler), micro switch mtpc-27, fermator motor, reed switch pencil type with led, fermator door driver belt, ard for 11 floor, jnt-1 lift (g+3), vfvr1 card, inverter board for adcon ard, kds controller mother board, coupler sket rh, ard for 4 floor, reed switch pencil type, sch-1 lift (g+6), vfvr1 card, inverter board for adcon ard, kds controller mother board, coupler sket rh, ard for 7 floor, reed switch pencil type, jnt-21 lift (g+3), controller for g+3, cop for g+3, lop, normal inspection box, reed switch, limit cut angle, magnet, vfd main drive, controller for g+6, cop for g+6, lop, normal inspection box, reed switch, limit cut angle, magnet, vfd main drive